D40A-D65A Rc 24-48V Ac Suppressor

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

suppressor module

Product compatibility

  • 3P LC1D40A...D80A
  • 4P LC1DT60A...DT80A
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Mounting mode

      by clips

      Net weight

      0.02 kg

      Ambient air temperature for operation

      -25-55 °C

      Ambient air temperature for storage

      -40-80 °C

      REACh free of SVHC

      Yes

      EU RoHS Directive

      Compliant

      Toxic heavy metal free

      Yes

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

       Pro-active China RoHS declaration (out of China RoHS legal scope)

      Environmental Disclosure

      ENVPEP111253EN

      Others

      Device short name

      LAD4

      Mounting location

      front

      Suppressor technology

      RC circuit

      [Uc] control circuit voltage

      24...48 V AC 50/60 Hz

      Maximum peak voltage

      3 Uc

      Compatibility code

      LAD4

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      17 g

      Package 1 Height

      3 cm

      Package 1 width

      4 cm

      Package 1 Length

      6 cm

      Unit Type of Package 2

      BB1

      Number of Units in Package 2

      10

      Package 2 Weight

      193 g

      Package 2 Height

      6.2 cm

      Package 2 width

      7.5 cm

      Package 2 Length

      12 cm

      Unit Type of Package 3

      S01

      Number of Units in Package 3

      100

      Package 3 Weight

      2.134 kg

      Package 3 Height

      15 cm

      Package 3 width

      15 cm

      Package 3 Length

      40 cm

      WEEE

      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      Show all specifications

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Product Environmental

      • Installation Instruction

      • Declaration of Conformity

      Frequently Asked Questions

      hide show

      What suppressor do I need for a LC1DT40 contactor 110Vac

      You need to use a LAD4RCU - RC circuit suppressor 110-240Vac.

      Will a LAD4RCE or LA4DRCU also fit a LC2D09 thru LC2D38 reversing contactors?

      Issue:
      Identifying accessories for reversing contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Accessories used on non-reversing contactors are also needed for reversing application

      Resolution:
      Yes, the LC2D contactors are provided standard with one on the left contactor. One may be added to the right contactor.


      CTA-ID : 2022733

      What is the replacement AC coil for CAD32 and CAD50 relay?

      Issue:
      AC coil replacement for CAD32 and CAD50

      Product Line:
      Relays

      Environment:
      Tesys CAD Control Relays

      Cause:
      Product selection

      Resolution:
      Volt = coil part number
      12 = LXD1J7
      21 = LXD1Z7
      24 = LXD1B7
      32 = LXD1C7
      36 = LXD1CC7
      42 = LXD1D7
      48 = LXD1E7
      60 = LXD1EE7
      100 = LXD1K7
      110 = LXD1F7
      115 = LXD1FE7
      120 = LXD1G7
      127 = LXD1FC7
      200 = LXD1L7
      208 = LXD1LL7
      220/230 = LXD1M7
      230 595 21 LXD1P7
      230/240 = LXD1U7
      277 781 30 LXD1W7
      380/400 = LXD1Q7
      400 = LXD1V7
      415 = LXD1N7
      440 = LXD1R7
      480 = LXD1T7
      600 = LXD1X7
      690 = LXD1Y7

       

      Are the LAD4 RC suppressors CE marked?

      Product Line:  
      Tesys D line Contactors and Accessories

      Resolution:
      Yes these are CE marked.
       

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 What is the maximum kW range that TeSys SoLink can be used with motor starter combination?

      TeSys SoLink is the connection module to connect GV2/GV3 motor circuit breakers to associated contactors and can be used with GV2 / GV3 breakers up to 30kW.
      For more information please visit the Link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink What is the maximum number of motor starters that can be connected and controlled with each logic controller?

      Each TM3 I/O module is able to monitor and control up to 4 motor starters and up to 56 motor starters can be connected to logic controller.
      For more information aboput this range please Visit the Schneider website on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      In regards to LAD5C11 LAD5C31 LAD5C12 LAD5C32 SoLink , Can TeSys SoLink be used with AC control supply?

      TeSys SoLink is suitable for 24VDC control supply; the TM3 I/O module provides the 24V DC control voltage to the motor starter.
      For more information on this range please visit the Schneider electric web site on the link provided
      https://www.schneider-electric.com.au/australia/en/products-services/offer-updates/news-viewer.page?c_filepath=/templatedata/Content/News/data/en/local/automation_control/general_information/2014/10/20141024_tesys_solink_integration_system.xml

      Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

      No, correct kit is a LAD9R3.

      Is it possible to mount a surge suppressor with LED (LAD4RCE) on the CA4KN**, low consumption DC control relay.

      CA4KN** control contactor comes fitted with integrated surge suppressor (bidirectional diode), thus there is no need for an external surge suppressor.
       
      However if the additional surge suppressor on the CA4KN22** is required, then it is possible to mount the suppressor (LAD4RCE).
       
      If the additional surge suppressor with LED is being used just for indication to verify that power is applied to the contactor, it is advisable to use a normal LED as per the coil voltage, connected to the coil supply (A1- A2).
       
      This will give the indication functionality as that of the additional external surge suppressor with LED, if that is what the only requirement is.

      What do the LA4D timing modules require for mounting on LC1D40A through LC1D65A contactors?

      Product Line:
       
      Tesys D line Contactors and Accessories

      Resolution:
       
      Mounting this module to TeSys LC1D40A through LC1D65A contactor requires the use of the LAD4BB3 wiring adaptor. This adaptor can be fitted only to contactors with no coil suppressor.
       

      What is the part number for a diode for a CA3KN relay?

      Issue:
      What is  the part number for a diode for a CA3KN relay?

      Product Line:
      Tesys Relays

      Environment:
      All Products

      Cause:
      Product selection

      Resolution:
      LA4KC1B or LA4KC1E is the diode and zener diode for the CA3KN relay.


      CTA-ID : 2015604

      Does LC1D80BD have internal bi-directional diode?

      Issue:
      LC1D80 and LC1D95 bi-directional diode

      Product Line:
      TeSys™ D Contactors

      Environment:
      Contactor Accessories

      Resolution:
      LC1D80 and LC1D95 does not have an internal bi-directional peak limiting diode on their DC coils. LA4DC3U (Screw connection of wire to the contactor coil terminals 24–250 Vdc, 3p-4p) must be ordered separately.

      The LC1D09 to LC1D38 have an internal diode by default on their DC coils.