OptiLine 50. Plastic Trunking base 140 mm + Top cover. With 50 mm front in lower compartment
ol50 inst.trunking 2-comp 140 hf
OptiLine 50. Plastic Trunking base 140 mm + Top cover. Without 50 mm front in lower compartment
OptiLine 50. Plastic Trunking base 140 mm + Top cover. With 50 mm front in lower compartment
ol50 inst.trunking 2-comp 140 hf
OptiLine 50. Plastic Trunking base 140 mm + Top cover. Without 50 mm front in lower compartment

Optiline 50 InstAllation Trunking, 140 X 63 Mm, Plastic, 2.5 M

Catalogue Number: INS12400

Discontinued

OptiLine 50. Plastic Trunking base 140 mm + Top cover. With 50 mm front in lower compartment
ol50 inst.trunking 2-comp 140 hf
OptiLine 50. Plastic Trunking base 140 mm + Top cover. Without 50 mm front in lower compartment
OptiLine 50. Plastic Trunking base 140 mm + Top cover. With 50 mm front in lower compartment
ol50 inst.trunking 2-comp 140 hf
OptiLine 50. Plastic Trunking base 140 mm + Top cover. Without 50 mm front in lower compartment
Colour:
Colour: Per UOM Std.
  • 1 M

Specifications

hide show
Range of product
OptiLine 50
Product or component type
installation trunking
Colour tint
white (RAL 9010)
Quantity per set
10 m
Compartment partitioning
2 compartments
Trunking dimension
140 x 63 mm
Trunking material
plastic
Front opening size
50 mm
Fixing mode
  • by brackets
  • screw-fixed
    • Material
      PC/ABS
      Length
      2500 mm
      Height
      140 mm
      Width
      63 mm
      Ambient air temperature for operation
      -25-60 °C
      Environmental characteristic
      halogen free
      IP degree of protection
      IP40
      IK degree of protection
      IK07
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP090920EN
      Warranty
      18 months

      Frequently Asked Questions

      hide show

      What is the part number for an end stop for the Optiline 50 ducting , INS12300?

      The part number for an end stop for the Optiline 50 ducting , INS12300 is - INS12304

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS12304
      User-added image

      What is the key lock replacement for a INS1250?

      You can replace the key lock with the following models

      33190 (https://www.schneider-electric.com/en/product/33190/ronis-keylock---for-masterpact-nt---off-position---2-same-key---el24135/)
      41950 (https://www.schneider-electric.com/en/product/41950/2-key-lock-%2B-1-flat-key).


       

      What is the part number for long terminal shields to suit the INS100

      The long terminal shields are the 28958 which is a set of 2.

      Can part number INS51245 be installed in concrete?

      No part number INS51245 can not be installed in concrete.

      What is the part code for INS switch with an escutcheon for the INS100

      No there is no escutcheon for the INS40 - 160 range

      What is the connection kit for INS400 (31110) to CNS630 chassis

      CNS63CK - This kit is only  required to maintain the same escutcheon level for the incoming and outgoing devices -  
      The 630A CNS-Powerpact chassis can be connected directly to an Interpact INS400 to INS630 switch disconnector

      What are the dimensions of the INS400 single handle transfer switch 31150?

      205mm x 395mm x 155mm (H x W x D) excluding the handle.
      Overall depth with standard handle is 213mm.
      See attached.

      When running redundant 140CPS124 00 power supplies, is it possible to replace a failed 140CPS124 00 with the 140CPS124 20?

      No. Each power supply making up the redundant pair has to be of the same type. Mixing power supply models may result in unintended operation.







      R-20818

      What is the code extended front rotary handle / shaft for an INS250?

      Code = 31050

      What are the terminal spreaders that can be used for the INS320?

      LV432490 - 52.5mm Pitch
      Please follow the link for the data sheet:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432490
       

      What is the part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points?

      The part number for a pole , floor to ceiling , single sided , tension mounted , with 4 power outlets and 4 data points is - INS43406 & INS62024 & INS62027

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS43406
      https://www.clipsal.com/Trade/search-results?q=INS62024
      https://www.clipsal.com/Trade/search-results?q=INS62027
      User-added image

      Which is the neutral pole on a 4-pole Masterpact NW?

      Issue:
      Which is the neutral pole on a 4-pole Masterpact NW?

      Product Line:
      Masterpact NW NT

      Resolution:
      By default, the neutral is the left pole.  It may be ordered as a right-pole neutral and if so the catalog number will have a "B" in position 19 or 20.
      The neutral is protected and a neutral current transformer NCT is not required if sensing ground-fault.


       

      How to Change the byte´s Order for Floating Point under Modnet Protocol in PLS

      The tag with Real and Long data type is 2 words (4 Bytes) format. It is allowed to change the reading order of the bytes on PLS by change the parameter in citect.ini file for MODNET protocol.
      Modnet20 is specified for TSX Quantum PLC ranges. These protocol options will select the correct addressing modes, select certain INI values and other settings to provide compatibility with these devices without the need to set any other special parameters. Base on the default setting, some of parameters cannot be changed. Therefore, it is recommended to use Modnet protocol.

      Please use the parameter to change the byte order for Real data type
      [MODNET]
      FloatMode = x where x is 0, 1, 2 or 3
      Allowable Values:
      0: Order of bytes = 1 0 3 2
      1: Order of bytes = 3 2 1 0
      2: Order of bytes = 0 1 2 3
      3: Order of bytes = 2 3 0 1
      Default Value: 0

      In the MODNET protocol, LONG data types default to a simplified implementation, with a shortened range of 0 to 655,359,999 - mode 0. Mode 2 has the same range as mode 0, but with the register order swapped. Mode 1 supports the full LONG range of -2,147,483,648 to +2,147,483,647. Mode 3 has the same range as mode 1, but with the register order swapped.
      When using the MODBUS protocol, CitectSCADA combines two registers to store a long data type in a PLC. The way in which it does this is defined by this parameter in the "citect.ini" file.

      [MODNET]
      LongDataType = y where y is 0, 1, 2 or 3
      Allowable Values:
      0 - implies 10,000 * low register + high register
      1 - implies 65,536 * low register + high register
      2 - implies 10,000 * high register + low register
      3 - implies 65,536 * high register + low register
      Default Value: 3


      Last Revised: 09 Apr 2010
      Original Author: EF
      Public
      All content © 1992-2010 Schneider Electric


      Legacy KB System (APS) Data: RESL201943 V1.0, Originally authored by KBAdPM on 04/13/2010, Last Edited by KBAdPM on 04/13/2010
      Related ranges: PowerLogic SCADA 7.1

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page