ATV312 M2  for motor power 0,37 kW

Altivar 312 Variable Speed Drive, 0.18kW, 0.6kVA, 24W, 200..240V, 1 Phase Supply

Catalogue Number: ATV312H018M2
ATV312 M2  for motor power 0,37 kW
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
Altivar 312
Product or component type
variable speed drive
Product destination
asynchronous motors
Product specific application
simple machine
Assembly style
with heat sink
Component name
ATV312
Motor power kW
0.18 kW
Motor power hp
0.25 hp
[Us] rated supply voltage
200...240 V - 15...10 %
Supply frequency
50...60 Hz - 5...5 %
Network number of phases
single phase
Line current
  • 3 A at 200 V, Isc = 5 kA
  • 2.5 A at 240 V
    • EMC filter
      integrated
      Apparent power
      0.6 kVA
      Maximum transient current
      2.3 A for 60 s
      Power dissipation in W
      24 W at nominal load
      Speed range
      1-50
      Asynchronous motor control profile
    • sensorless flux vector control with PWM type motor control signal
    • factory set : constant torque
      • Electrical connection
      • Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5-2.5 mm² AWG 14
      • L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5-2.5 mm² AWG 14
        • Supply
        • internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and short-circuit protection
        • internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA, protection type: overload and short-circuit protection
          • Communication port protocol
          • Modbus
          • CANopen
            • IP degree of protection
            • IP20 on upper part without cover plate
            • IP21 on connection terminals
            • IP31 on upper part
            • IP41 on upper part
              • Option card
              • communication card for CANopen daisy chain
              • communication card for DeviceNet
              • communication card for Fipio
              • communication card for Modbus TCP
              • communication card for Profibus DP
                • Supply voltage limits
                  170-264 V
                  Network frequency
                  47.5...63 Hz
                  Prospective line Isc
                  5 kA
                  Continuous output current
                  1.5 A at 4 kHz
                  Output frequency
                  0-500 kHz
                  Nominal switching frequency
                  4 kHz
                  Switching frequency
                  2...16 kHz adjustable
                  Transient overtorque
                  170-200 % of nominal motor torque
                  Braking torque
                • 150 % during 60 s with braking resistor
                • 100 % with braking resistor continuously
                • 150 % without braking resistor
                  • Regulation loop
                    frequency PI regulator
                    Motor slip compensation
                  • automatic whatever the load
                  • suppressable
                  • adjustable
                    • Output voltage
                      <= power supply voltage
                      Tightening torque
                    • Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6: 0.6-0.6 N.m
                    • L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 0.8-0.8 N.m
                      • Insulation
                        electrical between power and control
                        Analogue input number
                        3
                        Analogue input type
                      • AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance: 30000 Ohm
                      • AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm
                      • AI3 configurable current 0...20 mA, impedance: 250 Ohm
                        • Sampling duration
                        • AI1, AI2, AI3: 8 ms analog
                        • LI1...LI6: 4 ms discrete
                          • Response time
                          • AOV, AOC 8 ms for analog
                          • R1A, R1B, R1C, R2A, R2B 8 ms for discrete
                            • Linearity error
                              +/- 0.2 % for output
                              Analogue output number
                              1
                              Analogue output type
                            • AOC configurable current: 0...20 mA, impedance: 800 Ohm, resolution: 8 bits
                            • AOV configurable voltage: 0...10 V, impedance: 470 Ohm, resolution: 8 bits
                              • Discrete input logic
                              • logic input not wired (LI1...LI4), < 13 V (state 1)
                              • negative logic (source) (LI1...LI6), > 19 V (state 0)
                              • positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)
                                • Discrete output number
                                  2
                                  Discrete output type
                                • configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
                                • configurable relay logic: (R2A, R2B) NC - 100000 cycles
                                  • Minimum switching current
                                    R1-R2 10 mA at 5 V DC
                                    Maximum switching current
                                  • R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms
                                  • R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms
                                  • R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms
                                  • R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms
                                    • Discrete input number
                                      6
                                      Discrete input type
                                      (LI1...LI6) programmable at 24 V, 0-100 mA for PLC, impedance: 3500 Ohm
                                      Acceleration and deceleration ramps
                                    • linear adjustable separately from 0.1 to 999.9 s
                                    • S, U or customized
                                      • Braking to standstill
                                        by DC injection
                                        Protection type
                                      • input phase breaks: drive
                                      • line supply overvoltage and undervoltage safety circuits: drive
                                      • line supply phase loss safety function, for three phases supply: drive
                                      • motor phase breaks: drive
                                      • overcurrent between output phases and earth (on power up only): drive
                                      • overheating protection: drive
                                      • short-circuit between motor phases: drive
                                      • thermal protection: motor
                                        • Insulation resistance
                                          >= 500 mOhm 500 V DC for 1 minute
                                          Local signalling
                                        • 1 LED (red)drive voltage:
                                        • four 7-segment display unitsCANopen bus status:
                                          • Time constant
                                            5 ms for reference change
                                            Frequency resolution
                                          • analog input: 0.1...100 Hz
                                          • display unit: 0.1 Hz
                                            • Connector type
                                              1 RJ45 for Modbus/CANopen
                                              Physical interface
                                              RS485 multidrop serial link
                                              Transmission frame
                                              RTU
                                              Transmission rate
                                            • 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen
                                            • 4800, 9600 or 19200 bps for Modbus
                                              • Number of addresses
                                              • 1-127 for CANopen
                                              • 1-247 for Modbus
                                                • Number of drive
                                                • 127 for CANopen
                                                • 31 for Modbus
                                                  • Marking
                                                    CE
                                                    Operating position
                                                    vertical +/- 10 degree
                                                    Height
                                                    145 mm
                                                    Width
                                                    72 mm
                                                    Depth
                                                    132 mm
                                                    Net weight
                                                    1.5 kg
                                                    Dielectric strength
                                                  • 2040 V DC between earth and power terminals
                                                  • 2880 V AC between control and power terminals
                                                    • Electromagnetic compatibility
                                                    • 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
                                                    • electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
                                                    • electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
                                                    • radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
                                                      • Standards
                                                      • IEC 61800-3
                                                      • IEC 61800-5-1
                                                        • Product certifications
                                                        • DNV
                                                        • NOM
                                                        • CSA
                                                        • UL
                                                        • GOST
                                                        • C-Tick
                                                          • Pollution degree
                                                            2
                                                            Protective treatment
                                                            TC
                                                            Vibration resistance
                                                          • 1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6
                                                          • 1.5 mm (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
                                                            • Shock resistance
                                                              15 gn for 11 ms conforming to EN/IEC 60068-2-27
                                                              Relative humidity
                                                            • 5-95 % without condensation conforming to IEC 60068-2-3
                                                            • 5-95 % without dripping water conforming to IEC 60068-2-3
                                                              • Ambient air temperature for storage
                                                                -25-70 °C
                                                                Ambient air temperature for operation
                                                              • -10-50 °C without (with protective cover on top of the drive)
                                                              • -10-60 °C with derating factor (without protective cover on top of the drive)
                                                                • Operating altitude
                                                                • <= 1000 m without
                                                                • 1000...2000 m with current derating 1 % per 100 m
                                                                  • Sustainable offer status
                                                                    Green Premium product
                                                                    REACh Regulation
                                                                    Reference contains Substances of Very High Concern above the threshold
                                                                    EU RoHS Directive
                                                                    Pro-active compliance (Product out of EU RoHS legal scope)
                                                                    Mercury free
                                                                    Yes
                                                                    RoHS exemption information
                                                                    Yes
                                                                    China RoHS Regulation
                                                                    X
                                                                    Environmental Disclosure
                                                                    ENVPEP110706EN
                                                                    Circularity Profile
                                                                    ENVEOLI100203EN
                                                                    WEEE
                                                                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                                    California proposition 65
                                                                    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
                                                                    Warranty
                                                                    18 months

