Specifications

hide show
Range
Acti 9
Device short name
MSC 18
Product or component type
chassis
Device application
distribution
Range compatibility
Acti 9 Isobar B distribution board
[In] rated current
250 A
Short-circuit withstand
25 kA 0.1 s
[Icw] rated short-time withstand current
25 kA
Number of ways
  • 1 way (incomer) - 3P
  • 96 (outgoer)
    • Number of poles
      96 18 mm
      Length
      866 mm
      Width
      215 mm
      Busbar pitch
      27 mm
      EU RoHS Directive
      Not applicable, out of EU RoHS legal scope

      Documents & downloads

      hide show
      Filter items
      • All

      • Technical Data Catalogues

      • Specifications

      Frequently Asked Questions

      hide show

      What is the PAN assembly for C120 MCCB's

       The part code is C125123

      do we do modena 32amp unprinted mech

      PDL881M32SN - Unprinted, Amber Neon Pre-fitted.

      What is the part code for a 96way pan assembly (Chassis) ?

      C325963TFW. Fits C60 MCB's x 96 Poles. Total Rating = 250A

      How many 3 pole C120 breakers can be supplied from the C125123?

      That is a 3 phase, 12 pole supply with 27mm spcaing. It will supply up to 4x 3 pole breakers.

      What distribution board is required for the CH25843 chassis?

      For the customized distribution board for 72 pole (18 mm) and 12 pole (27 mm) chassis, you need to submit request for a quote to "au.estimating@schneider-electric.com". Our Standard distribution board only goes up to 60 pole (18 mm) and 12 pole (27 mm).

      What is the part number for a 96 pole chassis for iC60 C/B's for the MB switchboards?

      The part number for a 96 pole chassis for iC60 C/B's  for the MB switchboards is - C325963

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=C325963
       

      Can I use two different strings of solar panels on my MPPT80-600 charge controller and what would happen if I do?

      It is never a good idea to mix and match solar panels because the MPPT80 only has a single power tracker, so the MPPT algorithm continuously adjusts the operating points in an attempt to find the maximum power point of the array, which means the unit is going to use the sum of both strings and will derate the value of the bigger string. 

      Where can I get a copy of the Profibus manual for the Altivar Process Drives?

      Issue:
      Where can I get a copy of the Profibus manual for the Altivar Process Drives? 

      Product Line:
      Altivar Process Drives

      Environment:
      All serial numbers for Altivar Process Drives (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

      Cause:
      N/A

      Resolution:
      Altivar 600
      https://www.schneider-electric.com/en/download/document/EAV64329/

      Altivar 900
      https://www.schneider-electric.com/en/download/document/NHA80943/





       

      NetBotz 200 series | Description of RS, MM, & THM

      Issue:
      What does RS, MM, & THM mean within an event or alert on a NetBotz 200 Series?

      Product Line:
      NetBotz 200 Series (200 & 250)

      Environment:
      NetBotz 200 Series (all versions)

      Cause
      Certain aspects of the NetBotz 200 series web interface, logs, and alerts may contain acronyms for sensors and modules.

      Resolution:

      RS = Remote Sensor
      MM = Main Module
      THM = Temp/Humidity Expansion Module

      Application Services Host does not Connect to Citect Data Platform

      Issue
      In Application Configuration utility > Application Services Host > Citect Data Platform, the user tries to test Citect credentials, but gets the following error even when Runtime is running:


                
                      Citect connection unavailable.
                      Note: Citect runtime must be running to perform this test.



      Product Line
      PowerSCADA Expert 8.2 (PSE 8.2)

      Environment
      Application Configuration Utility

      Cause
      CtAPI is unavailable

      Resolution
      Adding the following parameter to Citect.ini file resolved the problem:
      [CtAPI] Remote=1

      What to do when StruxureOn app stops working

      Uninstall and reinstall the StruxureOn app

      Issue
      My app stopped working

      Product Line
      StruxureOn

      Environment
      StruxureOn iPhone app
      StruxureOn Android app

      Resolution
       
       

      Try this

      1. Force the app to close.
      2. Uninstall, then install the app again.
      3. Restart the phone and log in to the app.
       
       
      SEE ALSO

      PME Software does not appear in the list of programs under Control Panel

      Issue
      PME Software does not appear in the list of programs under Control Panel

      Product Line
      PME8.x

      PSE8.2

      Environment
      PME 8.x

      PSE8.x

      Cause
      There maybe instance where one needs to trouble shoot and possibly uninstall PME, but the program does not appear in the list of programs to uninstall or modify.


      Resolution
      Check if this system has PSE8.x with Advanced Reporting Module.  If you see the Advanced Reporting Module, then that corresponds to the PME software.  PSE with Advanced Reporting Module is a bundle package that incorporates a Power Scada system with PME software.  The PME software that you normally see such as Management Console, Designer is under the name of Advanced Reporting Module.



       
      Show More