Quantcast

TeSys GV2 Circuit Breaker Thermal Magnetic, 1...1.6 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 1...1.6 A, Screw Clamp Terminals

TeSys GV2 Circuit Breaker Thermal Magnetic, 1...1.6 A, Screw Clamp Terminals

Item Number: GV2ME06

Retail
$470.95
RRP (Inc. GST)

Product Dimensions

Width icon

Width45 mm

Height icon

Height89 mm

Depth icon

Depth78.5 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Range of product

TeSys GV2

Product or component type

circuit breaker

Device application

motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

  • 35 mm symmetrical DIN rail: clipped
  • panel: screwed (with adaptor plate)
    • Control type

      push-button

      [In] rated current

      1.6 A

      [Ue] rated operational voltage

      690 V AC 50/60 Hz conforming to IEC 60947-2

      Mechanical durability

      100000 cycles

      Electrical durability

      100000 cycles for AC-3 at 440 V

      Height

      89 mm

      Width

      45 mm

      Depth

      78.5 mm

      Net weight

      0.26 kg

      Standards

    • EN/IEC 60947-2
    • EN/IEC 60947-4-1
    • CSA C22.2 No 60947-4-1
    • UL 60947-4-1
      • Product certifications

      • IECEE CB Scheme
      • UL
      • CSA
      • CCC
      • EAC
      • ATEX
      • BV
      • LROS (Lloyds register of shipping)
      • DNV-GL
      • RINA
        • IP degree of protection

          IP20 conforming to IEC 60529

          IK degree of protection

          IK04

          Ambient air temperature for operation

          -20-60 °C

          Ambient air temperature for storage

          -40-80 °C

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP121004EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

          Others

          Product name

          TeSys GV2

          Device short name

          GV2ME

          Trip unit technology

          thermal-magnetic

          Poles description

          3P

          Network type

          AC

          Utilisation category

        • AC-3 conforming to IEC 60947-4-1
        • category A conforming to IEC 60947-2
          • Network frequency

            50/60 Hz conforming to IEC 60947-4-1

            Operating position

            any position

            Motor power kW

          • 0.37-0.37 kW at 400/415 V AC 50/60 Hz
          • 0.37-0.37 kW at 500 V AC 50/60 Hz
          • 0.75-0.75 kW at 690 V AC 50/60 Hz
          • 0.55-0.55 kW at 400/415 V AC 50/60 Hz
          • 0.55-0.55 kW at 500 V AC 50/60 Hz
          • 0.75-0.75 kW at 500 V AC 50/60 Hz
          • 1.1-1.1 kW at 690 V AC 50/60 Hz
            • Breaking capacity

            • 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
            • 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • [Ics] rated service short-circuit breaking capacity

              • 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
              • 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
                • Trip unit rating

                  1-1.6 A

                  Magnetic tripping current

                  22.5-22.5 A

                  [Ui] rated insulation voltage

                  690 V AC 50/60 Hz conforming to IEC 60947-2

                  [Ith] conventional free air thermal current

                  1.6 A conforming to IEC 60947-4-1

                  [Uimp] rated impulse withstand voltage

                  Power dissipation per pole

                  2.5 W

                  Maximum operating rate

                  25 cyc/h

                  Rated duty

                  continuous conforming to IEC 60947-4-1

                  Direct connector

                  without

                  Tightening torque

                  1.7 N.m on screw clamp terminals

                  Suitability for isolation

                  yes conforming to IEC 60947-1

                  Phase failure sensitivity

                  yes conforming to IEC 60947-4-1

                  Compatibility code

                  GV2ME

                  Protective treatment

                  TH

                  Fire resistance

                  960 °C conforming to IEC 60695-2-1

                  Operating altitude

                  2000 m

                  Unit Type of Package 1

                  PCE

                  Number of Units in Package 1

                  1

                  Package 1 Weight

                  253.9 g

                  Package 1 Height

                  4.8 cm

                  Package 1 width

                  8.6 cm

                  Package 1 Length

                  9.3 cm

                  WEEE

                  The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                  Show all specifications

                  Documents & downloads

                  hide show
                  Filter items
                  • All

                  • CAD Files and Packs

                  • Product Brochures

                  • Technical Data Catalogues

                  • Installation Instruction

                  • Handout

                  • Product Environmental

                  • Data Bulletin

                  • Technical Drawing

                  • Certificates (MSDS)

                  • eTechPub

                  • Declaration of Conformity

                  Frequently Asked Questions

                  hide show

                  Can the GV* starters be used on 50 hertz applications?

                  Issue:
                  GV* Starter for 50/60hz application

                  Product Line:
                  Motor Starters and Protectors

                  Environment:
                  PowerPact™ Manual Starters

                  Resolution:
                  Yes, these starters are rated for 50/60 hertz.

                  This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

                  Can GVAE1, GVAE11 or GVAE20 be used with GV3 starters?

                  Issue:
                  Are the front mount auxiliary contacts GVAE1, GVEA11 and GVAE20 be used for GV3M devices?
                   
                  Product Line:

                  Tesys GV Manual Starter and Protectors

                  Environment:
                  TeSys GV, GVA, GV2, GV3P

                  Resolution:
                  These auxiliary contacts can only be used with the rotary handled GV3P devices. They cannot be applied with the pushbutton GV3M devices.

                  What would be the part number for an enclosure for the GV2ME20

                  What is the part number for the spacer used with the LC*D09 through LC*D32 Contactor and the GV2AF3 combination block when the GV2 Motor Circuit Protector is mounted on din rail and the contactor hangs below it?

                  Issue:
                  Identifying the spacer part number for use with a LC*D, GV2AF3, and GV2 device combination

                  Product Line:
                  Contactors and Starters IEC

                  Environment:
                  Tesys D contactors and GV manual starters

                  Cause:
                  Spacer required

                  Resolution:
                  Compensation plate catalog number GV1F03, requires 2 pieces snap together.

                  GV2G05 does not line up with GV2P08 terminals when using GV2G45. Is another part required?

                  Connector diagram in catalogue only shows GV2ME. As the GV2P (and GV2L) are deeper than the GV2ME the terminals will not line up with the terminals of the GV2G05

                  For GV2P height compensation bracket GV1F03 is required (not shown in diagram). This will raise GV1F03 so the terminals are in line with the terminals of the GV2P.

                  Datasheet of item below:
                  https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=GV1F03

                  How many auxiliary contact modules can be installed on the GV3ME__ manual starter?

                  Issue:
                  GV2 and GV3 number of aux switches?

                  Product Line:
                  Manual Starters

                  Environment: 
                  GV2 GV3 manual motor starters, IEC

                  Resolution:
                  One right side mount instantaneous auxiliary module and one internal mount fault signaling auxiliary module.
                  Show More