grid & cover 2g arch

Switch Grid Plate and Cover, 2 Gang, Architrave

Catalogue Number: C2032
grid & cover 2g arch
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Classic Series C2000
Product brand
Clipsal
Number of gangs
2 gangs
Product destination
switch
Fixing mode
by screws
Material
plastic
Marking
without marking
Surface finish
glossy
Mounting position
vertical
Sustainable offer status
Green Premium product
REACh Regulation
Reference contains Substances of Very High Concern above the threshold
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP120506EN

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Product Environmental

  • Corporate Marketing

Frequently Asked Questions

hide show

What is the part number for the cover of the C2032 white

  C2032C-WE

Do you have a weatherproof cover that can be used with a C2032 plate?

Yes, the part name is 223H-WE.

 

What is the part number for a C2030 cover?

The part number for a C2030 cover is a C2001.

What is the part numbers for the covers only to suit C2000 1 gang and 2 gang switches ?

The part numbers are 1 gang - C2031C & 2 gang it is C2032C

Is there a blank architrave switch plate?

Unfortunately we do not do a blank architrave. You can create one using the 30P and a C2031.
 

What is the part number for a cover for a 3 gang switch in the Classic range , C2033?

The part number for a cover for a 3 gang switch in the Classic range , C2033 is - C2033C

 

What is the part number for a mounting block for the Classic 1 gang architrave switch , C2030?

The part number for a mounting block for the Classic 1 gang architrave switch , C2030 is - C2001C

For further information , visit link below;-
https://www.clipsal.com/Trade/search-results?q=C2001C
 

For the 15725 programmable timer what is the battery that fits into it?

CR2032 battery

Can I get a cover for C2033 architrave switch?


Yes, there are covers available for the 3 gang architrave switches. The part number is C2003C.

Some of the key features are:
  • Identification cover
  • For architrave flush switch
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2003C


 

Will changing the cover on the C2032V66 affect the IP rating ?

Changing the Cover ( C2032C ) does not affect IP rating as long as mechs not changed

For more information regarding this product please visit the Clipsal web site on the link provided

https://www.clipsal.com/Trade/search-results?q=c2032v66

What is the part number of the mounting block to suit C2030, Classic C2000 series 1 gang architrave switch?

70/1 is the part number of the mounting block to suit C2030.

Key Features

  • Moulded surface mounting blocks
  • With metal inserts
  • impact resistant
  • Mounting direction: Horizontal and vertical
  • Cable entry: Straight
  • To suits 1 gang architrave switches
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=70/1

What would be the part number for a brushed aluminium cover to suit a C2030-WE?

C2001C Switch Plate Cover, 1 Gang, Architrave
The first thing you'll notice about the C2000 classic series is the cover that comes in a choice of superb metal finishes and classic coloured plastic mouldings. This cover not only looks attractive, it also hides all mounting holes, and is easily removed to enable you to paint right up to the edge of the gridplate without having to worry about marking the cover. When decorating is complete, the cover is simply re placed for a perfect finish As C2000 classic series covers and gridplates can be mixed and matched, you can produce many combinations to match the particular decor theme you want to create
Please see below link for full colour selection and complete range.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2001C

wants ba cover for c2015

Code = C2015C-BA

​Is there an alternative C-Bus Switch for C5032NL-WE?

Yes, one off C2032VH + one off 5031NMML + one off 5031NMS

Is there a 32/32 version of the 56E1 available?

No. There is only a 56E1/20/20 or 56E1/25/25 available.

Is there a C2015 in 15A with extra switch?

Yes the part number for a C2015/15X.

What is the IP rating of C2025, C2000 series double outlet?

Unfortunately, C2025 does not have an IP rating.
For further information, on C2025 please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025

What can cause Err1 on ATV212 or ATV21 drive?

Product Line:
ATV212
ATV21

Environment:
All environments

Cause:
Setting the Refrences to the same numer

Resolution:
This is a Speed Reference Fault.  It indicates an incorrect setting in F201, F202, F203, F204 OR F210, F211, F212, F213.

