Max 4 Strip Connectors, 20A, 12 Terminal, Double Entry, 2 Way, Platform Bakelite

Max 4 Strip Connectors, 20A, 12 Terminal, Double Entry, 2 Way, Platform Bakelite

Max 4 Strip Connectors, 20A, 12 Terminal, Double Entry, 2 Way, Platform Bakelite

Item Number: BP7

Retail
$115.87
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

Blue Point

Physical

[In] rated current

20 A

Connector type

  • 1 screw terminals
  • 2 screw terminals
    • Number of poles

      12

      Mounting support

      panel

      Width

      25 mm grid pattern:

      Length

      136 mm

      Ambient air temperature for operation

      190 °C

      EU RoHS Directive

      Compliant

      Mercury free

      Yes

      RoHS exemption information

      Yes

      China RoHS Regulation

      Product out of China RoHS scope. Substance declaration for your information

      Material

      Material

      bakelite: insulation

      Others

      Distance between centers

      hole: 10.6 mm

      Cable cross section

      6-6 mm² fine stranded without cable end sleeve

      Minimum mounting height

      17 mm

      Unit Type of Package 1

      PCE

      Number of Units in Package 1

      1

      Package 1 Weight

      66.2 g

      Package 1 Height

      17 mm

      Package 1 width

      25 mm

      Package 1 Length

      139 mm
      Show all specifications

      Frequently Asked Questions

      hide show

      What is a bPF fault on the ATS22 soft starter?

      Issue:
      What is a bPF fault on the ATS22 soft starter?

      Product Line:
      Altistart ATS22

      Environment:
      All

      Cause:
      Bypass contactor detected fault

      Resolution:
      Check for a welded bypass contactor or shorted SCR.
      If you find a shorted SCR or bypass contactor, you will need to replace the soft starter.
      Reference the manual BBV51330 of ATS22 installation guide.

      What is the part number for a BPA sign in the Medilec range?

       The part number for a BPA sign in the Medilec range is SIGN/BPA.

      Some of the key features are:

      • Made from sturdy laminex
      • Adhesive on each corner for easy installation
      • Supplied with “test and date” stickers

       

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=SIGN/BPA

       

      Can BPH motors be used with the Lexiium 32 Servo drives?

      Yes, the BPH motors are compatible with Lexium 32 servo drives. They are to be characterized as third party motors.  If using a BPH motor with resolver, you will need to use a resolver option card P/N : VW3 M3 401. If using a BPH motor with encoder feedback, you will need to use an encoder option card.VW3 M3 403 (for hiperface encoder) along with a Lexum 32 modular drive (32M). The third party motor commissioning tool within SoMove helps calculate the offset to commutate the motor.

      MHDA1056N00 servo drive replacement

      Question:
      Replacement for the MHDA1056N00 drive

      Product Line:
      MHDA

      Resolution:
      The MHDA1056N00 servo drive is obsolete.
      The closest match is the LXM32MC10N4 (11kW instead of 14kW)
      The BPH motor will also have to be replaced.

      Looking for servo motor BPH190AK5MA2CA1

      Issue:
      Looking for servo motor BPH190AK5MA2CA1

      Product:
      Lexium BPH motors

      Resolution:
      This family of motors is obsolete. 
      The best option is to contact our service department at:
      Toll Free: +800-468-5342 ext. Opt #2
      Fax: +978-975-9425, Attention Dave D.
      Email: service.sales@schneider-electric.com

      Download links for Vijeo Designer V6.2 SP7

      Issue:
      Where can we find the download links for Vijeo Designer V6.2 SP7?

      Product Line:
      Vijeo Designer V6.2 (all hotfixes and service pack revisions less than SP7)

      Resolution:
      Please find the download links for Vijeo Designer V6.2 SP7 below


      (Required updates)
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7.exe


      (Optional updates)
      Updates Manuals and Help menus
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Docs_Package.exe

      Used on iPCs / PCs that are used as HMIs (ie. not the development environment)
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Runtime_for_Windows.exe

      Used on PCs where you need to connect to your HMI remotely via Web Gate
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Web_Gate_Client_Files_6.2_SP7.exe

      Release Notes
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Release_Notes/Vijeo_Designer_6.2_SP7_ReleaseNotes.htm

      What is the IP protection class for the BPH motor power and feedback cables?

      The only available IP protection for the power and feedback cables is IP 67.


      Legacy KB System (APS) Data: RESL182113 V1.0, Originally authored by TVe on 02/13/2007, Last Edited by TVe on 02/13/2007
      Related ranges: Lexium 17D

      What does BP designate at the end of a 9013F part number?

      Issue:
      What does the form BP mean at the end of a pressure switch part number

      Product Line:
      All Schneider Electric products

      Environment:
      Products sold and used in the United States

      Cause: 
      Customer needs to know what BP stands for at the end of a class 9013 part number.
       
      Resolution:
      The BP at the end of part numbers such as 9013FSG2J20BP calls out for a blister pack, this will come in plastic to hang on a display.