                                                                    Documents & downloads

                                                                    hide show
                                                                    Filter items
                                                                    • All

                                                                    • Product Brochures

                                                                    • CAD Files and Packs

                                                                    • Technical Data Catalogues

                                                                    • Catalog Page

                                                                    • Technical Leaflet

                                                                    • Installation Instruction

                                                                    • Product Environmental

                                                                    • Handout

                                                                    • End of Life Manual

                                                                    • Data Bulletin

                                                                    • Operating Manuals

                                                                    • System User Guide

                                                                    • Specification for Tender

                                                                    • Application Solutions

                                                                    • Certificates (MSDS)

                                                                    • Marine Certificate

                                                                    • White Paper

                                                                    • eTechPub

                                                                    • EDS Files

                                                                    • Software - Updates

                                                                    • Firmware - Released

                                                                    • Software - Released

                                                                    • DTM Files

                                                                    Frequently Asked Questions

                                                                    hide show

                                                                    Do we have CAD drawings for the ATV312 drives?

                                                                    Issue:
                                                                    Do we have CAD drawings for the ATV312 drives?

                                                                    Product Line:
                                                                    Altivar ATV312 and ATV31

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Cad drawings

                                                                    Resolution:
                                                                    Use the following link to the CAD Drawings Catalog.

                                                                    https://www.schneider-electric.us/sites/us/en/support/product-support-resources/3d-cad.page


                                                                    CTA-ID : 2061638

                                                                    Can the ATV312 be powered by an external 24V only?

                                                                    Issue:
                                                                     Powering the  ATV312 by an external 24V only

                                                                    Product Line:
                                                                     ATV312

                                                                    Environment:
                                                                     External 24v supply

                                                                    Cause:
                                                                    n/a
                                                                     
                                                                    Resolution:
                                                                    No, this drive must have line voltage applied.  The voltage must be within -15% to +10% of the rated line voltage. 

                                                                     

                                                                    What is the din rail mounting kit part number for the ATV312?

                                                                    Issue:
                                                                    What is the din rail mounting kit part number for the ATV312?

                                                                    Product Line:
                                                                    ATV312

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Desire to utilize din mounting kit option

                                                                    Resolution:
                                                                    The part numbers need to order the mounting kit for this drive are VW3A9804 and VW3A9805.

