LC Metal 9P Surface Mtd

Catalogue Number: L9S
LC METAL 9P SURFACE MTD
L9S
LC METAL 9P SURFACE MTD
L9S
Retail
$308.89
RRP (Inc. GST)

Specifications

hide show
Range
Acti 9
Product or component type
Load Centre
Device application
distribution
Provided equipment
  • DIN rail
  • enclosure
    • Number of poles
      9
      Material
      steel
      Number of horizontal rows
      1
      Number of 18 mm modules per row
      9
      Type of rail
      DIN
      Mounting plate description
      without mounting plate
      Height
      231 mm
      Width
      293 mm
      Depth
      66 mm
      Enclosure mounting
      surface
      IP degree of protection
      IP40
      Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      2.411 kg
      Package 1 Height
      8.7 cm
      Package 1 width
      24 cm
      Package 1 Length
      36.5 cm
      EU RoHS Directive
      Not applicable, out of EU RoHS legal scope

      Documents & downloads

      hide show
      Filter items
      • All

      • Technical Data Catalogues

      • Specifications

      Frequently Asked Questions

      hide show

      What is the ampere rating on the L9S type of load centers?

      Ampere rating will 100 amp for the bus bar.
       

      What is the code for the tool to extract BA9s lamps?

      The code for this is XBFX13

      What are the part numbers for Padlocking device which will go on LHS and RHS of Acti 9 iC60 and RCBO's?

      Part number A9A26380 is for mounting on the left side of Circuit Breaker.
      Part number A9A26381 is for mounting on the  Right side of Circuit breaker.
      For further details please follow the below link,
      https://www.tracepartsonline.net/(S(jj1xcpflpzf1tyxwjtna0vip))/partdetails.aspx?PartID=10-02112015-105620&class=SCHNEIDER_ELECTRIC_DISTRI&clsid=/SCHNEIDER_DISTRI/F_SCHNEIDER_DISTRI/SCHNEIDER_DISTRI.030/SCHNEIDER_DISTRI.030.010/
      Image result for A9A26380 schneider

      What is the TSX ESY 007 module?

      The TSX ESY 007 module will allow you to keep the TSX7 Racks and I/O modules and upgrade you system to UNITY V2.1 or later.
      The TSX ESY 007 Module acts as gateway for retrieval of I/O of TSX Series 7 PLC racks to a Premium PLC, via the I/O extension bus (TSX LES 20, TSX LES 200 or TSX LFS 200 modules). It is intended for upgrading automated systems equipped with programmable TSX Series 7 Plc's 40 (47, 67, 87 and 107 in version V2, V3, V4 or V5).

      It is mounted in a Premium rack equipped with a Premium UNITY V2.10 minimum processor. The configuration of this coupler in UNITY Pro is protected by access rights. These rights may only be used by Schneider Services Industries entities in France, and abroad by Schneider Services entities or otherwise by its representatives.
      Recovery of the PL7-3 program of the system to be upgraded is possible through the successive use of PL7-3/PL7 Pro and PL7 Pro/UNITY Pro converters.

      General Presentation of TSX ESY007 Module.zip


      Legacy KB System (APS) Data: RESL172643 V1.0, Originally authored by on , Last Edited by on
      Related ranges: TSX serie 7

      What is the weight of a ATV61HD55N4 ?

      Issue: 
      What is the weight of a ATV61HD55N4 ?

      Product Line:
      ALTIVAR 61 

      Environment:
      Frame Size 8 : ATV61HD45N4, ATV61HD55N4, ATV61HD75N4, ATV61HD37Y to ATV61HD90Y
       
      Cause:
      Installation / Setup

      Resolution:
      Weight   99.21 lbs /  45kg

      What is the difference between 29S and 36S volts mode in ION8650?

      Issue
      ION8650 socket meters have a volts mode for 29S and 39S.  When looking at the wiring diagrams in the installation guide they look identical.

      Product Line
      ION8650 

      Environment
      ION8650 socket meters

      Resolution
      On socket meters, the volts mode modifies the reference spades for each measured quantity.
      IE which quantity, V1, V2, V3, I1, etc... is connected to which input terminal of the meter.

      The picture below shows the difference between each socket and the corresponding volts mode. This is all dependant upon physical connection and the base socket installed.
      Please note the information in the picture notes that a 9S base can function as any of these 3 volt modes depending upon your physical connections to the base.


       

      Sur les ATV28,on peux communiquer par Profibus avec les modules VW3A66307. sur ces modules,on peux raccorder 4 ATV.Peux t'on a l'aide de 8 modules rac...

      Goals and Symptoms

      Sur les ATV28,on peux communiquer par Profibus avec les modules VW3A66307. sur ces modules,on peux raccorder 4 ATV.Peux t'on à l'aide de 8 modules raccorder 30 ATV28.

