MASTER YOUR CASTLE with your new build or reno project
Enter competition
GV4PE02N6

GV4PE115B6

Motor Breaker GV4PE Thermal/Magnetic 115A 25kA Lug Terminal

GV4PE02N6
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
  • Everlink power connections with patented creep-compensation technology
  • One size up to 55KW at 415 VAC
  • Wide overload setting for easy selection and reducing the stock
  • 3 level short circuit breaking capacity (25KA, 50KA and 100KA)
  • Robust Rotary handle (Direct, side and extended)
  • Green Premium ecoLabel
Range
TeSys
Product name
TeSys GV4
Device short name
GV4PE
Product or component type
circuit breaker
Device application
motor protection
Protection type
  • short-circuit
  • overload
  • phase loss
  • short time short-circuit protection
  • ground fault protection
  • phase unbalance
    • Utilisation category
      category A
      Suitability for isolation
      yes conforming to IEC 60947-1
      Poles description
      3P
      [Ue] rated operational voltage
      690 V AC 50/60 Hz conforming to IEC 60947-2
      [In] rated current
      115 A
      Trip unit technology
    • electronic
    • thermal-magnetic
      • Magnetic tripping current
        1955-1955 A
        [Isd] short-time pick-up adjustment range
        13 x Ir
        Thermal protection adjustment range
        65-115 A
        Motor tripping class
      • 10
      • 20
        • Phase failure sensitivity
          yes conforming to IEC 60947-4-1
          Breaking capacity
        • Icu 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
        • Icu 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
        • Icu 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
        • Icu 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
        • 35 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
        • 35 kA at 240 V AC 50/60 Hz conforming to UL 60947
        • 18 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
        • 14 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
          • [Ics] rated service breaking capacity
          • 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
          • 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
          • 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
          • 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • [Uimp] rated impulse withstand voltage
              [Ui] rated insulation voltage
              800 V conforming to IEC 60947-2
              Mechanical durability
              40000 cycles
              Electrical durability
            • 10000 cycles for AC-3 at 440 V In/2
            • 5000 cycles for AC-3 at 440 V In
              • Motor power kW
              • 37-37 kW at 400...415 V AC 50/60 Hz
              • 45-45 kW at 400...415 V AC 50/60 Hz
              • 55-55 kW at 400...415 V AC 50/60 Hz
              • 45-45 kW at 500 V AC 50/60 Hz
              • 55-55 kW at 500 V AC 50/60 Hz
              • 75-75 kW at 500 V AC 50/60 Hz
              • 75-75 kW at 660...690 V AC 50/60 Hz
              • 90-90 kW at 660...690 V AC 50/60 Hz
              • 110-110 kW at 660...690 V AC 50/60 Hz
                • Control type
                  toggle
                  Rotary handle padlocking
                  with a lock accessory
                  Number of slots
                • 1 slot(s) for alarm switch for fault signalling contact, plug-in
                • 1 slot(s) for voltage release for electrical remote tripping, plug-in
                • 1 slot(s) for auxiliary switch for open/close contact, plug-in
                  • Local signalling
                  • flashing LED (green)ready:
                  • LED (red)alarm (T° >95%):
                  • green indicatorpresence of auxiliary contacts:
                    • Standards
                    • CSA C22.2 No 60947-4-1
                    • UL 60947-4-1
                    • EN/IEC 60947-2
                    • EN/IEC 60947-4-1
                      • Product certifications
                      • IEC
                      • UL
                      • CSA
                      • CCC
                      • EAC
                      • ATEX
                      • BV
                        • Quality labels
                          CE
                          Mounting mode
                        • by clips
                        • by screws
                          • Mounting support
                          • 75 mm symmetrical DIN rail
                          • plate
                          • 35 mm symmetrical DIN rail
                            • Connections - terminals
                              lugs-ring terminals
                              Connection pitch
                              27 mm
                              Tightening torque
                            • 9-9 N.m for 16-95 mm²
                            • 5-5 N.m for 1.5-10 mm²
                              • Width
                                81 mm
                                Height
                                155 mm
                                Depth
                                116 mm
                                Net weight
                                1.45 kg
                                Ambient air temperature for storage
                                -50-85 °C
                                Ambient air temperature for operation
                                -25-70 °C
                                Operating altitude
                              • 0...2000 m without derating
                              • 2000...5000 m with derating
                                • IP degree of protection
                                  IP40 front face conforming to IEC 60529
                                  IK degree of protection
                                  IK07 conforming to IEC 62262
                                  Pollution degree
                                  3 conforming to IEC 60947-1
                                  Tropicalisation
                                  2 conforming to IEC 68-2
                                  Mechanical robustness
                                • vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
                                • vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
                                • shocks: 15 gn 11 ms conforming to IEC 60068-2-27
                                  • Sustainable offer status
                                    Green Premium product
                                    REACh Regulation
                                    Free of Substances of Very High Concern above the threshold
                                    EU RoHS Directive
                                    Compliant
                                    Mercury free
                                    Yes
                                    RoHS exemption information
                                    Yes
                                    China RoHS Regulation
                                    Product out of China RoHS scope. Substance declaration for your information
                                    Environmental Disclosure
                                    ENVPEP1704004EN
                                    Circularity Profile
                                    ENVEOLI1704004EN
                                    WEEE
                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                    California proposition 65
                                    WARNING: This product can expose you to chemicals including: which is known to the State of California to cause Not determined harm. For more information go to www.p65warnings.ca.gov
                                    Warranty
                                    18 months