                                                                    VW3A9804 covers the following range of drives: ATV312....
                                                                    018M2, H037M2, H055M2, H075M2, H018M3, H037M3, H055M3, H075M3

                                                                    VW3A9805 covers the following range of drives: ATV312....
                                                                    HU11M2, HU15M2, HU11M3, HU15M3, HU22M3, H037N4, H055N4, H075N4, HU11N4, HU15N4, H075S6, HU15S6
                                                                    Note: The din rail mounting kits are only available for the above drives. 

                                                                    Note: Other drives not list above do not have a din rail kit.

                                                                    What is the part number for the remote keypad for the ATV31?

                                                                    Issue:   What is the part number for the remote keypad for the ATV31?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Remote keypad kit
                                                                     
                                                                    Resolution:   The Altivar 31 remote mount keypad kit is VW3A31101.
                                                                    The kit includes a keypad, mounting hardware and a 3 meter cable.


                                                                     

                                                                    Are the EMC filters for ATV31 drives UL or cUL listed?

                                                                    Issue:   Are the EMC filters for ATV31 drives UL or cUL listed?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   UL/CUL listing
                                                                     
                                                                    Resolution:   No. VW3A31401, VW3A31402, VW3A31403, VW3A31404, VW3A31405, VW3A31406, VW3A31407, VW3A31408 and VW3A31409 are not UL or CUL listed.

                                                                     

                                                                    What is the part number for the conduit entry kit for the ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6?

                                                                    Issue:   What is the part number for the conduit entry kit for the ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6?
                                                                     
                                                                    Product Line:   ATV312
                                                                     
                                                                    Environment:   ATV312HU11M2, ATV312HU15M2, ATV312HU22M3, ATV312H037N4, ATV312H055N4, ATV312H075N4, ATV312HU11N4, ATV312HU15N4, ATV312H075S6 or ATV312HU15S6
                                                                     
                                                                    Cause:   Conduit entry kit
                                                                     
                                                                    Resolution:   
                                                                    VW3A31814


                                                                     

                                                                    Is there a password to protect parameters in the ATV31 drive?

                                                                    Issue:   Is there a password to protect parameters in the ATV31 drive?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Password
                                                                     
                                                                    Resolution:   Yes.
                                                                    In the SUP menu, the COd parameter can be used to enter a numerical code that restricts access to adjustment parameters in the drive.  Only the display parameters are accessible, with only a temporary choice of the parameter displayed.

                                                                     

                                                                    How is the ATV31 set up to operate by remote keypad?

                                                                    Issue:   How is the ATV31 set up to operate by remote keypad?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Remote keypad operation
                                                                     
                                                                    Resolution:   With the VW3A31101 remote keypad kit installed, go to menu CtL and set parameter LCC to YES.
                                                                    NOTE:  LCC can only be accessed if the drive controller is equipped with a remote keypad display, and if LAC = L1 or L2.
                                                                    This function enables control of the drive with the STOP/RESET, RUN, and FWD/REV buttons on the remote keypad display.
                                                                    The speed reference is given by parameter LFr in the SEt- menu.
                                                                    Only the freewheel stop, fast stop, and DC injection stop commands remain active on the terminal block.
                                                                    If the remote keypad display is not connected, the drive controller will lock on an SLF fault.

                                                                     

                                                                    Does it matter where the pull up / pull down resistors are located within the ATV31 multiple drive network?

                                                                    Issue:   Does it matter where the pull up / pull down resistors are located within the ATV31 multiple drive network?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Terminating resistor
                                                                     
                                                                    Resolution:   Not really.
                                                                      
                                                                    The ATV31 does not have internal pull up / down resistors for the rs-485 communications. Therefore, if it is used on a network with PLC that also does not have pull up-down resisitors for the RS485 resistors must be added at one of the devices.
                                                                    At one drive add:
                                                                    10k resistor between +10 (RJ45 pin 7) and D_B (Communication +, RJ45 pin 4)
                                                                    10k resistor between D_B and COM (RJ45 pin 8)
                                                                    4.7k resistor between COM and D_A (RJ57 pin 5)


                                                                     

                                                                    What is the part number of the replacement fan for an ATV16, ATV18, ATV28, ATV31, ATV11?

                                                                    Issue:
                                                                    What is the part number of the replacement fan for an ATV16, ATV18, ATV28, ATV31, ATV11?
                                                                     
                                                                    Product Line:
                                                                    ATV16 ATV18 ATV28 ATV31 ATV11
                                                                     
                                                                    Environment:
                                                                    All
                                                                     
                                                                    Cause:
                                                                    Replacement parts
                                                                     
                                                                    Resolution: 
                                                                    Field replacement parts are not offered for these drives. 
                                                                    The drive may be sent in for depot analysis, repair and/or exchange within the warranty period.
                                                                    Contact any SquareD distributor for assistance.
                                                                    Distributors can contact customer service for RMA.


                                                                     

                                                                    Can Class T fuses be used with Altivar 31 drives? The manual only references Class CC or J.

                                                                    The ATV31 units were tested with the Class J fuses however the 600V version of the Class T fuses have equivalent ratings. So can use the 600V Class T fuses but not the 300V Class T fuses.

                                                                    Why does RDY flash on the ATV31?

