OptiLine 50 Trunking, Bend 90 degree 100 mm.

OptiLine 50 Bend, 80 x 63 mm, PC/ABS

Catalogue Number: INS12103
OptiLine 50 Trunking, Bend 90 degree 100 mm.
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
OptiLine 50
Product or component type
bend
Quantity per set
1 piece
Colour tint
white (RAL 9010)
Trunking dimension
80 x 63 mm
Trunking material
  • aluminium
  • plastic
    • Fixing mode
      screw-fixed
      Material
      PC/ABS
      Length
      102 mm
      Height
      102 mm
      Width
      63 mm
      Ambient air temperature for operation
      -25-60 °C
      IP degree of protection
      IP40
      IK degree of protection
      IK07
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP090918EN
      Circularity Profile
      N/A
      Warranty
      18 months

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Movies

      • Technical Data Catalogues

      • Product Environmental

      • Installation Instruction

      • Operating Manuals

      • Specifications

      • Declaration of Conformity

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the key lock replacement for a INS1250?

      You can replace the key lock with the following models

      33190 (https://www.schneider-electric.com/en/product/33190/ronis-keylock---for-masterpact-nt---off-position---2-same-key---el24135/)
      41950 (https://www.schneider-electric.com/en/product/41950/2-key-lock-%2B-1-flat-key).


       

      What is the part number for an end stop for the Optiline 50 ducting , INS12300?

      The part number for an end stop for the Optiline 50 ducting , INS12300 is - INS12304

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=INS12304
      User-added image

      Is there a screed box to suit the INS62034 floor box?

      Yes, there is a screed box to suit the INS62034 floor box. The part number is INS62039.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS62039


       

      Does part no INS43503 accommodate standard double GPO

      Yes Part no is INS43503

      for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS43503

      User-added image

      What is the load rating for part number INS62043?

      Load rating for part number INS62043 is 200kg.

      What is the part number for the lid to suit the INS62043 floor box?

      The part number for the lid to suit the INS62043 floor box is INS62041.

      Some of the key features are:
      • Aluminium alloy lid with stainless steel finish
      • Lid working range opens to 80°
      • Shearsafe technology includes soft-close lid to protect users and cables

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS62041




       

      Part number for the lid to suit the INS62043 floor box?

      The part number for the lid to suit the INS62043 floor box is INS62041.

      Some of the key features are:
      • Aluminium alloy lid with stainless steel finish
      • Lid working range opens to 80°
      • Shearsafe technology includes soft-close lid to protect users and cables

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS62041




       

      Do you have a Floor box that will take 2 double GPOs?

      The INS62043 floor box can take up to 4 double outlets.

      What is the part number for a flush metal lid floor box?

      the part number is INS62043

      What is the code extended front rotary handle / shaft for an INS250?

      Code = 31050

      Is there a replacement lid for an INS62043?

      The replacement lid for the INS62043 is a INS62041.

      For further details on this range, follow the link below.
      https://www.clipsal.com/Trade/search-results?q=ins62043

      User-added image

      What are the terminal spreaders that can be used for the INS320?

      LV432490 - 52.5mm Pitch
      Please follow the link for the data sheet:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LV432490
       

      R013_How to make a diagnostic on TesysT to start the network

      Goals and Symptoms

       

      This technical resolution describes how to make a diagnostic on TesysT when the network port does not start

      Causes and Fixes

      This technical resolution describes how to make a diagnostic on TesysT when the network port does not start

      Attachments

      (Removed File URL: 190973_4C8E/R013_How_to_make_a_diagnostic_on_TesysT_to_start_the_network.pdf)(Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/0ae937fdfe9a409dc12575a100529a71/fl_block_5/0.5AA?OpenElement&FieldElemFormat=gif)


      Legacy KB System (APS) Data: RESL190973 V3.0, Originally authored by MiFo on 02/05/2008, Last Edited by MiFo on 04/23/2009
      Related ranges: TeSys T

      How to deactivate the Earth Fault protection in Micrologic 6.0 trip unit of Masterpact ACB.

      To deactivate the Earth Fault protection function in Micrologic 6.0 trip unit, follow the below procedure:

      1. On the Masterpact Air Circuit Breaker (ACB), you have to put the jumpers in between F1-M1 and M2-M3 terminals.
       
      2. Remove the External Sensor from the busbars and disconnect the wiring between Sensor and the ACB. 
       
      In case External sensor can't be removed from the busbars then remove the wires between Sensor and ACB. Next jumper the sensor terminals T1-T2 and T3-T4.
       
      Refer the attached document describing the procedure.

      What is the part number for the discontinued Moduline flush floor box with a flush stainless steel lid?

      Unfotrunately this part is no longer available and has been discontinued.
      The New Floor Box range is the Optiline INS range. For the closest alternative to this moduline floorbox wouled be a INS62043.
      Dimensions are 310.5mm (L) X 310.5mm (W) X 105mm (D).
      The cut out is 293mm (L) X 293mm (W) X 105mm (D).
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=INS62043





      The part number for the discontinued moduline flush floor box with a flush stainless steel lid is FFBSSF4PTD.

      Moduline Floor Boxes are available in square, rectangular and circular designs and manufactured in a variety of materials to suit your application. A selection of outlet configurations is available to accommodate power, voice/data and audiovisual requirements. To ensure the appropriate lid is chosen for the intended purpose, Moduline Floor Boxes also provide a wide choice of lid options.

      FFBSSF4PTD replaces FFBSSFFLA and FFBCA4PTD

      Some of its key features are:
      • 198 Length x 198 Width x 90 Depth mm dimension
      • Complete with stainless steel flush lid
      • 4 power and provision for 4 data