LC1D115gp TeSys
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 115A, 24VDC, Standard Coil

Catalogue Number: LC1D1156BD
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
LC1D115gp TeSys
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
CONTACTOR 115A 1F+1O 24V DC 3P+1F+1O CO
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • motor control
  • resistive load
    • Utilisation category
    • AC-3
    • AC-1
    • AC-4
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 1000 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 30 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 55 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 59 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 75 kW at 500 V AC 50/60 Hz (AC-3)
          • 80 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 65 kW at 1000 V AC 50/60 Hz (AC-3)
          • 18.5 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
            • 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                DC standard
                [Uc] control circuit voltage
                24 V DC
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                8 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
                200 A (at 60 °C) for power circuit
                Irms rated making capacity
              • 1260 A at 440 V for power circuit conforming to IEC 60947
              • 140 A AC for signalling circuit conforming to IEC 60947-5-1
              • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • Rated breaking capacity
                  1100 A at 440 V for power circuit conforming to IEC 60947
                  [Icw] rated short-time withstand current
                • 250 A 40 °C - 10 min for power circuit
                • 550 A 40 °C - 1 min for power circuit
                • 950 A 40 °C - 10 s for power circuit
                • 1100 A 40 °C - 1 s for power circuit
                • 100 A - 1 s for signalling circuit
                • 120 A - 500 ms for signalling circuit
                • 140 A - 100 ms for signalling circuit
                  • Associated fuse rating
                  • 250 A gG at <= 690 V coordination type 1 for power circuit
                  • 200 A gG at <= 690 V coordination type 2 for power circuit
                  • 10 A gG for signalling circuit
                    • Average impedance
                      0.6 mOhm - Ith 200 A 50 Hz for power circuit
                      [Ui] rated insulation voltage
                    • power circuit: 600 V CSA certified
                    • power circuit: 600 V UL certified
                    • power circuit: 1000 V conforming to IEC 60947-4-1
                    • signalling circuit: 690 V conforming to IEC 60947-1
                    • signalling circuit: 600 V CSA certified
                    • signalling circuit: 600 V UL certified
                      • Electrical durability
                      • 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
                      • 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
                        • Power dissipation per pole
                        • 24 W AC-1
                        • 7.9 W AC-3
                          • Protective cover
                            with
                            Mounting support
                          • rail
                          • plate
                            • Standards
                            • CSA C22.2 No 14
                            • EN 60947-4-1
                            • EN 60947-5-1
                            • IEC 60947-4-1
                            • IEC 60947-5-1
                            • UL 508
                              • Product certifications
                              • GOST
                              • CCC
                              • RINA
                              • CSA
                              • UL
                              • BV
                              • GL
                              • LROS (Lloyds register of shipping)
                              • DNV
                                • Connections - terminals
                                • control circuit: lugs-ring terminals (external diameter: 8 mm)
                                • power circuit: lugs-ring terminals (external diameter: 25 mm)
                                • power circuit: bars 1 cable(s) - busbar cross section: 5 x 25 mm
                                  • Tightening torque
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
                                  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
                                  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
                                  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
                                    • Operating time
                                    • 20...35 ms closing
                                    • 40...75 ms opening
                                      • Safety reliability level
                                      • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                      • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                        • Mechanical durability
                                          8 Mcycles
                                          Maximum operating rate
                                          1200 cyc/h 60 °C
                                          Coil technology
                                          with integral suppression device
                                          Control circuit voltage limits
                                        • operational: 0.75...1.2 Uc DC (at 55 °C)
                                        • drop-out: 0.15...0.4 Uc DC (at 55 °C)
                                          • Time constant
                                            25 ms
                                            Inrush power in W
                                            270-365 W (at 20 °C)
                                            Hold-in power consumption in W
                                            2.4-5.1 W at 20 °C
                                            Auxiliary contacts type
                                          • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                          • type mirror contact 1 NC conforming to IEC 60947-4-1
                                            • Signalling circuit frequency
                                              25...400 Hz
                                              Minimum switching current
                                              5 mA for signalling circuit
                                              Minimum switching voltage
                                              17 V for signalling circuit
                                              Non-overlap time
                                            • 1.5 ms on de-energisation between NC and NO contact
                                            • 1.5 ms on energisation between NC and NO contact
                                              • Insulation resistance
                                                > 10 MOhm for signalling circuit
                                                Contact compatibility
                                                M10
                                                Compatibility code
                                                LC1D
                                                IP degree of protection
                                                IP20 front face conforming to IEC 60529
                                                Protective treatment
                                                TH conforming to IEC 60068-2-30
                                                Pollution degree
                                                3
                                                Ambient air temperature for operation
                                                -5-60 °C
                                                Ambient air temperature for storage
                                                -60-80 °C
                                                Permissible ambient air temperature around the device
                                                -40-70 °C at Uc
                                                Operating altitude
                                                3000 m without
                                                Fire resistance
                                                850 °C conforming to IEC 60695-2-1
                                                Flame retardance
                                                V1 conforming to UL 94
                                                Mechanical robustness
                                              • vibrations contactor open: 2 Gn, 5...300 Hz
                                              • vibrations contactor closed: 4 Gn, 5...300 Hz
                                              • shocks contactor closed: 15 Gn for 11 ms
                                              • shocks contactor open: 6 Gn for 11 ms
                                                • Height
                                                  158 mm
                                                  Width
                                                  120 mm
                                                  Depth
                                                  136 mm
                                                  Net weight
                                                  2.5 kg
                                                  Sustainable offer status
                                                  Green Premium product
                                                  REACh Regulation
                                                  Free of Substances of Very High Concern above the threshold
                                                  EU RoHS Directive
                                                  Compliant
                                                  Mercury free
                                                  Yes
                                                  RoHS exemption information
                                                  Yes
                                                  China RoHS Regulation
                                                  Product out of China RoHS scope. Substance declaration for your information
                                                  Environmental Disclosure
                                                  ENVPEP060301EN
                                                  Circularity Profile
                                                  ENVEOLI100405
                                                  WEEE
                                                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                  Warranty
                                                  18 months