                                                                    Issue:   
                                                                    Why does RDY flash on the ATV31?
                                                                     
                                                                    Product Line:   
                                                                    ATV31
                                                                     
                                                                    Environment:  
                                                                    All serial numbers
                                                                     
                                                                    Cause:  
                                                                    Customer said drive was flashing RDY.
                                                                     
                                                                    Resolution:   
                                                                    Flashing display normally indicated current limit mode. However, if this is occurring in the ready mode, it is likely due to incorrect motor parameter settings.
                                                                    Specifically, it could be that the COS (motor power factor) is set to 1.
                                                                    OR
                                                                    Check the +10 and +24 VDC power supplies. It could be that they are being pulled down.


                                                                     

                                                                    Do any of the ATV31 drives Not have an internal fan ?

                                                                     

                                                                    Issue:   Do any of the ATV31 drives Not have an internal fan ?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  ATV31H018M2 & ATV31H018M2A & ATV31H018M3X & ATV31H018M3XA
                                                                    ATV31H037M2 & ATV31H037M2A & ATV31H037M3X & ATV31H037M3XA
                                                                    ATV31H055M2 & ATV31H055M2A & ATV31H055M3X & ATV31H055M3XA
                                                                    ATV31H075M2 & ATV31H075M2A & ATV31H075M3X & ATV31H075M3XA
                                                                     
                                                                    Cause:   No heatsink fan
                                                                     
                                                                    Resolution:   Yes, the following do not have a heatsink fan:
                                                                    ATV31H018M2 & ATV31H018M2A & ATV31H018M3X & ATV31H018M3XA
                                                                    ATV31H037M2 & ATV31H037M2A & ATV31H037M3X & ATV31H037M3XA
                                                                    ATV31H055M2 & ATV31H055M2A & ATV31H055M3X & ATV31H055M3XA
                                                                    ATV31H075M2 & ATV31H075M2A & ATV31H075M3X & ATV31H075M3XA

                                                                    What are the dimensions for the ATV31 keypad in the VW3A31101 remote mount kit?

                                                                    Issue:   What are the dimensions for the ATV31 keypad in the VW3A31101 remote mount kit?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  VW3A31101
                                                                     
                                                                    Cause:   Dimensions
                                                                     
                                                                    Resolution:   The keypad is 2.77(H) and 1.98(W) inches.
                                                                    The exterior dimensions for the mounting bracket is 4.19 (4 - 3/16) inches tall, 2.625 (2 - 5/8) inches wide


                                                                     

                                                                    Can the ATV31 be set up to operate with remote keypad command and still use an external speed pot to control the speed?

                                                                    Issue:   
                                                                    Can the ATV31 be set up to operate with remote keypad command and still use an external speed pot to control the speed?
                                                                     
                                                                    Product Line: 
                                                                     ATV31
                                                                     
                                                                    Environment:  
                                                                    All
                                                                     
                                                                    Cause:  
                                                                    N/A
                                                                     
                                                                    Resolution:  
                                                                     Yes. The drive can be set up to run by remote keypad to start and stop the unit while taking a speed reference from the Analog Input, AI1.
                                                                    This function can be set up in the CtL menu.  Set parameter LAC to L3.  Set Fr1 to AI1,  CHCF to SEP, and Cd1 to LCC.  

                                                                    See the Altivar 31 Adjustable Speed Drive Controllers Programming Manual, VVDED303042US, for details.

                                                                     

                                                                    What can cause the InF fault in the Altivar 31 and Altivar 312 drives?

                                                                    Issue:
                                                                    What can cause the InF fault in the Altivar 31 and ATV312 drives?

                                                                    Product Line:
                                                                    Altivar 31 and ATV312 drives

                                                                    Environment:
                                                                    All 

                                                                    Cause:
                                                                    Internal fault 

                                                                    Resolution:
                                                                    InF indicates an internal fault.  
                                                                    It can occur if there are loose connections inside the drive or if the drive is subjected to electromagnetic interference.  Check the line voltage to the drive.
                                                                    Also, check the voltages on the control terminals, +10 to COM and 24V to COM.  It has been observed that improper wiring of the inputs or external potentiometer can overload the internal power supplies of the drive. This may result in InF fault.
                                                                    Incorrect connections on the RJ45 ModBus/CANopen port can also cause this.  Verify wiring, particularly to pin 7 (10VDC supply for external keypad).



                                                                     

                                                                    ATV31 drive is set up to run with 2 preset speeds and will only run at 10Hz regardless of the programmed value for SP2 (ex. SP2=60Hz).

                                                                    Issue:   ATV31 drive is set up to run with 2 preset speeds and will only run at 10Hz regardless of the programmed value for SP2 (ex. SP2=60Hz).
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Preset speeds
                                                                     
                                                                    Resolution:   Verify that the logic input used for PS2 is not set to perform another function. For example, when ATV31 drive is configured for 3-wire control, LI4 will be set for JOG. The jog function will have priority.  If jog function is not required, JOG in the FUn menu needs to be set to nO.
                                                                    The functions of each logic input can be verified in the SUP menu. Go to sub-menu LIA. Scroll to the desired input (LI1A, LI2A. . . ) Enter to see to what the function of the input is assigned. Scroll up and down to see if there are additional functions assigned.

                                                                     

                                                                    What is the part number for the Ethernet / Modbus bridge adapter for the ATV31?

