OptiLine 50 Trunking, Wall frame 120 mm

OptiLine 50 Wall Frame, 140 x 63 mm, PC/ABS

Catalogue Number: INS12405
OptiLine 50 Trunking, Wall frame 120 mm
Retail
N/A
RRP (Inc. GST)

Specifications

hide show
Range of product
OptiLine 50
Product or component type
wall frame
Quantity per set
1 piece
Colour tint
white (RAL 9010)
Trunking dimension
140 x 63 mm
Trunking material
  • aluminium
  • plastic
    • Fixing mode
      screw-fixed
      Material
      PC/ABS
      Length
      113 mm
      Height
      190 mm
      Width
      225 mm
      Ambient air temperature for operation
      -25-60 °C
      IP degree of protection
      IP40
      IK degree of protection
      IK07
      Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      44 g
      Package 1 Height
      19 cm
      Package 1 width
      2.25 cm
      Package 1 Length
      11.3 cm
      Sustainable offer status
      Green Premium product
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP090918EN
      Warranty
      18 months

      Frequently Asked Questions

      hide show

      Can part number INS51245 be installed in concrete?

      No part number INS51245 can not be installed in concrete.

      What is the key lock replacement for a INS1250?

      You can replace the key lock with the following models

      33190 (https://www.schneider-electric.com/en/product/33190/ronis-keylock---for-masterpact-nt---off-position---2-same-key---el24135/)
      41950 (https://www.schneider-electric.com/en/product/41950/2-key-lock-%2B-1-flat-key).


       

      What is the part number for an end stop for the Optiline 50 ducting , INS12300?

      The part number for an end stop for the Optiline 50 ducting , INS12300 is - INS12304

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS12304
      User-added image

      Does the INS62045 come with or without the actual power/data outlets?

      They come empty by default.

      What is the code extended front rotary handle / shaft for an INS250?

      Code = 31050

      When running redundant 140CPS124 00 power supplies, is it possible to replace a failed 140CPS124 00 with the 140CPS124 20?

      No. Each power supply making up the redundant pair has to be of the same type. Mixing power supply models may result in unintended operation.







      R-20818

      What are the terminal spreaders that can be used for the INS320?

      LV432490 - 52.5mm Pitch
      Please follow the link for the data sheet:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432490
       

      What is the part number for a floor box which is 310 x 310?

      The INS62044 has the dimensions of  311mm x 311mm x 105mm complete with a square plastic recessed lid. This part has provisions for 4 power and 4 data (suits 4 x 2000 or C2000 Series outlets). 
      The base is metal which is used primarily in a concrete floor.

      For further information please visit the following link: www.clipsal.com/Trade/Products/ProductDetail?catno=INS62044
       

      What is the part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points?

      The part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points is - INS43406 & INS62024 & INS62027

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS43406
      https://www.clipsal.com/Trade/search-results?q=INS62024
      https://www.clipsal.com/Trade/search-results?q=INS62027
      User-added image

      How to configure MV-90 to resolve communications problems for devices that consistently have communications or time-out errors.

      Goals and Symptoms

      This article introduces 3 useful MV-90 configuration parameters which could help to solve communication problems for devices that consistently have communication errors or time-out errors.

      Causes and Fixes

      Steps to configure MV-90:
      1) Create a .cfg file with the following configuration parameters by using notepad.
      i) Record Buffering setting
      RECBUF=n
      The value of n is an integer number between 1 and 15, which represents the number of records that should be read with each communication with the meter. The TIM module will use this parameter at the beginning of the interrogation and will dynamically reduce the number of records read with each command if communication errors are encountered. For interrogations performed over a slow communication link, we recommend that n be set to 15. For devices that consistently have communications errors, a setting of 1 is recommended. Default Value = 15.

      ii) Severe Timeout setting
      TO=n
      The value of n represents the amount of time the TIM waits for a response from the meter in hundredths of a second. This setting should only be used if the TIM is failing interrogations with an I/O Timeout Error (return code 22). If this happens, attempt to use a bigger number that will allow the meter interrogations to complete consistently. Default Value = 300.

      iii) Intra-byte Timeout
      ITO=n
      This parameter sets the inter-character timeout that is used by the TIM. The value n represents the amount of time in hundredths of a second the TIM will wait for each byte within a response. The value required depends greatly on the meters processing speed, the requirements being placed on the meter by the programming, Default Value = 100.

      2) Place the .cfg file in the ..\MV90xi\master folder.

      3) Specify the TIM configuration file name (e.g. 8600p.CFG) in the 'TIM Config File' field under the More tab of the concerned recorder:


      Attachments

      (Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/1af4a7ac1af4a7f5c12577160010b142/fl_block_5/0.1A60?OpenElement&FieldElemFormat=gif)
      Date Created: April 30, 2010
      Last Revised: April 30, 2010
      Public
      Original Author: TL
      All content © 1992-2010 Schneider Electric


      Legacy KB System (APS) Data: RESL202148 V1.0, Originally authored by MiNe on 05/01/2010, Last Edited by MiNe on 05/01/2010
      Related ranges: OS & related Third Party PRODUCTS for Power Mangement Systems