Verify these parameters, and set them properly.
Default settings are:
F201 = 0%
F202 = 0Hz
F203 = 100%
F204 = 50/60Hz

F2010 = 0%
F2011 = 0Hz
F2012 = 100%
F2013 = 50/60Hz
 

What are the part numbers for Brushed Aluminium covers for the 1/2/3 gang architrave switches in the C2000 series?

The part numbers would be  C2001C-BA for single gang, C2002C-BA for double gang and C2003C-BA for triple.
These also come in a labelled version.

For more information, visit the website at https://www.clipsal.com/Trade/search-results?q=c2001c and click on the link to view a brochure.

What is the part number for a brushed aluminium cover for a SC2030 architrave switch?

The part number is SC2001C.
Though Slimline products are no longer available. We suggest the Iconic range as replacement, though if the same style is preferred the Classic C2000 is the same but not as slim.
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=SC2001C

 
 

What is part no for cover to suit C2025 ?

Part no C2025C will fit C2025

Is there a mounting block available for a C2033?

No unfortunately we do not offer mounting blocks for this switch as it is designed to be mounted on the door frame.

Does CAD32 come with Cat 3 certification?

No it does not.
Please refer the below link
https://www.dguv.de/ifa/Praxishilfen/Software/SISTEMA/index-2.jsp

What is the part number for a C2015 with 2 USBC?

The part number is C2015USB2C.

Can i get a brushed aluminium cover plate for a C2032A?

Yes,you can get a brushed aluminium cover plate for a 2 gang architrave switch. The part number is C2002C-BA.

What is the part number for a mounting block to suit a C2033A?

Unfortunately there is no mounting block for this product.

What will make up a double pole/double throw switch with a 24V Neon indicator in a plate

 Part codes you need  30MD2 + 30N24 + C2032VH

What reference do I add to the CAD32 or CAD50 to sepcify the coil voltage?

Add one of the codes listed in bold below to the end of the code. For example a 24V AC CAD32 would be CAD32B7

AC | 24V = B7 | 110V = F7 | 240V = U7 | 415V = N7
DC | 24V = BD

What is the part number for a C2025 with built in surge protection?

The part number for a C2025 with built in surge protection is C2025SF

 

What is the part number for a cleaners outlet and a C2015 with a round earth pin with identification label?

The part number for the cleaners outlet is a ML2015C.

A round earth pin single outlet in classic series with an identification window has the part number C2015LI.

For further information please visit https://www.clipsal.com

Are you able to get a C2025 in Arctic Silver, eg:C2025-3A.

These are unavailable at this time.
The Arctic Silver ( 3A ) was initilally released for the Slimline SC2000 series as they do not have full metal ( stainless steel ) covers in the SC2000 range
The closest would be a C2025 in soft grey with a C2025 cover in Brushed Aluminium or Stainless steel.
Please see following catalogue for complete range of colours and tech data.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025

Is there a black cover plate available to suit C2025 Twin Horizontal Mount Sockets in the C2000 Series?

Yes, the part code is C2025C-BK. The C2025C-BK are indent so we do not stock them, we will purchase them to order.

What is the part number for a cover plate for the SC2034?

The part number for a cover plate for the SC2034 is - SC2034C

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=SC2034C
 

​Is there an alternative C-Bus Switch for SL5032NL-WE?

No alternative with the same style look, but it can be replaced with a different style look with the same functionality switch.
  1. It can be replaced with Classic C2000 Series Grid Plate and 30 Mech switches, one off C2032VH + one off 5031NMML + one off 5031NMS
  2. It can be replaced with Slimline SC2000 Series Grid Plate and 30 Mech switches, one off SC2032VH + one off 5031NMML + one off 5031NMS

What is the part number for a cover , GOLD , for the Classic range double GPO , C2025 ?