                                                                    Issue:   What is the part number for the Ethernet / Modbus bridge adapter for the ATV31?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Ethernet / Modbus bridge
                                                                     
                                                                    Resolution:   The part 174CEV30020 is obsolete.
                                                                    Use TSXETG100


                                                                     

                                                                    How is the ATV31 setup for AI3 input to be the primary speed reference?

                                                                    Issue:   How is the ATV31 setup for AI3 input to be the primary speed reference?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Speed reference
                                                                     
                                                                    Resolution:   In the CtL menu, set the Fr1 parameter to AI3.

                                                                     

                                                                    What is an ATV31****378?

                                                                    Issue:  
                                                                    What is an What is an ATV31****378?
                                                                     
                                                                    Product Line: 
                                                                    ATV31
                                                                     
                                                                    Environment:
                                                                    N/A

                                                                     
                                                                    Cause:   N/A
                                                                     
                                                                    Resolution:   
                                                                    This is a special drive for Buhler Company. The 378 suffix indicates that logic input LI6 can be used as a 24vdc pulsed speed reference. Would need to obtain a replacement from Buhler Company. May also be identified as S378 suffix.

                                                                    What is a good source of information for the ATV12?

                                                                    Issue:
                                                                    What is a good source of information for the ATV12?

                                                                    Product Line:
                                                                    Altivar 12

                                                                    Environment:
                                                                    All models and serial numbers

                                                                    Cause:
                                                                    Information is needed for installation and programming.

                                                                    Resolution:
                                                                    User manual is document number BBV28581.  This manual includes instructions for installing the drive, connecting the control wiring, programming and troubleshooting.
                                                                    https://www.schneider-electric.us/en/download/document/BBV28581/

                                                                    Want is the part number for the remote mount keypad for the ATV31?

                                                                    Issue:   Want is the part number for the remote mount keypad for the ATV31?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:   Remote keypad
                                                                     
                                                                    Resolution:   VW3A31101. This kit includes a remote keypad, remote mount hardware seal and screws for IP65 mounting on enclosure door and 3 meter cable fitted with 2 connectors.

                                                                     

                                                                    What are the specifications for ATV31 drive output relays?

                                                                    Issue:   What are the specifications for ATV31 drive output relays?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  All
                                                                     
                                                                    Cause:    Relay specs

                                                                    Resolution:   There are two relays in the drive.
                                                                    Relay R1 has three terminals to provide a Normally Open (NO) and a Normally Closed contact from a common.
                                                                    R1A is a N.O. contact.
                                                                    R1B is a N.C. contact.
                                                                    R1C is the common.
                                                                    R1 is a programmable relay.  When programmed as the factory default, drive fault relay, R1A is closed and R1B is open when the controller is powered and not faulted. Both contacts will change state when the drive faults.

                                                                    Relay R2 has two terminals to provide a NO contact, R2A & R2C.  This relay is also programmable.

                                                                    Electrical Characteristics are as follows:
                                                                    Min. switching capacity: 10 mA for 5 Vdc
                                                                    Max. switching capacity on a resistive load (power factor = 1 and L/R time constant = 0 ms): 5 A for 250 Vac and 30 Vdc
                                                                    Max. switching capacity on an inductive load (power factor = 0.4 and L/R time constant = 7 ms): 1.5 A for 250 Vac and 30 Vdc
                                                                    Sampling time: 8 ms
                                                                    Service life: 100,000 operations at maximum switching power;
                                                                                       1,000,000 operations at minimum switching power.

                                                                     

                                                                    How is the maximum speed changed in the ATV31 or ATV312 drive so that the motor can operate above 60Hz?

                                                                    Issue:   
                                                                    How is the maximum speed changed in the ATV31 or ATV312 drive so that the motor can operate above 60Hz?
                                                                     
                                                                    Product Line:   
                                                                    ATV31 ATV312
                                                                     
                                                                    Environment:  
                                                                    All
                                                                     
                                                                    Cause:  
                                                                    Changing high speed / max frequency
                                                                     
                                                                    Resolution:   
                                                                    Parameter HSP determines the maximum speed the drive can operate.  Parameter tFr determines the maximum value that HSP can be adjusted.  

                                                                    By default, tFr is set to 60Hz.  When changing the Motor Frequency - bFr this changes tFr to 72Hz.  

                                                                    To increase the maximum speed above 72Hz - Go to the drc menu and Set parameter tFr.  This can be adjusted up to 500Hz.  After saving the change, go to the SEt menu > HSP and adjust up to the desired speed.  

                                                                    If your motor is a specialty motor that is rated for a frequency other than 50Hz. or 60Hz. such as a 300Hz. rated spindle motor, change paramter FrS under the DRC menu to match the rated frequency of the motor.

                                                                     

                                                                    What input is designed for a bipolar -10v to +10v input on the ATV32 drives?

                                                                    Issue:
                                                                    What input is designed for a bipolar -10v to +10v input on the ATV32 drives?

                                                                    Product Line:
                                                                    Altivar ATV32

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    AI2 is default for -10v to +10v input.

                                                                    Resolution:
                                                                    IO menu AI2 set up

                                                                     Bipolar analog input 0 ± 10 V (maximum voltage ± 30 V)

                                                                    The + or - polarity of the voltage on AI2 affects the direction of the set point and therefore the direction of operation.