                                                  Documents & downloads

                                                  hide show
                                                  Filter items
                                                  • All

                                                  • CAD Files and Packs

                                                  • Product Brochures

                                                  • Technical Data Catalogues

                                                  • End of Life Manual

                                                  • Installation Instruction

                                                  • Data Bulletin

                                                  • Product Environmental

                                                  • Certificates (MSDS)

                                                  • Declaration of Conformity

                                                  Frequently Asked Questions

                                                  hide show

                                                  What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                  Issue:
                                                  Identifying maximum voltage of an LC1D contactor

                                                  Product Line:
                                                  TeSys D Contactors

                                                  Environment:
                                                  IEC contactors and starters used in North America

                                                  Cause:
                                                  n/a

                                                  Resolution:
                                                  IThe maximum voltage per UL and CSA is 600VAC. 
                                                   

                                                  What is the difference between LC1D115 and LC1D1156?

                                                  The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


                                                   

                                                  What is the terminal shroud part number for a LC1D1156**

                                                  The part code is LA9D115703

                                                  Does the LC1D1156U7 come with 1NO & 1NC Aux contact

                                                  Yes - all the D range contactors have one of each aux contact

                                                  What replaces LC1D50BD

                                                  Replacement LC1D50ABD

                                                  What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

                                                  The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

                                                  https://www.schneider-electric.com.au/en/search/lx1d8n7


                                                   

                                                  What is the interlock to use with the lcd1156**

                                                   The interlock is LA9D11502

                                                  Are the D-Line contactors rated to break DC voltages?

                                                  Issue: 
                                                  Can the TeSys D line be used to control DC loads? 

                                                  Product Line:
                                                  Tesys D contactors

                                                  Environment:
                                                  Products sold and used in the United States
                                                   
                                                  Cause:
                                                   DC power circuit
                                                   
                                                  Resolution:
                                                   
                                                  Yes, 75 VDC (125 VDC for D115 & D150) per pole which means that through a four pole device breaking 300 VDC is possible by wiring all four power poles in series. However, be aware that the device current ratings will differ according to the number of poles in series and the type of application.

                                                  Devices are suitable but not UL Listed for DC applications.

