hide show
  • C-Bus current requirement 18 mA, powered from C-Bus network, does not provide power for the C-Bus network
  • Maximum units per network 100
  • Network clock software selectable
  • Network burden Software selectable when Unit Address is 001
  • AC input impedance 100 kOhm at 1 k Hz
  • Warm-up time 10 s
  • Electrical isolation 3.75 kV from C-Bus to mains
  • Input voltage for fan motor 100 V AC to 240 V AC; input circuit must have a suitable circuit breaker
  • Fan load rating 1.5 A
  • Switch duty type (S1) Continuous duty. Line and neutral are switched. Fan motor and neutral are switched
  • Speed control Capacitive; capacitor block supplied by fan manufacturer for Low and Medium speeds. High speed uses direct on-line (no capacitor in the circuit). Three unique fan speeds Low, Med and Hi and Off
  • Connectors C-Bus: 2 x RJ-45
  • Capacitor block: 3 x push button for one 1.5 mm²
  • Fan: 2 x screw type for one 1.5 mm² wire
  • Input Power: 2 x screw type for up to two 1.5 mm² Indicators Unit, C-Bus, 3 x Fan speed
  • Control Local override pushbutton, not illuminated
  • Class of switch Class II
  • Rated impulse withstand voltage 4 kV
  • Proof tracking index (PTI) 175
  • Pollution degree 2
  • Glow wire test (GWIT) Level 3, 850° C
  • Mounting type DIN rail, or wall or ceiling space mounting in the optional plastic enclosure; For indoor use only
  • Operating temperature 0° to 65° C
  • Humidity 10 to 95% RH, non condensing
Range of product
C-Bus
Range
C-Bus
Product brand
Clipsal
Product or component type
relay
Device application
fan speed controller
Load type
inductive
Rated voltage
100-250 V AC 50/60 Hz
[Us] rated supply voltage
15...36 V DC
Nominal output power
350 W
Number of channels
1
Number of modules
3
Local signalling
LED
Connector type
screw terminals
Device mounting
DIN rail
Width
210 mm
Height
75.5 mm
Depth
66 mm
IP degree of protection
IP20
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Product Environmental

  • End of Life Manual

  • Operating Manuals

  • System User Guide

  • Specifications

  • Application Solutions

  • Certificates (MSDS)

  • Corporate Marketing

  • Software - Released

Frequently Asked Questions

hide show

How do I determine if a fan is suitable to be used with the C-Bus fan relay unit

Any fan which is switched via a 3 wire capacitor (low, medium, common) will be acceptable

Can you have more than one fan controlled from a DLT?

You cannot natively control more than one fan. However implemention of multiple fans can be achieved through the use of logic, please contact Technical Support for a logic example.

Any logic examples are provided as is and are not able to be supported.

What is required for a Fan to be compatible with C-Bus?

For a fan to be compatible with C-Bus, it will require a 3 wire capacitor built for low and medium speeds.

This capacitor can then be wired into a L5501RFCP which will act on behalf of the rotary dial.

From there, a C-Bus switch can then be programmed to step through the speeds.

What is the power output limitations of the L5501RFCP C-bus Sweep fan control?

The fan load rating must not exceed 1.5Amps.
The L5501RFCP C-Bus Ceiling Sweep Fan Controller unit is a DIN rail mounted C-Bus output device that provides speed control for a ceiling sweep fan. The Fan Controller uses multiple relays and a dual capacitor block for speed selection.
Some of its key features are:
  • C-Bus current requirement 18 mA, powered from C-Bus network, does not provide power for the C-Bus network
  • Maximum units per network 100
  • Network clock software selectable
  • Network burden Software selectable when Unit Address is 001
  • AC input impedance 100 kOhm at 1 k Hz
  • Warm-up time 10 s
  • Electrical isolation 3.75 kV from C-Bus to mains
  • Input voltage for fan motor 100 V AC to 240 V AC; input circuit must have a suitable circuit breaker
  • Fan load rating 1.5 A
  • Switch duty type (S1) Continuous duty. Line and neutral are switched. Fan motor and neutral are switched
  • Speed control Capacitive; capacitor block supplied by fan manufacturer for Low and Medium speeds. High speed uses direct on-line (no capacitor in the circuit). Three unique fan speeds Low, Med and Hi and Off
  • Connectors C-Bus: 2 x RJ-45
  • Capacitor block: 3 x push button for one 1.5 mm²
  • Fan: 2 x screw type for one 1.5 mm² wire
  • Input Power: 2 x screw type for up to two 1.5 mm² Indicators Unit, C-Bus, 3 x Fan speed
  • Control Local override pushbutton, not illuminated
  • Class of switch Class II
  • Rated impulse withstand voltage 4 kV
  • Proof tracking index (PTI) 175
  • Pollution degree 2
  • Glow wire test (GWIT) Level 3, 850° C
  • Mounting type DIN rail, or wall or ceiling space mounting in the optional plastic enclosure; For indoor use only
  • Operating temperature 0° to 65° C
  • Humidity 10 to 95% RH, non condensing