Motor Breaker GV4PE Thermal/Magnetic 7A 50kA Everlink Terminal

Motor Breaker GV4PE Thermal/Magnetic 7A 50kA Everlink Terminal

Motor Breaker GV4PE Thermal/Magnetic 7A 50kA Everlink Terminal

Item Number: GV4PE07N

Retail
$1,737.41
RRP (Inc. GST)

Product Dimensions

Width icon

Width81 mm

Height icon

Height155 mm

Depth icon

Depth116 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

circuit breaker

Device application

motor protection

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Protection type

  • overload
  • ground fault protection
  • short-circuit
  • phase loss
  • short time short-circuit protection
  • phase unbalance
    • [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      [In] rated current

      7 A

      Mechanical durability

      40000 cycles

      Electrical durability

    • 40000 cycles for AC-3 at 440 V In/2
    • 40000 cycles for AC-3 at 440 V In
      • Control type

        toggle

        Local signalling

      • flashing LED (green)ready:
      • LED (red)alarm (T° >95%):
      • green indicatorpresence of auxiliary contacts:
        • Standards

        • EN/IEC 60947-4-1
        • EN/IEC 60947-2
        • UL 60947-4-1
        • CSA C22.2 No 60947-4-1
          • Product certifications

          • IEC
          • UL
          • CSA
          • CCC
          • EAC
          • ATEX
          • EU-RO MR
            • Mounting mode

            • by clips
            • by screws
              • Mounting support

              • 75 mm symmetrical DIN rail
              • 35 mm symmetrical DIN rail
              • plate
                • Connections - terminals

                • top 1 EverLink BTR screw connectors wire size 1.5-70 mm², solid
                • top 1 EverLink BTR screw connectors wire size 1.5-50 mm², flexible
                • bottom 1 EverLink BTR screw connectors wire size 2.5-95 mm², solid
                • bottom 1 EverLink BTR screw connectors wire size 2.5-70 mm², flexible
                  • Wire stripping length

                    20 mm

                    Width

                    81 mm

                    Height

                    155 mm

                    Depth

                    116 mm

                    Net weight

                    1.45 kg

                    Ambient air temperature for storage

                    -50-85 °C

                    Ambient air temperature for operation

                    -25-70 °C

                    IP degree of protection

                    IP40 front face conforming to IEC 60529

                    IK degree of protection

                    IK07 conforming to IEC 62262

                    EU RoHS Directive

                    Compliant

                    Mercury free

                    Yes

                    RoHS exemption information

                    Yes

                    China RoHS Regulation

                    Product out of China RoHS scope. Substance declaration for your information

                    Environmental Disclosure

                    ENVPEP1704004EN

                    Circularity Profile

                    ENVEOLI1704004EN

                    Others

                    Product name

                    TeSys GV4

                    Device short name

                    GV4PE

                    Utilisation category

                    category A

                    Suitability for isolation

                    yes conforming to IEC 60947-1

                    Poles description

                    3P

                    Trip unit technology

                  • electronic
                  • thermal-magnetic
                    • Magnetic tripping current

                      119-119 A

                      [Isd] short-time pick-up adjustment range

                      13 x Ir

                      Thermal protection adjustment range

                      2.9-7 A

                      Motor tripping class

                    • 10
                    • 20
                      • Phase failure sensitivity

                        yes conforming to IEC 60947-4-1

                        Breaking capacity

                      • Icu 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                      • 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
                      • 65 kA at 240 V AC 50/60 Hz conforming to UL 60947
                      • 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
                      • Icu 8 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                      • Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                      • 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
                        • [Ics] rated service breaking capacity

                        • 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
                        • 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
                        • 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
                        • 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
                        • 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
                        • 2 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
                          • [Uimp] rated impulse withstand voltage

                            [Ui] rated insulation voltage

                            800 V conforming to IEC 60947-2

                            Motor power kW

                          • 1.5-1.5 kW at 400...415 V AC 50/60 Hz
                          • 2.2-2.2 kW at 400...415 V AC 50/60 Hz
                          • 2.5-2.5 kW at 400...415 V AC 50/60 Hz
                          • 3-3 kW at 400...415 V AC 50/60 Hz
                          • 2.2-2.2 kW at 500 V AC 50/60 Hz
                          • 2.5-2.5 kW at 500 V AC 50/60 Hz
                          • 3-3 kW at 500 V AC 50/60 Hz
                          • 4-4 kW at 500 V AC 50/60 Hz
                          • 3-3 kW at 660...690 V AC 50/60 Hz
                          • 4-4 kW at 660...690 V AC 50/60 Hz
                          • 5.5-5.5 kW at 660...690 V AC 50/60 Hz
                          • 7.5-7.5 kW at 660...690 V AC 50/60 Hz
                            • Rotary handle padlocking

                              with a lock accessory

                              Number of slots

                            • 1 slot(s) for alarm switch for fault signalling contact, plug-in
                            • 1 slot(s) for voltage release for electrical remote tripping, plug-in
                            • 1 slot(s) for auxiliary switch for open/close contact, plug-in
                              • Quality labels

                                CE

                                Connection pitch

                                27 mm

                                Tightening torque

                              • 9-9 N.m for 16-95 mm²
                              • 5-5 N.m for 1.5-10 mm²
                                • Operating altitude

                                • 0...2000 m without derating
                                • 2000...5000 m with derating
                                  • Pollution degree

                                    3 conforming to IEC 60947-1

                                    Tropicalisation

                                    2 conforming to IEC 68-2

                                    Mechanical robustness

                                  • vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
                                  • vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
                                  • shocks: 15 gn 11 ms conforming to IEC 60068-2-27
                                    • Package 1 Weight

                                      1.67 kg

                                      Package 1 Height

                                      17 cm

                                      Package 1 width

                                      11 cm

                                      Package 1 Length

                                      22 cm

                                      WEEE

                                      The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                                      PVC free

                                      Yes

                                      Halogen content performance

                                      Halogen free plastic parts product
                                      Show all specifications

                                      Frequently Asked Questions

                                      hide show

                                      Are explosion proof enclosures available for GV manual motor starters.

                                      Issue:
                                      NEMA 7/9 rated enclosure for GV manual motor starters

                                      Product Line:
                                      Tesys GV Motor Starters and Protectors

                                      Environment:
                                      TeSys™ GV Manual Starters and Protectors

                                      Resolution:
                                      No hazardous duty enclosures are available for the GV product line.
                                      For explosion proof applications consider the Class 2510 Type M or Type T offering.

                                      GV2P disconnect options

                                      Issue:
                                      What is the product number for a complete through-the-door disconnect device for a GV2P

                                      Product Line:
                                      GV2P Manual Starters and Protectors

                                      Environment:
                                      US product

                                      Cause:
                                      Digest 176 is unclear as to what is a complete mechanism with shaft and handle

                                      Resolution:
                                      There are three devices which include mechanism, shaft and handle:
                                      GV2APN01 has a NEMA 1, 12 rating and is black
                                      GV2APN02 has a NEMA 1, 12 rating and is red/yellow
                                      GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

                                      What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                                      Issue:
                                      Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                                      Product Line:
                                      Contactors and Starters IEC

                                      Environment:
                                      Tesys D contactors and GV manual starters

                                      Cause:
                                      Spacer required

                                      Resolution:
                                      Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                                      Can a GV2AF3 or GV2AF4 interconnection block work on a contactor with a DC coil?

                                      Issue:
                                      Mounting adaptor for GV2 and LC1D contactor

                                      Product Line:
                                      Motor Starters and Protectors

                                      Environment:
                                      TeSys GV Manual Starter and Protectors
                                      Tesys D Contactors
                                       
                                      Resolution:
                                      The GV2AF3 clip has to be moved to the DC position to accommodate the contactor with a DC coil.

                                      Can the GV* starters be used on 50 hertz applications?

                                      Issue:
                                      GV* Starter for 50/60hz application

                                      Product Line:
                                      Motor Starters and Protectors

                                      Environment:
                                      PowerPact™ Manual Starters

                                      Resolution:
                                      Yes, these starters are rated for 50/60 hertz.

                                      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                                      Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

                                      Product Line:
                                      GV3 manual motor starters, IEC

                                      Resolution:
                                      The standard GV3 accessories will work on this device.

                                      Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                                      Issue:
                                      Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                                       
                                      Product Line:

                                      Tesys GV Manual Starter and Protectors

                                      Environment:
                                      TeSys GV, GVA, GV2, GV3P

                                      Resolution:
                                      These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                                      Is a padlocking device available for the GV2MC** type enclosures?

                                      Issue:
                                      Padlocking device for GV2MC Enclosures

                                      Product Line:
                                      TeSys GV2 Manual Starters and Protectors

                                      Environment:
                                      n/a

                                      Resolution:
                                      Yes, use the GV2V01. When this is padlocked, the starter is automatically in and will remain in the OFF position.