                                                  More information on their DC ratings can be found in the current TeSys Motor Control and Protection Compentns catalog: https://www.schneider-electric.us/en/download/document/MKTED210011EN/


                                                   

                                                  What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

                                                  Issue:
                                                  LC1D115 / LC2D115 and LC1D150 / LC2D150

                                                  Product Line:
                                                  Tesys D line Contactors

                                                  Environment:
                                                  North America

                                                  Resolution:
                                                  The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

                                                  Note 1: LC1D150 contactors are only available with *7 coil codes.
                                                  Note 2: Coil Code ending number represents frequency rating as follows:
                                                  5 = 50 Hertz
                                                  6 = 60 Hertz
                                                  7 = 50/60 Hertz

                                                  AC Volts ___Code                DC Volts ___Code
                                                  24 ___ B5 or B6 or B7          12 ___ Not Avail.        
                                                  42 ___ D5 or D7                   24 ___ BD
                                                  48 ___ E5 or E6 or E7          36 ___ CD
                                                  110 ___ F5 or F6 or F7         48 ___ ED
                                                  115 ___ FE5 or FE7             60 ___ ND
                                                  120 ___ G6 or G7                72 ___ SD
                                                  127 ___ FC5 or FC7            110 ___ FD
                                                  208 ___ L6 or LE7               125 ___ GD
                                                  220 ___ M5 or M6 or M7       220 ___ MD
                                                  230 ___ P5 or P7                 250 ___ UD
                                                  240 ___ U5 or U6 or U7        440 ___ RD
                                                  277 ___ W6 or UE7                
                                                  380 ___ Q5 or Q6 or Q7                
                                                  400 ___ V5 or V7                
                                                  415 ___ N5 or N7                
                                                  440 ___ R5 or R6 or R7                
                                                  480 ___ T6 or T7                
                                                  500 ___ S5 or S7                


                                                   

                                                  What is the replacement for a LP1D1210BD

                                                  You can use a LC1D12BD or for low consumption a LC1D12BL.

                                                  What is the code for a contactor rated at 100A AC3 with a 240V AC coil ?

                                                  Code = LC1D1156U7 ( 3 Pole Contactor comes with 1 N/C + 1 N/O Auxilliary as a standard ) 

                                                  What is the difference between LA9D11569 and LA9D115691?

                                                  Issue:
                                                  Identifying differences between two part numbers

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Selecting between two similar part numbers

                                                  Resolution:
                                                  LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


                                                   

                                                  What is the 85A Overload to suit LC1D115* Contactor

                                                  85A Overload code for LC1D115* Contactor = LRD4365 

                                                  What is the difference between the LC1D1506N7 and the LC1D150N7?

                                                  The LC1D1506N7 can accept 5X25mm Bars aswell as Lugs or ring terminals. The LC1D150N7 only accepts cable lugs upto 120mm2.

                                                  Are replacement contacts available for LC1D115?

                                                  Issue:
                                                  Replacement contacts needed for 115 amp D line contactor

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Identifying part number to order replacement contact kit

                                                  Resolution:
                                                  Yes, order LA5D1158031 for 3 pole kit or LA5D115804 for 4 pole kit.


                                                  CTA-ID : 11125

                                                  Does the 150A IEC contactor LC1D150BD with a 24 volt DC coil have a coil suppressor built in?

                                                  Issue: 
                                                  Does the LC1D150 with a DC coil include suppression? 

                                                  Product Line:
                                                   Tesys D line contactors and accessories

                                                  Environment:
                                                  Products sold and used in the United States
                                                   
                                                  Cause:
                                                   Identifying components and accessories
                                                   
                                                  Resolution:
                                                   
                                                  Yes. Suppression is built into the 150A DC contactor coil.
                                                   

                                                  Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

                                                  Issue:
                                                  Can new accessories be used on older style contactors

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Identifying product compatibility

                                                  Resolution:
                                                  Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


                                                   

                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Issue:​
                                                  What is the altitude derating for a TeSys D-Line contactor?

                                                  Product Line:
                                                  Digest 177 Section 18 : Contactors and Starters, IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                  Voltage
                                                  3500m x 0.90
                                                  4000m x 0.80
                                                  4500m x 0.70
                                                  5000m x 0.60

                                                  Current
                                                  3500m x 0.92
                                                  4000m x 0.90
                                                  4500m x 0.88
                                                  5000m x 0.86

                                                  For example, an LC1D80 at 5000 meters:
                                                  - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                  - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                   

                                                  What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

                                                  LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

                                                  What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

                                                  Issue:
                                                  Identifying the difference between LAD4TB and LAD4TBDL

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Identifying the difference between two similar part numbers

                                                  Resolution:
                                                  The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


                                                   

                                                  What are the dimensional differences in the LC1D1810 and the LC1D18?

                                                  Issue:
                                                  What are the dimensional differences in the LC1D1810 and the LC1D18?

                                                  Product Line:
                                                  TeSys D Line Contactors

                                                  Environment:
                                                  All Product Lines

                                                  Cause:
                                                  Can not find the dimensions for obsoleted LC1D1810

                                                  Resolution:
                                                  Please see attached PDF for dimensions of the LC1D1810 and the LC1D18.

                                                  Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                  Issue:
                                                  Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                  Product Line: 
                                                  Tesys D Contactors

                                                  Environment:
                                                  IEC contactors

                                                  Resolution:
                                                  The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                   

                                                  Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

                                                  Issue:
                                                  Auxiliary contact modules for the LC1D and LC2D contactors

                                                  Product Line: 
                                                  Contactor and Starters - IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
                                                  Front Mounting; maximum of 1 block per contactor:

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------1---------LADN11-----------LA1DN11
                                                  --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
                                                  --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
                                                  --2-----------0---------LADN20-----------LA1DN20
                                                  --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
                                                  --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
                                                  --0-----------2---------LADN02-----------LA1DN02
                                                  --2-----------2---------LADN22-----------LA1DN22
                                                  --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
                                                  --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
                                                  --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
                                                  --3-----------1---------LADN31------------LA1DN31
                                                  --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
                                                  --1-----------3---------LADN13------------LA1DN13
                                                  --4-----------0---------LADN40------------LA1DN40
                                                  --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
                                                  --0-----------4---------LADN04------------LA1DN04




                                                  Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------0--------LADN10----------LA1DN10
                                                  --0-----------1--------LADN01----------LA1DN01

                                                  Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
                                                  (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

                                                  N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
                                                  --1-----------1--------LAD8N11----------LA8DN11
                                                  --2-----------0--------LAD8N20----------LA8DN20
                                                  --0-----------2--------LAD8N02----------N/A

                                                  Footnotes:
                                                  {1} EN50 012 Machine Tool Terminal Markings
                                                  {2} (2) NO Sealed Dust Tight Contacts
                                                  {3} Gold Flash Contacts
                                                  {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
                                                  {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
                                                  {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

                                                  What is the coil consumption or burden for the Tesys LC*D** contactors?

                                                  * 1 or 2
                                                  ** 09 through 38

                                                  Issue:
                                                  Coil consumption or burden for the Tesys LC1D/2D contactors from 9A - 38A

                                                  Product Line: 
                                                  Contactors and Starters - IEC

                                                  Environment:
                                                  North American Products

                                                  Resolution:
                                                  All AC coils for the LC1D09 through LC1D38 3-pole contactors ( including ring tongue, quick connect and spring terminal versions ) have an inrush of 70 volt-amps for either 50 or 60 Hertz applications, and a sealed value of 7 volt-amps for 50Hertz applications or 7.5 volt-amps for 60 Hertz applications.

                                                  Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

                                                  Issue:  
                                                  Tesys D enclosed starter with a DC control 

                                                  Product Line:
                                                   Enclosed Tesys D line starters

                                                  Environment:
                                                  North American Products
                                                   
                                                  Cause:
                                                  DC control circuit 
                                                   
                                                  Resolution:
                                                  Yes but limited to 24 VDC.

                                                  What is the complete part number for a 25A 11Kw 3P Contactor with 24VDC coil?

                                                  LC1D25BD is the correct part number

                                                  What is the color scheme of the Tesys D-Line contactors?

                                                  Issue:
                                                  Looking for different color scheme of the Tesys D-Line contactors.

                                                  Product Line:
                                                  Tesys D Contactors

                                                  Environment:
                                                  LC1D contactors

                                                  Resolution:
                                                  Beige and dark gray.
                                                   

                                                  Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                                  Issue:
                                                  Mounting adaptor for GV2 and LC1D contactor

                                                  Product Line:
                                                  Motor Starters and Protectors

                                                  Environment:
                                                  TeSys GV Manual Starter and Protectors
                                                  Tesys D Contactors
                                                   
                                                  Resolution:
                                                  The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                                  I have a LC1D12BD contactor and want to fit a LA4DFB to it

                                                   You need to use a LAD4BB adaptor

                                                  What is part number for terminal shrouds for LC1D1506U7?

