Specifications

hide show
Range of product
TeSys D
Range
  • TeSys
  • Linergy
    • Device short name
      LAD9
      Product or component type
      kit for star-delta
      Poles description
      3P
      Range compatibility
      TeSys D
      Product compatibility
    • LC1D09
    • LC1D12
    • LC1D18
    • LC1D25
    • LC1D32
    • LC1D38
      • Kit composition
      • electrical and mechanical interlock
      • set of power connection
      • time delay contact block LAD S2
        • Net weight
          0.18 kg
          Compatibility code
          LAD9
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          REACh free of SVHC
          Yes
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          X
          Environmental Disclosure
          ENVPEP111213EN_V1
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Documents & downloads

          hide show
          Filter items
          • All

          • Movies

          • CAD Files and Packs

          • Product Brochures

          • Technical Data Catalogues

          • Installation Instruction

          • Product Environmental

          Frequently Asked Questions

          hide show

          What are the various parts included in the LAD91217 Star Delta connection kit?

          The different parts contained in the LAD91217 Star Delta connection kit is as shown in the attached figure.

           

          What does LAD93217 kit come with?

          What is the plastic arm for LE1D18U7 stop button

          Part code LAD91810

          Can you buy a spare gasket for a BALS1217

          No

          What is the operational Temperature for a LE1M35U705

           The operational temperature is  -5 to 40° Degrees celsius

          Difference between LAD9ET1 and LAD9ET1S

          Issue:
          What is the difference between the LAD9ET1 and the LAD9ET1S

          Product Line:
          TeSys D accessories

          Environment:
          US Product

          Cause:
          Neither of these parts are in the Digest

          Resolution:
          The S designates a red cover.  These covers are red to designate that the contactor is being used for a safety application or part of a safety circuit.  The part number without the S is for a standard replacement covers.

           

          Is there a white cover plate available for the PDL 699?

          Yes, the PDL 699CWH is the white cover plate to suit the PDL 699.
           

          What is the code for the Red Cover / Front panel for an LC1D contactor?

          LAD9ET1S suitable for  TeSys Contactors between 9A - 65 A  AC3 

          What is the part number for switchboard labels?

          The part number for switchboard labels is 4C15-6G (green labels) and/or 4C15-6R (red labels).

          For further information please visit https://www.clipsal.com/Trade/search-results?q=4C15-6
           

          Can you purchase spare door for NSYS3D10830P enclosure?

          No, doors for NSYS3D enclosures not sold as spares.

          NSYS3D10830P
          Spacial S3D plain door with mount.plate. H1000xW800xD300 IP66 IK10 RAL7035.

           

          What is the part number for a push button dimmer to suit the BSL Range?

          The part number for a push button dimmer to suit the BSL Range is a 31E2PUDM.

          Need the spare part code for a DOL starter LE1D12, only need the arm behind push button

           The part code is LAD9091

          What are the part codes for the red safety covers for TeSys D and U?

          The part codes are as follows:
          LAD9ET1S TeSys D 9Amp to 65Amp
          LAD9ET3S TeSys D 80Amp to 95Amp
          LAD9ET4S TeSys D 110Amp to 150Amp
          LADN22S for Aux contact blocks
          LU9ET1S for TeSys U
           

          What is the interlock for LCD18

           The part code is LAD9R1V

          What is the replacement stop button for LE1D12 DOL Starter?

          The replacement stop button for LE1D12 DOL Starter is ZB5AL432 + LAD9091
          +                                    
          ZB5AL432 
          red projecting pushbutton head Ø22 spring return "O" +      LAD9091 TeSys LE - adaptation kit for head of start and stop/reset pushbutton 

          For more information see;https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=ZB5AL432 + https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD9091
           

          Need a LC2D323U7 reversing contactor

          Use 2 x LC1D32U7 with a LAD9R1V reversing wiring kit

          What is the part number of the mechanical link for reversing contactors LC1D25U7

          LAD9R1V

          Advantys Configuration software version 7.0 and configuration of the ATV32 using the Canbus Extension Module

          Goals and Symptoms

          To configure the ATV32 as a CANopen device when using the Advantys STB CANopen extension module.

