Quantcast

TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.1¦0.16 A

TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.1¦0.16 A

TeSys GV2 Motor Circuit Breaker, Thermal Magnetic, 0.1¦0.16 A

Item Number: GV2P01

Retail
$510.65
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth97 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys GV2

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with 2 x M4 screws)
    • Control type

      rotary knob

      [In] rated current

      0.16 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 440 V

      Height

      89 mm

      Width

      45 mm

      Depth

      97 mm

      Standards

    • EN/IEC 60947-2
    • EN/IEC 60947-4-1
    • UL 60947-4-1
    • CSA C22.2 No 60947-4-1
      • Product certifications

      • IECEE CB Scheme
      • UL
      • CSA
      • CCC
      • EAC
      • ATEX
      • BV
      • LROS (Lloyds register of shipping)
      • DNV-GL
      • RINA
        • IP degree of protection

          IP20 conforming to IEC 60529

          IK degree of protection

          IK04

          Ambient air temperature for operation

          -20-60 °C

          Ambient air temperature for storage

          -40-80 °C

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP121004EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

          Others

          Product name

          TeSys GV2

          Device short name

          GV2P

          Trip unit technology

          thermal-magnetic

          Poles description

          3P

          Network type

          AC

          Utilisation category

        • AC-3 conforming to IEC 60947-4-1
        • category A conforming to IEC 60947-2
          • Network frequency

            50/60 Hz conforming to IEC 60947-4-1

            Operating position

            any position

            Breaking capacity

          • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
          • 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • [Ics] rated service short-circuit breaking capacity

            • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
              • Trip unit rating

                0.1-0.16 A

                Magnetic tripping current

                1.5-1.5 A

                [Ui] rated insulation voltage

                690 V AC 50/60 Hz conforming to IEC 60947-2

                [Ith] conventional free air thermal current

                0.16 A conforming to IEC 60947-4-1

                [Uimp] rated impulse withstand voltage

                Power dissipation per pole

                2.5 W

                Maximum operating rate

                25 cyc/h

                Rated duty

                continuous conforming to IEC 60947-4-1

                Direct connector

                without

                Tightening torque

                1.7 N.m on screw clamp terminals

                Suitability for isolation

                yes conforming to IEC 60947-1

                Phase failure sensitivity

                yes conforming to IEC 60947-4-1

                Compatibility code

                GV2P

                Protective treatment

                TH

                Fire resistance

                960 °C conforming to IEC 60695-2-1

                Operating altitude

                2000 m

                Unit Type of Package 1

                PCE

                Number of Units in Package 1

                1

                Package 1 Weight

                268 g

                Package 1 Height

                4.7 cm

                Package 1 width

                9 cm

                Package 1 Length

                9.4 cm

                WEEE

                The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                Show all specifications

                Documents & downloads

                hide show
                Filter items
                • All

                • CAD Files and Packs

                • Product Brochures

                • Technical Data Catalogues

                • Installation Instruction

                • Product Environmental

                • Data Bulletin

                • Technical Drawing

                • Certificates (MSDS)

                • eTechPub

                • Declaration of Conformity

                Frequently Asked Questions

                hide show

                Can the GV* starters be used on 50 hertz applications?

                Issue:
                GV* Starter for 50/60hz application

                Product Line:
                Motor Starters and Protectors

                Environment:
                PowerPact™ Manual Starters

                Resolution:
                Yes, these starters are rated for 50/60 hertz.

                This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                GV2G05 does not line up with GV2P08 terminals when using GV2G45. Is another part required?

                Connector diagram in catalogue only shows GV2ME. As the GV2P (and GV2L) are deeper than the GV2ME the terminals will not line up with the terminals of the GV2G05

                For GV2P height compensation bracket GV1F03 is required (not shown in diagram). This will raise GV1F03 so the terminals are in line with the terminals of the GV2P.

                Datasheet of item below:
                https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=GV1F03

                What items does the GV2PC02 enclosure suit?

                The GV2PC02 is for GV2P and GV2L, 0.55 to 15kW.

                What is the hole size of the padlock provision for a GV2P starter?

                Issue:
                Padlock hole diameter on GV2P

                Product Line:
                GV2 Manual Motor Protectors

                Environment:
                All GV2P, rotary handle. 

                Cause:
                n/a

                Resolution:
                There are provisions for one padlock only, the hole size is approximately 6mm.  You can add a GV2V03 padlock attachment that will allow up to 6 padlocks for Lock out Tag out applications.

                What is the operation of the GV2AD fault signalling contacts of the GV2 motor protection circuit breakers?

                GV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L Motor protection circuit breakers (MPCB) can be fitted with the following optional fault indicating contact blocks:
                 

                GVAD0110
                GVAD0101
                GVAD1010
                GVAD1001

                These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts

                GVAD0110

                A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized

                A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                GVAD0101

                A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.

                A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs. 

                GVAD1010 

                A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energized and open when the device is de-energized.

                A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                 

                GVAD1001

                A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energized and open when the device is energized.

                A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs. 
                 


                The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energized position and the energized position.

                The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.