OptiLine 70 Trunking in aluminium 95x55. Stop end
Stop End for Alu Trunking 75x55 and 120x55
OptiLine 70 Trunking in aluminium 95x55. Stop end
Stop End for Alu Trunking 75x55 and 120x55

OptiLine 70 Stop End, PC/ABS, Aluminium MetAllic

Catalogue Number: ISM11354
OptiLine 70 Trunking in aluminium 95x55. Stop end
Stop End for Alu Trunking 75x55 and 120x55
OptiLine 70 Trunking in aluminium 95x55. Stop end
Stop End for Alu Trunking 75x55 and 120x55
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
OptiLine 70
Cabling installation system
trunking
Product or component type
stop end
Colour tint
aluminium metallic
Quantity per set
set of 2
Trunking material
aluminium
Trunking dimension
120 x 55 mm
Fixing mode
  • screw
  • snap-fitted
    • Material
      PC/ABS painted
      Length
      21 mm
      Height
      124 mm
      Width
      56 mm
      Standards
    • 73/23/EEC
    • 93/68/EEC
    • EN 50085-1:2005
    • EN 50085-1:2013/A1
    • EN 50085-2-1:2006
    • NF C 68-102
    • EN 50085-2-1:2011/A1
      • Ambient air temperature for operation
        -25-60 °C
        IP degree of protection
        IP40
        IK degree of protection
        IK07
        Sustainable offer status
        Green Premium product
        REACh free of SVHC
        Yes
        EU RoHS Directive
        Pro-active compliance (Product out of EU RoHS legal scope)
        Toxic heavy metal free
        Yes
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
         Pro-active China RoHS declaration (out of China RoHS legal scope)
        Environmental Disclosure
        ENVPEP060309EN
        Circularity Profile
        N/A
        Warranty
        18 months

        Documents & downloads

        hide show
        Filter items
        • All

        • Technical Data Catalogues

        • Technical Leaflet

        • Product Environmental

        • Operating Manuals

        • Declaration of Conformity

        Frequently Asked Questions

        hide show

        What is the part numbers for the Optiline 70 dual ducting and accessaries?

        What is the part code for the Joint cover kit for ISM11500

         The part code is ISM11506

        What is the code for the dividers to suit the ISM11100

        The part code is ISM10902

        What is the fill volume of the ISM11100 with data cable

        The fill volume is 27 cables

        What is the part number for a power/data shroud to suit ISM11550, Optiline 70 two compartment duct?

        MDEOLSPTD is the power/data shroud to suit ISM11550, Optiline 70 two compartment duct.
        For further information, please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=MDEOLSPTD

         

        What is the part number for the T-Piece for the Actassi trunking?

        T-Piece - ISM11107

        What is the code for the adaptor for sockets to mount in actassi trunking

        Code = ISM15150

        Is the ISM11100 trunking made from PVC?

        Yes, the ISM11100 trunking is made from PVC.

        Some of the key features are:
        • Easy installation – symmetrical design and click-in mounted accessories
        • Pre-punched slots in the partition walls of the PVC trunking – easy to make holes to feed cables between the compartments
        • Adaptors and boxes with several unique installation benefits
        • 55 mm deep – high capacity and safe wire connections
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=ISM11100P

        What part can be used to mount switch plates and sockets onto Trunking?

        The ISM15150 is the mounting clip to mount standard switch plates and sockets onto trunking.

        Why can't I order the ISM15015 and ISM15150 for Optiline 70 floor boxes?

        The  ISM15015 and ISM15150 for Optiline 70 floor boxes are not offered for sale in Australia. The part offered here is the MDEOLSPTD.

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=MDEOLSPTD
         

        Does IEM1350 meter display Current?

        Unfortunately the IEM1350 meter does not display Current on the Meter or via Modbus.

         

        Is the ISM14500 available to purchase?

        No, the Actassi 70 Trunking range is completely discontinued. This covers all "ISM" prefixed items EXCEPT the ISM15150 - which is an adapter clip, also used elsewhere for fixing standard plates.

        UL Listing iEM3000 series and PM3000 series meters

        Issue
        What is the UL listing for the iEM3xxx Energy meters and PM3xxx power meters
         
        Product Line
        iEM3100, iEM3110, iEM3115, iEM3135, iEM3150, iEM3155, iEM3165, iEM3175, iEM3200, iEM3210, iEM3215, iEM3235, iEM3250, iEM3255, iEM3265, iEM3275, iEM3300, iEM3310, iEM3335, iEM3350, iEM3355, iEM3365, iEM3375, iEM3455, iEM3465, iEM3555, iEM3565, iEM3455C1, iEM3455C2, PM3200, PM3210, PM3250, PM3255

        Resolution 
        The iEM3xxx and the PM32xx are listed as Measuring, Testing and Signal-generation Equipment which complies with UL standard 61010 " Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 2-201: Particular Requirements for Control Equipment" and UL50 "Enclosures for Electrical Equipment, Non-Environmental Considerations" . The UL listing is E360954

        Link to UL Listing

        Can the IEM3000 series read energy output from a Solar Panel?

        To be able to measure the energy out from a Solar Panel a meter needs to be able to do Four Quadrant Calculation.

        This means it is capable of Identification of imported and exported active and reactive energy allows you to monitor energy flow in both directions: delivered from the utility and produced on-site.

        In the iEM3000 series the following meters are capable of Four Quadrant Calculation.

        iEM31** range - iEM3135, iEM3155, iEM3165, and iEM3175
        iEM32** range - iEM3235, iEM3255, iEM3265, and iEM3275
        iEM33** range - iEM3335, iEM3355, iEM3365, and iEM3375
        iEM34** range - iEM3455, iEM3465, iEM3555, and iEM3565


         

        Where can I find the register list for the iEM3100, iEM3200, and iEM3300 series of meters?

        Issue
        A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
         
        Product Line
        iEM3100, iEM3200, iEM3300 series
         
        Environment
        iEM3100, iEM3200, iEM3300 series
         
        Cause
        A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
         
        Resolution
        The user manual for the iEM3100, iEM3200, and iEM3300 series of meters (document reference number DOCA0005EN-04) has a register list in Chapter 5: Communications via Modbus RS-485. See page 57 of the pdf document attached   (doca0005en-04.pdf)