          Facts and Changes

          Advantys Configuration software version 7.0

          Causes and Fixes

          There is a patch that has to be loaded to add the ATV32 to the catalog to be able to configure the module as a device on the CANopen extension module network. Below is the patch and update User Manual.

          Attachments

          (Removed File URL: 212523_DF0A/patch_advantys_v7_0_0_3.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/640e1373e24c387bc1257bc300118c60/fl_block_5/0.EA?OpenElement&FieldElemFormat=gif)(Removed File URL: 212523_DF0A/STB_CANopen_std_devices_7_2013.zip)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/640e1373e24c387bc1257bc300118c60/fl_block_5/0.7A6?OpenElement&FieldElemFormat=gif)


          Legacy KB System (APS) Data: RESL212523 V1.0, Originally authored by DaSo on 09/18/2013, Last Edited by DaSo on 09/18/2013
          Related ranges: Modicon STB

          What is the part number of the mounting block to suit P2032/2VA, 10A, 240V 2 gang large format prestige plate?

          448 and 448SD are the mounting blocks to suit P2032/2VA, 10A, 240V 2 gang large format prestige plate.  Dimensions of the mounting block are as follows:

          For further information , please visit
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=448SD
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=448
          448SD
          User-added image
          448
          User-added image
           

          What is the mechanical interlock for an LC1D32U7

           The LAD9R1V reverser kit contains the mechanical interlock you need for the LC1D32U7

          What is the contactor to control 8A max with 24V AC coil and interlock kit to suite

           Part codes LC1D09B7 + LAD9R1V

          What is the interlock for LC1D38***

          As the interlock is not sold separate the part number needed is LAD9R1V

          What is the Mechanical Interlock for the LC1D12F7 ?

          LAD9R1V Is the code for the Mechanical and Electrical Interlock kit.

          What are the red safety covers for the TeSys D LC1D contactors?

          Issue:
          What is the  red safety covers for D line contactor.

          Product Line:
          D-Line IEC contactors 

          Environment:
          IEC Contactors  sold and used in the United States

          Cause:
          Requirement for safety covers in specific situations

          Resolution:
          LAD9ET1S for 9A to 65A contactors.
          LAD9ET3S for 80A to 95A contactors.
          LAD9ET4S for 110A to 150A contactors.
          There are also auxillary contacts available for front mount with a ref cover, model LADN22S, 2NO + 2NC

          Why will the Altivar ATV16 not run when set up for local mode?

          Issue: Why will the Altivar ATV16 not run when set up for local mode?
           
          Product Line: ATV16
           
          Environment: All
           
          Cause: Not running in local
           
          Resolution: Verify Fwd command and correct switch positions as well as verify reference frequency. Need to set LFr to the required setting.


           

          What is the replacement part number for an Altivar ATV16 keypad VW3A16102U?

          Issue: What is the replacement part number for an Altivar ATV16 keypad VW3A16102U?
           
          Product Line: ATV16
           
          Environment: All
           
          Cause: Keypad
           
          Resolution: There is no replacement keypad available for this since component is obsolete.


           

          170LNT71000 Devicenet Communication Adapter Exec Upgrade to v.1.41

          Release Notice

          The purpose of this Resolution is to inform 170LNT71000 Devicenet Communication Adapter users that the Exec has been upgraded to version 1.41.

          Goals and Symptoms

          Version 1.41 firmware resolves the following 170LNT71000 issues:

          • 1) When operating in 'Polled Mode' and mounted on discrete input bases only, 170LNT71000 Devicenet Comm Adapters would drop off the network every 10 seconds. The adapters would remain off the network for approximately 0.5 second then recover on its own.

            2) The input data from a bidirectional module will freeze at their last value if an output fault (ie. shorted output) occurs. The user would have to remove the fault to continue to read inputs correctly.

            3) If bi-directional modules are configured for polled & strobed modes, their outputs would remain in their last state if:
            • the communications cable is removed from the adapter,
            • the PLC is stopped, or
            • the fieldbus power is turned off.

          Causes and Fixes

          The 170LNT71000 firmware is NOT field upgradable.


