4 hole neutral meter link - t type

Max 4 Neutral Active Meter Links, 4 Hole, T-Type

Catalogue Number: L4T35
4 hole neutral meter link - t type
Retail
$55.8*
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Product or component type
neutral link
REACh Regulation
Free of Substances of Very High Concern above the threshold
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

L1 VME Does the L4T35R come in any other sizes?

No. The L4T35R only comes as T type 25mm²

Is there a junction box in red similar to the 544

 Part code L4T35R

Whats the dimensions of a L4T35R

 The dimensions 65 x 46 x 43mm (L x W x D)

What are the Clipsal BPT2 Dimensions?

  • Dimensions: 58 x 40 x 40 mm
https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=BPT2

What would be a replacement mech for a WHT35 ?

The WHT35 has been replaced with the WHB340-RG however we don't do spare mechanisms for it.

Surface Switches - Weather Protected, Surface Switches - WHB Series - Weathershield - IP66, Switch 440V 40A - triple pole.

The WHA/WHB/WHC series of weatherprotected isolating switches is a robust range of switches suitable for virtually any external application. The impact resistant base and cover will survive the hardest knocks in almost any installation. The two sections are sealed with a co-injection gasket. The range provides ample conduit entries and is suitable for side entry from a vertical duct. Its compact size means it is aesthetically pleasing and suits installations where space is limited such as with residential air conditioning applications.

Please see following link under the documentations tab for complete whb range and technical data.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=WHB340

What is the Din rail terminal block to suit the LRD12?

The LAD7B106 fits the LRD01 to LRD35 range.
 

What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

Issue:
Identifying differences between two similar part numbers.

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Choosing the correct part number

Resolution:
LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

 

Can the LRD01 to LRD35 range be put back to manual from automatic.

This LRD range cannot be put back to Manual reset, once the overlaod has been changed from Manual (factory default) to Automatic.

What is the difference between LAD703 and LA7D03

Issue:
Identifying differences between two similar part numbers

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Identifying differences between two similar part numbers

Resolution:
Both will remotely stop (trip) or electrically reset the overload, however;
LAD703 is used on Tesys overload LRD01 through LRD35 and LR3D01 to LR3D35.
LA7D03 is used on all other LR*D overload relays other than LRD01 to LRD35 and LR3D01 to LR3D35.


 

Are EasyPact MVS circuit breakers for sale in the USA or Canada?

Issue:
Where can I buy a EasyPact MVS breaker?

Product Line:
EasyPact MVS circuit breakers

Resolution:
There are no plans for a general release of the EasyPact MVS circuit breaker line in the US.
 

What are the wiring terminals on the IEC LRD* overload relays?

Product Line:
Tesys D line Overload Relays
 
Resolution:
The normally closed overload contact are terminals 95 & 96; and the normally open overload contact are terminals 97 & 98.
T1 T2 and T3 are the load terminals. 

The normally closed control circuit contact will open when there is a fault, this contact is typically used in series with the control circuit. 

The normally open trip signal contact closes when a fault occurs which is typically used to control a pilot light, or alarm. 

 

Will the Compact NSX breaker be for sale in the USA or Canada?

Issue:
Where can I buy a Compact NSX breaker?

Product Line:
Circuit Breakers

Cause:
This breaker is popular overseas and there is interest in the US

Resolution:
There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

For support on these breakers, Please see the following link to Global Operations where you can select other Countries: