Specifications

hide show
Range of product
TeSys D
Range
  • TeSys
  • Linergy
    • Device short name
      LA9D
      Product or component type
      set of connections
      Poles description
      4P
      Electrical circuit type
      changeover contactor
      Range compatibility
      TeSys D
      Product compatibility
      LC1D115004
      Net weight
      1.1 kg
      Compatibility code
      LA9D
      Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      1.078 kg
      Package 1 Height
      8.7 cm
      Package 1 width
      9.3 cm
      Package 1 Length
      34.8 cm
      Unit Type of Package 2
      S03
      Number of Units in Package 2
      9
      Package 2 Weight
      10.721 kg
      Package 2 Height
      30 cm
      Package 2 width
      30 cm
      Package 2 Length
      40 cm
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      WEEE
      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
      Warranty
      18 months

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Installation Instruction

      Frequently Asked Questions

      hide show

      What is the part code for terminal shrouds to fit LC1D115 or LC1D150

      The part code is LA9D115703 for 3 pole
      The part code for 4 pole is LA9D115704

      What is the difference between LA9D11569 and LA9D115691?

      Issue:
      Identifying differences between two part numbers

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Selecting between two similar part numbers

      Resolution:
      LA9D11569 is a set of power connections. LA9D115691 is the bottom connector only as shown on page 16-9 of Digest 173 for the LC1D115 and LC1D150 contactor.


       

      What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

      Issue:
      Identifying maximum voltage of an LC1D contactor

      Product Line:
      TeSys D Contactors

      Environment:
      IEC contactors and starters used in North America

      Cause:
      n/a

      Resolution:
      IThe maximum voltage per UL and CSA is 600VAC. 
       

      What code is a mechanical interlock for the 4pole LC1D1150046 contactor?

      LA9D11502 will fit the 4p LC1D115 and LC1D150 contactors

      Are replacement contacts available for LC1D115?

      Issue:
      Replacement contacts needed for 115 amp D line contactor

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying part number to order replacement contact kit

      Resolution:
      Yes, order LA5D1158031 for 3 pole kit or LA5D115804 for 4 pole kit.


      CTA-ID : 11125

      What is the replacement part for a 26896 RCB?

      The replacement part is a A9D61820.
      A9D11220 is best solution
      A9D11820 is an alternative 1 pole wide but no Neutral switching
      A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
       

      What is the alternative to the 4RCBE210/30?

      Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

      What is the part number for an A9D11810 but in "D" curve?

      need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
      for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
      and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
      User-added image    User-added image

      Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

      Issue:
      Can new accessories be used on older style contactors

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Identifying product compatibility

      Resolution:
      Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


       

      What is the difference between LC1D115 and LC1D1156?

      The 6 in LC1D1156.. is that the 6 denotes lug bar terminals. Use LC1D115.. for cable connections.


       

      What is the mechanical interlock for the LC1D115 contactor?

      Issue:
      Interlock needed for a pair of LC1D115 contactors

      Product Line:
      NEMA combination starters

      Environment:
      Products sold and used in the United States

      Cause:
      Application requires mechanical interlocking

      Resolution:
      LA9D11502. It includes the electrical interlocks.

       

      Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

      Issue:
      Auxiliary contact modules for the LC1D and LC2D contactors

      Product Line: 
      Contactor and Starters - IEC

      Environment:
      North American Products

      Resolution:
      Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
      Front Mounting; maximum of 1 block per contactor:

      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
      --1-----------1---------LADN11-----------LA1DN11
      --1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
      --1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
      --2-----------0---------LADN20-----------LA1DN20
      --2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
      --2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
      --0-----------2---------LADN02-----------LA1DN02
      --2-----------2---------LADN22-----------LA1DN22
      --2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
      --2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
      --2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
      --3-----------1---------LADN31------------LA1DN31
      --3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
      --1-----------3---------LADN13------------LA1DN13
      --4-----------0---------LADN40------------LA1DN40
      --4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
      --0-----------4---------LADN04------------LA1DN04




      Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
      --1-----------0--------LADN10----------LA1DN10
      --0-----------1--------LADN01----------LA1DN01

      Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
      (*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

      N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
      --1-----------1--------LAD8N11----------LA8DN11
      --2-----------0--------LAD8N20----------LA8DN20
      --0-----------2--------LAD8N02----------N/A

      Footnotes:
      {1} EN50 012 Machine Tool Terminal Markings
      {2} (2) NO Sealed Dust Tight Contacts
      {3} Gold Flash Contacts
      {4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
      {5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
      {6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
      Show More