The part number for a cover , GOLD , for the Classic range double GPO , C2025 is - C2025C-GD

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=C2025C-GD

What is the GM cover to suit C2025

 This is available in the new style only - part code C2025VC2-GM

What is part number for C2000 series 5 gang cover?

The part number for C2000 series 5 gang cover is a C2035C.

What is part number for 2 gang C2000 series vertical cover?

The part number for 2 gang C2000 series vertical cover is C2025VC.

Is cut out for Modena/Strato same as C2000?

Yes, same dimensions as C2000 series.

What is the part number for a Brass cover for the classic range 2 gang switch - C2032VA?

The part number for a Brass cover for the classic range 2 gang switch - C2032VA is - C2032C-BS

For further information visit link below:-
https://www.clipsal.com/Trade/search-results?q=C2032C-BS
User-added image

'Floppy disk failure' error is returned when starting the 174CEV20040 Mobus Plus to Ethernet bridge.

Goals and Symptoms

'Floppy disk(s) failed (40)' error is returned when starting the '174CEV20040' Mobus Plus to Ethernet bridge.

Facts and Changes

'174CEV20040' Mobus Plus to Ethernet bridge.

Causes and Fixes

The following error message is displayed on monitor that is connected to the '174VEV20040 Mobus


  • Plus to Ethernet Bridge' after it is turned on.

    Floppy disk(s) failed (40)
    CMOS checksum error - Defaults loaded.
    Warning! CPU has changed
    Please Enter CPU Speed CMOS Setup and Remember to Save Before Exit!

    The message will occur if the battery on the motherboard is fails. When the battery fails, the
    CMOS settings for the BIOS is lost and the motherboard reverts back to the factory default settings.

    Note: 1. This problem will only be noticeable after a power failure.
    2. To prevent this problem from occurring, it is recommended that the battery should be
    replaced every 3 years.

    The following steps can be used to resolve the problem.
  • Obtain a standard replacement battery ('Maxell CR2032 3 volt' or equivalent)
  • Ensure that you are properly grounded using an anti-static strap.
  • Remove the cover by unscrewing the four (4) screws.
  • Unscrew and remove the retaining screw from the metal bracket that is holding the Modbus Plus
Adapter card to the metal case.
  • Remove the Modbus Plus Adapter card.
  • Press down on the battery holder clip to release the battery.
  • Remove the old battery and replace it with the new one.
  • Insert the Modbus Plus Adapter card back into the same slot that it was in.
  • Screw the retaining screw back onto the metal bracket to hold Modbus Plus Adapter card
to the metal case.
  • Place the front cover back onto the metal case.
  • Screw the four (4) cover retaining screws back on.
  • Plug in the power supply, VGA monitor and keyboard.
  • Turn on the bridge
  • Press the 'Del' key to go into the BIOS setup.
  • Select the option named 'Standard CMOS Features'.
  • Hit the 'Enter' key.
  • Scroll down to the option named 'Drive A' using the down arrow key.
  • Hit the 'Enter' key.
  • Select 'None' in the 'Drive A' pop-up window using the up or down arrow keys.
  • Hit the 'Enter' key to accept the changes.
  • Hit the 'Esc' key to return to the main menu.
  • Hit the 'F10' key to save the changes and exit the setup.
  • Type 'y' to answer the question on the window that appears and shows the statement:
' Save to CMOS and EXIT (Y/N) ?'.
  • Hit the 'Enter' key.
  • Power cycle the Ethernet bridge.

Legacy KB System (APS) Data: RESL201982 V1.0, Originally authored by AlCh on 04/15/2010, Last Edited by AlCh on 04/15/2010
Related ranges: ConneXium - Ethernet

Is the C2025 available with a Stainless Steel facia?

Yes, the part number is C2025-SS.
For more information, please visit the link:https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025

Is C2025 available in Blue colour?

Yes. C2025-DB is a Classic double outlet, 250V,10A, in Dark Blue.
For further information, please refer to the below link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025

Do you have a double powerpoint in the Classic Series C2025 with neons on the switches?