                                                                    • Impedance 30 kÙ
                                                                    • Resolution: 10 bits
                                                                    • Precision ±0.5% in 50/60 Hz for 25 °C, ±0.2% in 50/60 Hz for –10 to +60 °C at Äè = 60°C,
                                                                    • Linearity ± 0.2% (max. ± 0.5%), of max. value
                                                                    • Sampling time 2 ms

                                                                    Can the ATV31...A model be setup to use the integral speed pot dial for reference adjustment, but use the LI logic input for a run forward command?

                                                                    Issue:   Can the ATV31...A model be setup to use the integral speed pot dial for reference adjustment, but use the LI logic input for a run forward command?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  ATV31**A models
                                                                     
                                                                    Cause:   N/A
                                                                     
                                                                    Resolution:   Yes.  In the IO menu, set parameter tCC to 2C.  This assigns LI1 as run forward command.  In the CtL menu, set parameter Fr1 to AIP.

                                                                     

                                                                    When do the cooling fans on the ATV212 drives come on?

                                                                    Issue:
                                                                    When do the cooling fans on the ATV212 drives come on?

                                                                    Product Line:
                                                                    Altivar 212

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Fan control strategy

                                                                    Resolution:
                                                                    The fan starts when the drive is in RUN state.
                                                                    The fan stops after the STOP command (with a time delay in relation to the thermal state).

                                                                    What are the dimensions and weight for the ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X?

                                                                    Issue:   What are the dimensions and weight for the ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  ATV31HU11M2, ATV31HU15M2, ATV31HU22M3X, ATV31H037N4, ATV31H055N4, ATV31H075N4, ATV31HU11N4, ATV31HU15N4, ATV31H075S6X or ATV31HU15S6X
                                                                     
                                                                    Cause:   
                                                                     
                                                                    Resolution:   This is the size 6 and the dimensions are:
                                                                    Width = 4.13 inches 105 mm
                                                                    Height = 5.63 inches 143 mm
                                                                    Depth = 5.91 inches 150mm
                                                                    The weight is 2.92 lbs (1.35 kg)


                                                                     

                                                                    Can an ATV212 drive's programming be saved to the HMI keypad (VW3A1101) and transferred to another ATV212?

                                                                    Issue:
                                                                    Needs the ATV212 drive's programming be saved to the HMI keypad (VW3A1101) and transferred to another ATV212?

                                                                    Product Line:
                                                                    Altivar 212

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    N/A

                                                                    Resolution:
                                                                    No, the ATV212's programming cannot be saved to any of the keypads available.  

                                                                    Programming can be saved by any of three methods:
                                                                    - in the drive by setting parameter tYP = 7
                                                                    - in the Multiloader tool
                                                                    - by using SoMove software, downloading the ATV212 DTM File, and using the TCSMCNAM3M002P - SoMove cable

                                                                    Is it possible to power the 230Vac ATV61 drive from DC Bus?

                                                                    Issue:
                                                                    Is it possible to power the  ATV61 drive 230Vac from DC Bus?

                                                                    Product Line:
                                                                    Altivar 61 ATV61

                                                                    Environment:
                                                                    230Vac , All series

                                                                    Cause:
                                                                    None

                                                                    Resolution:
                                                                    A separate DC source (approx 325Vdc) can be connected to PA/+ and PC/-  to power up the 230 Vac drive. DC Bus fuses are recommended for short circuit protection. No external Precharge resistor is necessary because it is built-in to the drive.

                                                                    What is the part number for Nema 1 conduit kit for ATV312HU11M3 drive?

                                                                    Issue:
                                                                    What is the part number for Nema 1 conduit kit for ATV312HU11M3 drive? 

                                                                    Product Line:
                                                                    ATV312, Altivar 312

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    N/A

                                                                    Resolution:
                                                                    The part number for a Nema 1 conduit kit is VW3A31813.
                                                                     

                                                                    Are the ATV312 drives suited to be highpot tested?

                                                                    Issue:
                                                                    Are the ATV312 drives suited to be highpot tested?

                                                                    Product:
                                                                    ATV312

                                                                    Environment:
                                                                    All 

                                                                    Cause:
                                                                    None.

                                                                    Resolution:
                                                                    It is not recommended to High Pot test the VFDs. It may cause damage that will void the warranty.

                                                                    What is the replacement for the ATV312HU15S6?

                                                                    The closest replacement for the ATV312HU15S6 is ATV320U15S6C -
                                                                    https://www.schneider-electric.com/en/product/ATV320U15S6C/variable-speed-drive-atv320---1.5kw---600v---3phase---compact/

                                                                    It cannot be purchased in Australia because it is a High Rated Supply (Above 500V)

                                                                    The unit can be purchased globaly from one of our other countries, but cannot be used in Australia.
                                                                     

                                                                    What is the replacement for ATV31H055M2 VSD?

                                                                     The replacement for ATV31H055M2 is  ATV312H055M2

                                                                    ATV312H055M2 
                                                                    variable speed drive ATV312 - 0.55kW - 1.4kVA - 46W - 200..240 V- 1-phase supply

                                                                    For more information see;=https://www.schneider-electric.com.au/en/search/ATV312H055M2?category=product

                                                                    Why does ATV312 drive only shows Ref and Sup menus?