                                                  The part number for terminal shrouds for LC1D1506 and LC1D1156 contactors is LA9D115703
                                                  User-added image

                                                  LA9D115703

                                                  Shrouds - for 3 poles TeSys model D

                                                  For furher information see:
                                                  https://www.schneider-electric.com.au/en/product/LA9D115703/shrouds---for-3-poles-tesys-model-d

                                                   

                                                  What is the Tesys D-Line maximum frequency for Power Poles?

                                                  Issue:
                                                  Checking on the maximum Hz voltage that can be applied to the Tesys D-line contactors.

                                                  Product Line:
                                                  Tesys D Contactors

                                                  Environment:
                                                  IEC Contactors and Starters

                                                  Cause:
                                                  Product Characteristics

                                                  Resolution:
                                                  These units have been tested for frequencies 25Hz to 400hz within the operational current of the device .  No testing has been done beyond this frequency.

                                                  Is 240 volt replacement control coil available for LC1D11500?

                                                  Issue:
                                                  Identifying replacement coil part number

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Replacement control coil needed for older style Tesys Contactor

                                                  Resolution:
                                                  Yes, order LX1D8U5 for 50 hertz, LX1D8U6 for 60 hertz or LX1D8U7 for 50/60 hertz. Average coil consumption is 300 VA inrush 22 VA sealed for 50 hertz, 300 VA inrush 22 VA sealed for 60 hertz and 280 to 350 VA inrush 2 to 18 VA sealed for 50/60 hertz.


                                                  CTA-ID : 11321

                                                  What are the stand alone short circuit current ratings on the LC1D** contactors?

                                                  Issue:
                                                  Tesys D SCCR

                                                  Product Line:
                                                  Contactors and Overload Relays

                                                  Environment:
                                                  TeSys™ D Contactors and Overload Relays
                                                   
                                                  Resolution:
                                                  The contactors have a stand alone withstand rating that has been established by UL and is based on the maximum horsepower rating for a given device. However, only combination type starters are supplied with short circuit protective devices having a short circuit current rating.

                                                  They are as follows:
                                                  Horsepower SCCR (A)

                                                  0 thru 1 1,000
                                                  1 thru 50 5,000
                                                  51 thru 200 10,000
                                                  201 thru 400 18,000
                                                  401 thru 600 30,000
                                                  601 thru 900 42,000
                                                  901 thru 1600 85,000
                                                  1601+ 100,000

                                                  Are there replacement dc coils available for LC1D12BD

                                                  They are not available as a spare part for the LC1D09-D38 Contactors
                                                   

                                                  Can the LC1D12BD be changed from a DC operated device to AC operation by changing the coil?

                                                  Issue:
                                                  Is it possible to swap AC coil to DC coil and vice versa on an LC1D12BD?

                                                  Product Line:
                                                  Tesys D Contactors

                                                  Environment:
                                                  LC1D12BD

                                                  Resolution:
                                                  No, the coil assemblies are not compatible nor can you replace the DC coils.
                                                   

                                                  What is the part number for the red safety cover to go on the LC1D contactors?

                                                  The LC1D09-65 take the LAD9ET1S
                                                  The LC1D80-95 take the LAD9ET3S 
                                                  The LC1D115-150 take the LAD9ET4S

                                                  Can a side mounted auxiliary be fitted to LC1D18BD?

                                                  No a side mounted auxiliary cannot be fitted to LC1D18BD.

                                                   

                                                  What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                  Issue:
                                                  Identifying power terminal lug data for the D2 style contactors

                                                  Product Line:
                                                  Tesys D line contactors

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Power terminal lug data required

                                                  Resolution:
                                                  For contactors with screw clamp terminals:
                                                  stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                  stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                  solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                  What is the part number for a 3 pole 115amp contactor with 240VAC coil?

                                                  The part number for a 3 pole 115amp contactor with 240VAC coil is - LC1D1156U7

                                                  For further information , visit link below:-
                                                  https://www.schneider-electric.com.au/en/search/LC1D1156
                                                  User-added image

                                                  Will the LAD4BB adapter work with a LC1D12BD contactor?

                                                  Issue:
                                                  Can we use the LAD4BB with the LC1D12BD?