Yes the part number is C2025DN. However it is double pole and has shutters. Alternatively we have a C2025N which has the Neon's next to the switch.

What is the minimum version of firmware required for the CM4000T to enable Flicker monitoring?

Issue
Minimum firmware required for flicker monitoring on the CM4000T

Product Line
CM4000T

Environment
Firmware

Resolution
It is necessary to have CM4000T firmware version 12.32 or later AND CVMT firmware 11.00 or later to enable Flicker monitoring.

What is the part number for a C2025 that is white with red dollies?

The part number for a C2025 that is white with red dollies is C2025RDL-WE.

Some of the key features are:
  • Red Dollies
  • Backed off terminal screws
  • Terminals suits 4 x 2.5 sq mm cables
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025RDL
 

Do you have a C2025 with a USB charger fitted?

Yes, we do have a C2025 with a USB charger fitted. The part number is C2025USBC.

Some of the key features are:
  • Single 30USBCM in a white twin power outlet
  • Smart 30USBCM USB charger optimizes charging time and current through: BC1.2 Standard Compliance and Cable compensation
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025USBC
 

What is the part number for the C2025 with safety shutters?

The part number for the C2025 with safety shutters is C2025S.

Some of the key features are:
  • Safety shutter
  • Backed off terminal screws
  • Terminals suits 4 x 2.5 sq mm cables
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2025S

 

Setting up a Write_VAR function block in a M340 to write to SDOs in a CAN device.

Goals and Symptoms

M340, CANopen, Write_Var

Causes and Fixes


First your project Configuration and double click on the CAN port to configure it



Configure the CAN port as needed for your application and notice the Channel # of the CAN port (Channel 2)
Note: The Inputs & Outputs configured here are for PDOs not SDOs.



Next open the CANopen Network from the Configuration. Double click on the Node to add a CAN device.



From the available list chose the CAN device you will be using and press OK.
For this example we are using a Altivar 71 drive.



A picture of the device will appear on the network. Double click in the Node box to adjust the Node ID of the device.
Then double click on the device for its configuration.



Configure the CAN Device as needed.
Note: PDOs are memory mapped directly to memory locations within the M340 SDOs are not.



Next open the Project Settings and configure them so that you can directly address arrays in your program.
This step is optional however if you do not do this you will need to declare variables as array's in you program.



Next open you program section and add a ADDM block (for addressing the CAN device) and a
Read_Var block.

The ADDM block for CAN has an input syntax of r.m.c.e (rack.module.channel.equipment) and is
entered as a string so a ' is needed before and after the string. The OUT pin is connected directly to the
ADR pin of the Read_Var.

The remaining parameters of the WRITE_VAR are configured as follow:

OBJ (object type we are reading, string input)
NUM (location in the CAN device we are reading from. Subindex_index for CAN)
NB (length of read in words)
EMIS (location array in the M340 where the information to be written is stored)
GEST (Array of 4 INTs used for the Write Manager Exchange)

In this Example we are writing a value from %MW110 of the M340 to the ACC Acceleration
at Subindex 0002 (hex) and Index 2032 (hex) in the Altivar drive.

Before you can download this to you PLC there is one additional step required.
For CANopen writes to SDOs from a Write_Var block a timeout value and transmission length
need to be configured in the Write Manager Exchange array.

Open the Variable Declaration editor declare variables for the 4 INTs in the Write Manager Exchange array.
The third and fourth INTs are for the timeout value (in tenths of a second) and the transmission length (in Bytes).

In our example we are writing 1 word so the length is 2 bytes.



Finally Build/Download your project and Run the PLC.


Is the CAD32BD Force guided?? Are the contacts mechanically linked?

Issue:
Like to know if CAD32BD is Force guided? Are the contacts mechanically linked? 

Product Line:
Relays and Timers

Environment:
North American Products
                                  
Resolution:                                                                 
The CAD32 relays are force guided, and the contacts are mechanically linked.
 
Show More