          Legacy KB System (APS) Data: RESL192238 V1.0, Originally authored by DaDz on 07/02/2008, Last Edited by DaDz on 07/02/2008
          Related ranges: Modicon Momentum

          140NOE77110 Version 3.3 exec upgrade

          Goals and Symptoms

          Version 3.3 has incorporated 6 changes in the firmware to improve the operations of the NOE.

          Facts and Changes

          1.A new and improved Timeout and Retry Transmission algorithm has been added to the I/Oscanner client. If the connection to a device is disturbed, the retransmission requests are now sent
          to the device with adaptive timing and instead of with fixed timing.
          2. An error was corrected in the calculation of the Keep alive checksum.
          3. Change server retransmission retry time from 1.2 seconds to .5msec
          4 . Priority of the IPconfig task was increased from 100 to 35. This allows the gateway to be configured before the NOE can accept requests from other devices.
          5. The I/O scanner now support routers. This allows I/O scanning over different network domains that are linked by a network router (maximum TTL of 10).
          6. Changed Modbus server to implement a fast retransmission algorithm This upgrade can be downloaded directly to v3.0 units. Modules with lower versions must be upgraded to V3.0 before going to V3.3

          Causes and Fixes

          This upgrade can be downloaded directly to v3.0 units. Modules with lower versions must be upgraded to V3.0 before going to V3.3

          Attachments

          (Removed File URL: 164679_5E26/NOE77110.bin)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/7b12d118f892984385256f080062a406/fl_block_5/0.139E?OpenElement&FieldElemFormat=gif)


          Legacy KB System (APS) Data: RESL164679 V1.0, Originally authored by on , Last Edited by on
          Related ranges: Modicon Quantum

          What is the maximum distance the Altivar ATV16 keypad can be remotely mounted.

          Issue: What is the maximum distance the Altivar ATV16 keypad can be remotely mounted.
           
          Product Line: ATV16
           
          Environment: All
           
          Cause: N/A
           
          Resolution: We provide a 3 meter ( aproximately 10 feet ) cable which is the maximum available. The quality of the cable determines how much longer the cable can be but we do not support it.


           

          What is the replacement AC coil for CAD32 and CAD50 relay?

          Issue:
          AC coil replacement for CAD32 and CAD50

          Product Line:
          Relays

          Environment:
          Tesys CAD Control Relays

          Cause:
          Product selection

          Resolution:
          Volt = coil part number
          12 = LXD1J7
          21 = LXD1Z7
          24 = LXD1B7
          32 = LXD1C7
          36 = LXD1CC7
          42 = LXD1D7
          48 = LXD1E7
          60 = LXD1EE7
          100 = LXD1K7
          110 = LXD1F7
          115 = LXD1FE7
          120 = LXD1G7
          127 = LXD1FC7
          200 = LXD1L7
          208 = LXD1LL7
          220/230 = LXD1M7
          230 595 21 LXD1P7
          230/240 = LXD1U7
          277 781 30 LXD1W7
          380/400 = LXD1Q7
          400 = LXD1V7
          415 = LXD1N7
          440 = LXD1R7
          480 = LXD1T7
          600 = LXD1X7
          690 = LXD1Y7

           

          Is there a mechanical interlock for the LC1DT range of contactors?

          No, there is no interlock available specifically for the LC1DT contactors.

          The mechanical interlock that comes with the 3 pole reversing kit LAD9R1V will fit, although the power interlock and reverse wiring included in this kit will not be compatible.

          GV2 Adapter Plate Mounting

          Two lock elements come with LAD311. The first one, already mounted on LAD311 when delivered is suitable for almost all cases of LC1D contactor. However, depending on the type of coil of the contactor (DC or AC), this element shall be mounted in one position for DC or turned by 180° around an horizontal axis for AC coil contactor. Note that on the lateral face of this elements the markings “DC” or “AC” mounted upwards indicates the right position to be used. The second LAD311 lock element shall be used when mounting contactors LC1D09 to LC1D18 with screw clamp. In this case, this element shall be mounted on LAD311 instead of the first one which can be scrapped away.

          See attached document for reference. 

          How to set Analog Output in I/O expansion board to use 4-20 mA instead of 0-20mA?