                                                  Product Line:
                                                  IEC contactors and starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Identifying product compatibility

                                                  Resolution:
                                                  The LAD4BB will not work on the DC contactors, just the AC contactors.
                                                   

                                                  What is the part number for a 3 pole 18amp 24VDC coil contactor with front mounted auxiliary with 1 N/O & 1 N/C contact?

                                                  The part number for a 3 pole 18amp 24VDC coil contactor with front mounted auxiliary with 1 N/O & 1 N/C contact is - LC1D18BD & LADN11

                                                  For further information, visit the link below:-
                                                  https://www.schneider-electric.com.au/en/search/LC1D18BD
                                                  https://www.schneider-electric.com.au/en/search/LADN11
                                                  User-added image
                                                  User-added image

                                                  Are 48 volt AC replacement control coils available for LC2D1801?

                                                  Issue:
                                                  Checking if a 48 volt AC replacement coil is available for an LC2D1801.

                                                  Product Line:
                                                  Tesys D Contactors

                                                  Environment:
                                                  LC1D1810

                                                  Resolution:
                                                  This coil is obsolete. Replace the contactor with the new TeSys product, LC2D18E7. Note this is a functional equal only. Accessories for the old product may or may not fit the new design. Confirm dimensions.
                                                   

                                                  What is the part number for replacement contacts for the LC1D115 contactor??

                                                  The part number for replacement contacts for the LC1D115 contactor is - LA5D1158031
                                                  For further information on this part go to link below:-

                                                  https://www.schneider-electric.com.au/en/search/LA5D1158031

                                                  Does LC1D65AB7 3P (3 NO) TeSys Model D contactor have a normally opened and normally closed auxiliary contact?

                                                  What are the main DC power supply voltage and current ratings of LC1F115 & LC1F150 Contactors.

                                                  The LC1D115/150 was launched in 1996 in order to substitute the LC1F115/150 in the future, and offer better performances using an improved design.
                                                   
                                                  For this reason the characteristics of LC1F115 and LC1F150 were removed from most recent catalogues.
                                                   
                                                  Refer the attached data sheet for the specifications showing the DC characteristics and the details of the rated voltage & relevant current rating with the no. of poles in series.

                                                  Note: Use the attached sheet only for the LC1F115-150 contactor ratings as this is an old catalog sheet. For other rating contactors use the latest Technical Catalogue available on net (www.schneider-electric.com).

                                                  What is the replacement for LC1D115 with LX1D6G7 coil?

                                                  The replacement for LC1D115 with LX1D6G7 coil is LC1D1156F7

                                                  LC1D1156F7
                                                  TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 110 V AC 50/60 Hz coil

                                                  For more information see:
                                                  https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D1156F7

                                                  Where do I find the Coil voltage on the Tesys D 3 Pole AC Contactor?

                                                  On the Tesys D 3 Pole AC Contactor you will find the coil voltage marked at the top, behind the Power terminals of the Contactor, for example U7, 240V 50/60 Hz

                                                  For the DC Version, the coil voltage is marked on the front of the Contactor. Hence it has got complete part number for the Contactor on the front, for example: LC1D25BD for 24V DC Coil.

                                                  Are the LC1D115 and LC1D150 contactors din rail mountable?

                                                  Issue: 
                                                  LC1D115 and D150 mounting

                                                  Product Line:
                                                   Tesys D contactors

                                                  Environment:
                                                  Products sold and used in the United States
                                                   
                                                  Cause:
                                                  Din rail mounting desired for large D line contactor
                                                   
                                                  Resolution:
                                                   
                                                  Yes, they use 2-35mm din rails


                                                   

                                                  What is the mechanical interlock for the LC1D115 contactor?

                                                  Issue:
                                                  Interlock needed for a pair of LC1D115 contactors

                                                  Product Line:
                                                  NEMA combination starters

                                                  Environment:
                                                  Products sold and used in the United States

                                                  Cause:
                                                  Application requires mechanical interlocking

                                                  Resolution:
                                                  LA9D11502. It includes the electrical interlocks.

                                                   

                                                  What is the part code for terminal shrouds to fit LC1D115 or LC1D150

                                                  The part code is LA9D115703 for 3 pole
                                                  The part code for 4 pole is LA9D115704
                                                  Show More