C-Bus Dimmer Module, 2 Channel, Leading Edge, 250V, 10A

C-Bus Dimmer Module, 2 Channel, Leading Edge, 250V, 10A

C-Bus Dimmer Module, 2 Channel, Leading Edge, 250V, 10A

Item Number: L5102D10

Retail
N/A
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

C-Bus

Product brand

Clipsal

Product or component type

dimmer

Device application

control

Physical

Device presentation

basic element

Load type

inductive

[Ue] rated operational voltage

220...240 V AC

Local signalling

LED

Number of channels

2

Mounting support

wall

IP degree of protection

IP20

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Power consumption in VA

2400-2400 VA

Network frequency

47...63 Hz

Nominal output power

2300 W

Size

base: 240 x 202 x 75 mm

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

4.4 kg

Package 1 Height

8 cm

Package 1 width

23.4 cm

Package 1 Length

24.5 cm
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Specifications

  • Application Solutions

  • Corporate Marketing

Frequently Asked Questions

hide show

Is the L5103D5LP available in New Zealand

No use a L5103D10LP

Does the L5508D1A come with a C-Bus power supply?

Yes L5508D1A is supplied with a C-Bus power supply.
Please see link below for more information.

https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508D1A

what is the replacement for an LC1D2510 contactor with 240v coil ?

The replacement is an LC1D25U7

What is part no for 8 Channel Dimmer with power supply

Part no is L5508D1A

Will the LAD** time delay auxiliary contact module fit the D2 series pre-Tesys contactors?

Issue:
Can new accessories be used on older style contactors

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Identifying product compatibility

Resolution:
Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.


 

Are EasyPact CVS circuit breakers for sale in the USA or Canada?

Product Line:
EasyPact CVS circuit breakers

Cause:
This breaker is popular overseas and there is interest in the US

Resolution:
There are no plans for a general release of the EasyPact CVS circuit breaker line in North America.

Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

Issue:
Auxiliary contact modules for the LC1D and LC2D contactors

Product Line: 
Contactor and Starters - IEC

Environment:
North American Products

Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04




Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01

Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A

Footnotes:
{1} EN50 012 Machine Tool Terminal Markings
{2} (2) NO Sealed Dust Tight Contacts
{3} Gold Flash Contacts
{4} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

What to do when C-Bus dimmer channel will not turn off ?

First of all check that the programming is correct.
If using LED lights, the LED may stay on when the channel is off, this is due to the leakage current being enough to power the LED, use of a 31LCDA may resolve this issue.
If using Halogen and  the channel will not turn off, there may be damage to the electronics on this channel - Electricians only to perform this check, disconnect the Active's , Neutral and Earth from the unit, remove the cable for the load on that channel then with a multimeter check between the Neutral and that suspect channel output, if you see a low resistance the Triac has shorted.
Advise not to use this channel and label as faulty, other channels on this dimmer should still be ok to use as per normal, alternatively you could return this unit for a quote on repair, note a repair may not be possible.

What dimming technologies are supported by Clipsal C-Bus?

Issue:
What light fixture dimming technologies are supported by Clipsal C-Bus?

Product Line:
Clipsal C-Bus Automation

Environment:
Clipsal C-Bus
Commercial or Residential Installation
United States

Cause:
When specifying C-Bus to control dimming fixures, the Lighting System Designer/Engineer must specify the appropriate dimmers and light fixtures that are compatible with one another.

Resolution:

It is important to match the correct dimmer to the ballast and/or bulb in light dimming applications.  The different dimming technologies are not cross-compatible. 

Forward Phase Angle Dimming
Forward Phase Angle Dimming is the technolgy of C-Bus Pro Dimmer SLC5104RD5, SLC5102TD10 SLC5101TD20 and Phase Angle Dimmers SLC5504TD4A, SLC5504TD4AP, SLC5508TD2A, SLC5508TD2AP.  These types of dimmers are also known as Leading-Edge Dimmer, Standard Phase Dimmer, Triac Dimmer, and MLV Dimmer.   In Forward Phase angle dimming, the sine wave form is shut off for a portion of every half cycle (120 times per secont)  after the AC voltage crosses the zero voltage line.  Resistive loads such as incandescent and tungsten halogen lamps work with this technology.    Low voltage ballasts that use a magnetic transformer (MLV) to create the lamp voltage (6, 12, 24V) as well as neon (cold-cathode) ballast will work with a forward-phase angle dimmer as well.   Some types of fluorescent dimming ballast and LED power supplies may operate with forward phase angle dimmers but it is strongly advised to check with the manufacturers of the ballast and lamp.






Reverse Phase Angle Dimming
Reverse Phase Angle Dimming is also known as Trailing Edge Dimmer or ELV-Type Dimmer.   Like Forward Phase Angle technology, the sine wave is also cycled on/off every half cycle except that the voltage is energized after crossing zero.  This is opposite for Forward Dimming where the voltage is energized before crossing zero.   Reverse phae angle dimmers are often required on dimmable LED and 3-wire CFL fixtures using Electronic Low Voltage (ELV) solid state transformers.  Clipsal C-Bus in the United States does not support Reverse Phase Angle Dimming.




0-10 VDC 
Some Light Fixure Dimmer Drivers require an analog 0-10 VDC control signal from which the fixture will references as a control input to its light fxture dimming circuit.   Clipsal C-Bus devices SLCLE5504TAMP or SLCLE5504HAMP can be used to send 0-10 VDC signals to these types of light fixtures.
 

Why can't I purchase Schneider Electric US Lighting Control products any more?

Issue:
As of March 1, 2015 all US Lighting Control products (EXCEPT Powerlink and MVP panels) will enter their obsolescence phase and will no longer be purchasable for new orders. Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiative and concentrate our effort in new businesses with higher growth potential – Connected Home, Building Control in small buildings, and Electric Vehicle solutions.

Product Line:
All US Lighting Control product except Powerlink and MVP panels are affected. CBus, Occupancy Sensors, Low Voltage Switches, Relay Panels, Emergency Lighting Control Panels, Schneider Electric branded Current Limiting Panels, and Architectural Dimming Panels.

Environment:
US Lighting Control products

Cause:
Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiatives.

Resolution:
See cross reference sheet attached for available completive cross references.