                                                                    Issue:
                                                                    Why does ATV312 drive only shows Ref and Sup menus?

                                                                    Product Line:
                                                                    ATV312 Drives

                                                                    Environment:
                                                                    All serial numbers for ATV312 Drives

                                                                    Cause:
                                                                    N/A

                                                                    Resolution:
                                                                    The drive may be locked.
                                                                    Go to SUP menu and then parameter COd
                                                                    If COd is set to ON the drive has been locked.

                                                                    To temporarily unlock the drive you have to change the COd parameter to the password and press ENT.
                                                                    This will unlock the drive until the power is cycled to the drive.

                                                                    To permanatly unlock the drive you must set the COd parameter to OFF after entering the password.
                                                                     

                                                                    What is the ambient temperature operating range of the ATV12 series drives?

                                                                    Issue:
                                                                    What is the ambient temperature operating range of the ATV12 series drives?

                                                                    Product Line:
                                                                    ATV12 series drives.

                                                                    Environment:
                                                                    All models, All serial numbers.

                                                                    Cause:
                                                                    N/A

                                                                    Resolution:

                                                                    Ambient Air Temperature**

                                                                    ATV12H018F1, ATV12H037F1
                                                                    ATV12H018M2...H075M2
                                                                    ATV12H018M3...H075M3
                                                                    ATV12P models
                                                                    Operation -10C to +40C without derating.  Up to +60C with derating.  Remove the blanking cover and de-rate at 2% per degree above 40C. 

                                                                    ATV12H075F1
                                                                    ATV12HU15M2, HU22M2
                                                                    ATV12HU15M3...HU40M3
                                                                    Operation -10C to +50C without derating.  Up to +60C with derating.  Remove the blanking cover and de-rate at 2% per degree above 50C. 

                                                                    Storage temperature for all units is -25C to +70C

                                                                    ** UL ratings are up to 40C only.  Higher temperature ratings listed above are for non-UL listed applications only.

                                                                    What should be checked if an Altivar 61 or 71 display is showing NLP?

                                                                    Issue:
                                                                    What should be checked if an Altivar 61 or 71 display is showing NLP?

                                                                    Product Line:
                                                                    ATV61/71 drives

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Drive displays 'NLP'

                                                                    Resolution:
                                                                    NLP indicates that no line power is present on the L1, L2 & L3 input terminals of the drive controller.

                                                                    Check voltage at the L1, L2 & L3 terminals.
                                                                    Check for open circuits on line contactors, circuit breakers, disconnect switches, or fuses.

                                                                    If NLP state does not change with correct voltage present on L1, L2, & L3, remove the control board and check for loose connections of ribbon cables inside the drive.
                                                                    WARNING: This step should be performed while the drive is powered down, and proper personal protective equipment should be worn. 

                                                                    For example: In an ATV71HC25N4 a customer found a loose X3 connector from the control board to the board behind and above the control board. This connector was on a ribbon cable that was about 1 inch by 1 inch. Drive ran OK after this was reseated.

                                                                    What can I use for a gateway between Ethernet TCP/IP to modbus for an ATV312 drive?

                                                                    Issue:
                                                                    Ethernet TCP/IP to modbus gateway

                                                                    Product Line:
                                                                    ATV312, ATV31

                                                                    Environment:
                                                                    All models and serial numbers

                                                                    Cause:
                                                                    None

                                                                    Resolution:
                                                                    Both EGX100SD and TSXETG100 can be used.  The EGX100SD is rated at a higher temperature for when used in an enclosed panel.  The TSXETG100 is for an open style.

                                                                    Why does the fan on my drive run continously when it is cold?

                                                                    Issue:
                                                                    Fan continues to run

                                                                    Product Line:
                                                                    ATV312

                                                                    Environment:
                                                                    All models and serial numbers

                                                                    Cause:
                                                                    The fan should not run continously.  The fan should come on when the drive thermal state reaches 70% and stop when it drops below 60%.

                                                                    Resolution:
                                                                    The drive can operate with the heatsink fan running continously.  If this is undesirable the drive can be repaired or replaced.

                                                                    The ATV58HU18M2( V3.1) will operate and run normally. However, the ATV58HU18M2 will display "nst" when VW3A58310 Ethernet card is installed on it. We...

                                                                    Goals and Symptoms

                                                                    The ATV58HU18M2( V3.1) will operate and run normally. However, the ATV58HU18M2 will display "nst" when VW3A58310 Ethernet card is installed on it. We have confirmed there has no "freewheel" or "fast stop" is assigned to I/O. How to solve this problem from "nst" to "rdy" in order to operate the ATV58 by AI1when Ethernet card is installed?

                                                                    Causes and Fixes

                                                                    In fact this function ( Forced local mode ) is not directly possible with the ATV-58 on V3.1 ( corrected on V4.xx ) but avalaible on the 58F.

                                                                    To solve it, use the Web server ( information on page 48 §8.6.3 from the Ethernet card user manual ). Replace your 58 by 58F or waiting November for V4.xx.



                                                                     


                                                                    Legacy KB System (APS) Data: RESL156488 V3.0, Originally authored by on , Last Edited by on
                                                                    Related ranges: Altivar 58

                                                                    Is there a problem using Altivar 61 or Altivar 71 drives delta power system?