      Keywords:
      9013, 9013 type F, type G 9013F, 9013G, blister pack, form BP, BP, bulk pack

      How to perform MSET on a BPH motor using Lexium 17/15 Servo Drive?



      Issue:  Although the BPH motors that are used with the Lexium 17 and 15 range of Servo drives are factory MSET, occasionally there may be a need to MSET this in the field due to commutation error being reported. 


      Product Line: Lexium BPH


      Environment:


      Cause: Due to an incorrect offset value set in the drive, the drive may report a F25, commutation error.


      Resolution: This resolution discusses the MSET procedure for a BPH motor with a Lexium 17/15 series drive.

       
      Proper commutation and position feedback are required to interface a particular servo drive and motor combination. When using Schneider Electric BPH motors and Lexium drives, this setup (or “characterization”) process has been completed and verified for the user at the factory. Occasionally there may be a need to MSET the BPH motor and this is detailed in this procedure.
       
      Perform the following steps, as described, and in the order presented, to complete the MSET procedure. 
       
      1.    Disconnect the Motor from the Mechanical Load
      2.    Electrical Connections
      A.   Verify that the required electrical connections for drive power, logic power, motor power and resolver are as described in the Lexium drive user manual.
      B.   Apply 24VDC logic and AC input power to confirm proper drive startup sequence and self-checks.
       
       Follow this MSET procedure only if the drive firmware is ver 5.51 and above.
       
       Connect to the drive using Hyperterm…
       
      1. Type OPMODE followed by Enter – note down the Opmode (xx) the drive is set to.
       
      1. Type OPMODE 2 followed by Enter – switch to digital torque mode
           C.     Type 'EN' followed by Enter.

           D.     Type "Zero" followed by ENTER - Motor shaft will jump to nearest pole. MPHASE value is automatically set.
       
        
      1. Type SAVE
       
      1. Type OPMODE xx followed by enter ( where xx is the default value that was originally set for the application.)
       
           G.    Type COLDSTART (the drive will reboot)
      This completes the MSET procedure.

      Where can I download Vijeo Designer v6.2 Service Pack 7?

      Issue
      Where are the download links for Vijeo Designer v6.2 Service Pack 7?

      Product Line
      Vijeo Designer v6.2

      Environment
      Magelis HMI Configuration Software for Windows

      Resolution
      Vijeo Designer V6.2 SP7 download links:

      1) Release Notes HTML page for the Service Pack:
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Release_Notes/Vijeo_Designer_6.2_SP7_ReleaseNotes.htm

      2) Just the patch to install on top of the existing Vijeo Designer v6.2 installed on your PC/laptop:
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7.exe

      3) Help files update to your Vijeo Designer v6.2 (Vijeo Designer HTML help files and PDF manuals):
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Docs_Package.exe

      4) iPC/Standard PC Runtime if you need to have an iPC/Standard PC running as an HMI by itself:
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Runtime_for_Windows.exe

      5) Data Manager for retrieving Logging/Recipe data from an HMI (this is installed on your laptop/PC on top of your existing Vijeo Designer v6.2):
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Vijeo_Designer_6.2_SP7_Data-Manager.exe

      6) Web Gate Client Files (this is for if you are connecting to the HMI and want to mirror the screen on a remote PC's browser):
      https://www.update.schneider-electric.com/download/HMI/VijeoDesigner/Web_Gate_Client_Files_6.2_SP7.exe
       

      What is the replacement for the XBTGT7340?

      Issue:
      What is the replacement for the XBTGT7340?

      Product Line:
      Magelis HMI, XBTGT7000 series

      Resolution:
      The replacement for the XBTGT7340 is the:

      HMIG3U + HMIDT732 display (if video playback is not needed)
      HMIG5U2 + HMIDT732 display (if video playback is needed)

      Vijeo Designer V6.2 SP3.1 or greater is required for the HMIG3U / HMIG5U
      Vijeo Designer V6.2 SP7 or greater is required for the HMIG5U2

      What will cause the ATV212 drive inside of the S-flex not to power up when you switch the AFC off bypass switch to AFC mode?

      Issue:
      What will cause the ATV212 drive inside of the S-flex not to power up when you switch the AFC off bypass switch to AFC mode?

      Product Line:
      Altivar ATV212 S-flex enclosed with bypass option and B07 mod

      Environment:
      All 

      Cause:
      Line contactor is not pulliing in to power up the variable speed drive. because the OLR was tripped. 

      Resolution:
      1. Check to see if the red power LED is powered on the outside of the enclosure.  If this red power LED is on, then we know the CPT and fuses are all good.
      2. Check to see if the Line contactor is pulled in.  If the line contactor is not pulled in, check the control circuit to see what might be not allowing the contactor to pull in. 
      3. Check to see if the bypass circuit works by puttiing the AFC off bypass switch in bypass mode.
      4. If the bypass contactor is not pulling in, and the line contactor is not pulling in, check to see if the OLR has tripped and needs to be reset.
      Show More