      Facts and Changes

      ATV28 profibus.

      Causes and Fixes

      Pas de problèmes ( 4 x 8 = 32 ) et en dessous de la limite profibus.


      Legacy KB System (APS) Data: RESL156422 V3.0, Originally authored by on , Last Edited by on
      Related ranges: Altivar 28

      Quelles sont les versions du logiciel PC compatibles avec l'ATV66xxx S247 ( levage) .

      Goals and Symptoms

      Quelles sont les versions du logiciel PC compatibles avec l'ATV66xxx S247 ( levage) .

      Facts and Changes

      ATV66xxx S247

      Causes and Fixes

      Il est possible d'utiliser la version 3.1 ou 3.2 du logiciel PC mais les paramètres spécifiques tels que gain couple , courant de levée de frein ne seront pas accessible, les reprendre à la main.

      Is it possible to install the Fusarc fuse in the upstream of LBS (Load Break Switch).

      Yes, it is possible to install the Fusarc fuses in the upstream of Load Break Switch (LBS) switch.

       
      Note:
       
      1. Refer the attached sheet to choose and install the right fuse.
       
      2. The current rating for the Fusarc Fuses has also been provided in the attached document.

      What are the Dynamic Load ratings and Shipping Load ratings for NetShelter CX cabinets?

      Issue:
      A customer needs to know how much weight they can load into their NetShelter CX for static installation, dynamic installation (rolling on flat surface) or to ship loaded with equipment. 

      Product Line:
      NetShelter CX

      Environment: 
      All versions and serial ranges.

      Cause:
      A customer wants to load the cabinet and move it, or ship it. 

      Resolution: 

      Static Load Weight Rating is the maximum weight of the cabinet, plus installed equipment (with the feet locked), in it's final location. 

      Dynamic Load is often confused with Shipping Load. These two ratings are different and care should be taken to distinguish between them.

      Dynamic Load Weight Rating is the maximum rolling load of the cabinet. This is the maximum allowable weight of equipment installed in the cabinet during movement from one location to another within the same data center. This assumes level flooring on a smooth surface. Carpet is not a smooth surface.
      In conjunction with the cabinet rating, the applicable ratings of any raised floor or other flooring installed in the data center should not be exceeded.
      Example: a customer who wishes to move a cabinet from one row to another in a data center must remove equipment until the weight is equal to (or below) the Dynamic Load Rating before being moved.  

      Shipping Load Weight Rating is the maximum allowable weight of equipment installed in the cabinet during any shipping process where the cabinet is to be moved outside the data center. Shipping cabinets with equipment installed requires the use of a special cabinet with heavy duty shock packaging. Shock packaging is required to ship a cabinet with installed equipment. Shock packaging contains a cushioned pallet designed to absorb some of the impact forces experienced during the shipping process (truck or rail vibration and impact). This packaging has undergone rigorous testing to ensure safe transport. 

       
      MODEL STATIC LOAD RATING DYNAMIC LOAD RATING SHIPPING LOAD RATING
             
      AR4000MV 704 lbs (320 kg)  458.5 lbs (208 kg) na
             
      AR4018A (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  na
      AR4018IA (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  na
      AR4018SP (X429, X431, X432)  1826 lbs  (830 kg)  970 lbs (441 kg)  700 lbs (319 kg) 
             
      AR4024A (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  na
      AR4024IA (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  na
      AR4024SP (X429, X431, X432)  1771 lbs  (805 kg) 928 lbs (422 kg)  800 lbs (363 kg) 
             
      AR4038A (X429, X431, X432)  1716 lbs (780 kg)  845 lbs (384 kg)  na
      AR4038IA (X429, X431, X432)  1716 lbs (780 kg)  845 lbs (384 kg)  na

      Support on Buildings Management Systems and Pelco Security Solutions

       For support on Buildings Management Systems and Pelco Security Solutions please visit:  https://buildingskb.schneider-electric.com/

      Video: Programming an 8 Channel Relay Panel Time Clock Controller

      Issue:
      How to wire and program the Schneider Electric Relay Panel.

      Product Line:
      Lighting Relay Panel

      Environment:
      Commercial Building, Lighting Control

      Cause:
      Training Information

      Resolution;
      Training video below shows basic programming of the SERPTC411 controller.  The times within the video where certain topics are covered are listed below.

      0:00   Introduction
      1:10   LCD Screen Explanation, Manual Operation of a Relay
      2:35   Program a Time Based ON Event
      6:47   Program a Time Based OFF Event
      8:12   Set the Time of Day, Latitude and Longitude
      10:23  Clear Memory

      Show More