          Issue
          User is trying to use 4-20mA scale for Analog Output instead of the default 0-20mA

          Product Line
          I/O expansion board

          Environment
          Analog Output Module
          ION modules

          Resolution
          You only need to calculate the Zero Scale and Full Scale values if your meter’s analog output port has a different range than the sensor connected to it; for example if your meter has a 0 - 20 mA range and the sensor reading the analog output port expects values in the 4 - 20 mA range. You can calculate the Full Scale and Zero Scale values by analyzing the system. The relationship between the Source input and the Normalized output is linear, so a graph can represent the six points used to produce the operation:


          The mathematical relationship between the values is shown by the following equation:


          Solving for Zero Scale:


          Calculation Example
          The meter is monitoring a 0 to 120 kW system. The receiving device can read a signal from 4 - 20 mA and your meter’s analog hardware output port has a 0 to 20 mA range. The Full Scale and Zero Scale registers need to be set up to scale the output accordingly. The variables for the module operation are:

           Full Scale = 120 kW
           X = 0 kW
           Af = 20 mA
           Ax = 0 mA
           Aa = 4 mA

          Solve for Zero Scale:


          The Analog Output module setup registers are programmed as follows:
           Full Scale = 120 kW
           Zero Scale = -30 kW
          This will produce a 0 to 120 kW output represented by a 4 to 20 mA signal.

          Those values can be programmed using ION Setup software. The software can be downloaded from here
          Refer to ION Setup user guide for information on how to connect to your meter in ION Setup software.

          After connecting to your meter in ION Setup, open setup assistant and navigate to Analog Out and choose which output you want to configure.
          You can configure the Source, Zero Scale, Full Scale, and port to use for that Analog Output as below:


           

          ETSNZ - Can Tesys F range contactors be used in safety applications?

          According to IEC60947-4-1 appendix F, mirror contact is one of the means necessary to ensure safety for contactors
          (in the standard "...mirror contact should not be relied upon exclusively as a means to ensure safety..." ).

          TeSys F contactors do not include internal mirror contacts. So we, Schneider, do not actively promote TeSys F as a contactor for safety applications.
          However, TeSys F can be fitted with auxiliary contacts add-on blocks. For some of these blocks LADN01, LADN02, LADN04, LADN11, LADN22, LADN31 and LADN13, a NC auxiliary contact has been recognised by VDE as mirror contact. This allows to use TeSys F in safety applications.
          Attached are the VDE Certificates recognising the NC auxiliary contact with the blocks mentioned above as mirror contact.

          To sum up and give clear answers to TeSys F and safety applications ;
          1. If Tesys F contactor can be used for safety applications?

          Yes, it can be used if, this is mandatory, it is fitted with one the above mentioned add-on blocks. VDE Certificate recognising the auxiliary contact as mirror can be provided.


          2. When asked, can we answer that Tesys F have mirror contact, provided by auxiliary contact blocks?

          Yes for the above mentioned add-on blocks and with the VDE Certificate

          What mechanical and electrical interlock kits are available to field assemble a reversing contactor from the LC1D09 through LC1D38 (9 to 38 amp ) Tesys contactors?

          Issue:
          Identifying interlocks to field assemble a reversing contactor

          Product Line:
          IEC contactors and starters

          Environment:
          Products sold and used in the United States

          Cause:
          Field assembling a reversing IEC contactor

          Resolution:
          Use the LAD9R1V kit for mechanical and electrical interlocking or use the LAD9R1 kit for mechanical interlocking without electrical interlocking. Both include power connections


           

          What interlock works with the LC1D128, 4 pole contactors?

          Issue:
          Interlocking 4 pole Tesys D contactors

          Product line:
          Tesys D IEC contactors

          Environment:
          4 pole contactors with 2NO and 2NC power poles - LC1D098 LC1D128 LC1D188 LC1D258

          Cause:
          Catalog lists interlock for contactors with 4NO poles only

          Resolution:
          It is recommended to use the LAD9R1V interlock kit with the contactors that have 2NO and 2NC power poles.  This kit provides the mechanical and electrical interlock needed to use in a reversing installation.
           

          Will the Compact NSX breaker be for sale in the USA or Canada?

          Issue:
          Where can I buy a Compact NSX breaker?

          Product Line:
          Circuit Breakers

          Cause:
          This breaker is popular overseas and there is interest in the US

          Resolution:
          There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

          If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

          For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
          https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page