                                                                    Issue:
                                                                    IWants to use Altivar 61 or Altivar 71 drives on delta power system.

                                                                    Product Line:
                                                                    Altivar ATV61 and ATV71

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Needs to know if the RFI filter needs to be disabled when using a corner grounded delta system?

                                                                    Resolution:
                                                                    As long as the input voltage remains within the normal range there should not be a problem.
                                                                    This should be treated the same way as an impedance grounded system.
                                                                    Remove the jumper to the left of the power terminal.
                                                                    See the section of the installation manual for Operation on an IT (Isolated or impedance grounded neutral) system for details.
                                                                    See the drives installation manual for more information and location of the RFI's filter tab.

                                                                    The figure 1 example below is for the low horsepower ATV61 and ATV71 drives.


                                                                                                                       Figure 1.

                                                                     

                                                                    Can the analog output of the ATV61 or ATV71 be set up as 0-10 VDC instead of 4-20 mA?

                                                                    Issue:
                                                                    Can the analog output of the ATV61 or ATV71 be set up as 0-10 VDC instead of 4-20 mA?

                                                                    Product Line:
                                                                    ATV61 and ATV71

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    NA

                                                                    Resolution:
                                                                    Yes.
                                                                    Go to the Input/Output menu (1.5) and set AO1 type to voltage (0-10v range). Set AO1 assignment to the proper setting. The minimum and maxim range can also be adjusted inside the 0-10 V or 4-20  mA ranges.


                                                                     

                                                                    Are the ATV61 or ATV71 drives available in type 4 or 4X enclosure?

                                                                    Issue:
                                                                    Are the ATV61 or ATV71 drives available in type 4 or 4X enclosure?

                                                                    Product Line:
                                                                    Altivar ATV61 and ATV71 open type drives

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Needs to get the ATV61 and ATV71 drive in a NEMA 4 or 4X stand alone enclosure.

                                                                    Resolution:
                                                                    There is not a standard offering for type 4 or 4X enclosures for our drives.
                                                                    It may be possible to install the drive in a properly selected enclosure by a local panel builder or contractor.
                                                                    Or, contact a local SquareD field office for assistance. They may be able to offer assistance with other options.


                                                                     

                                                                    Why is the keypad not included with ATV61 and ATV71 drives?

                                                                    Issue:
                                                                    Why is the keypad not included with ATV61 and ATV71 drives?

                                                                    Product Line:
                                                                    Altivar 61 and 71 drives

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Customer concerned whether the HMI came with the drive

                                                                    Resolution:
                                                                    For all ATV61 and ATV71 drives without the letter Z at the end of the part number the keypad is included.
                                                                    However, it is easy to not notice the keypad in the packaging material. The keypad is located inside folded cardboard that also functions as packing material. Check inside all folded cardboard packing materials. There is no sticker to indicate that the keypad is inside.

                                                                    ATV61 & ATV71 drives with the letter Z at the end of the part number do not include the removable LCD HMI keypad display. These units do have a simplified LED display and programming keys on the face of the control board itself. The removable LCD HMI keypad display may be installed on these units.


                                                                     

                                                                    What would cause the motor to jerk up and down when running an ATV312 drive?

                                                                    Issue:
                                                                    What would cause the motor to jerk up and down when running an ATV312 drive?

                                                                    Product Line:
                                                                    Altivar ATV31 and ATV312

                                                                    Environment:
                                                                    All

                                                                    Cause:
                                                                    Motor is not running smooth its jerking back and forth.

                                                                    Resolution:
                                                                    Check the motor nameplate for the correct motor data.  Enter this data into the DRC and SET menu 
                                                                    DRC menu enter
                                                                    BFr= 60hz
                                                                    UNS= 230vac or 460vac motor voltage
                                                                    FRS= 60hz 
                                                                    NCr= 2.4 amps  for whats stamped on the motor name plate
                                                                    COS= .80
                                                                    UFT= Change to L

                                                                    SET menu 
                                                                    ACC= 1 to 10 seconds
                                                                    DEC= 1 to 10 seconds
                                                                    LSP=  Choose
                                                                    HSP= Choose
                                                                    ITh= 2.4 amps or whats stamped on the motor name plate
                                                                    URF= 40%.

                                                                    What is the recommended Fuse or Circuit Breaker (OCPD) size for Altivar 61 drives?

                                                                    Refer to the attached Quick Start Annex, document S1B86981. 
                                                                     

                                                                    Which ATV71 drives have the built in braking transistor?

                                                                    Models with a rating of 160KW (250HP) or less have a built-in braking transistor.
                                                                    ATV71H...M3, ATV71H...M3X and ATV71H075N4 to HC16N4 drives have a built-in dynamic brake transistor.
                                                                    For ATV71HC20N4 to HC50N4 drives, a separate braking unit must be used.


                                                                    CTA-ID : 2026409

                                                                    What is the ATV28 replacement kit part number for the size 7 ATV31HU22M2, ATV31HU22M2, ATV31HU30M3X, ATV31HU40M3X, ATV31HU22N4,
                                                                    ATV31HU30N4, ATV31HU40N4, ATV31HU22S6X, ATV31HU40S6X units?

                                                                    Issue:   What is the ATV28 replacement kit part number for the size 7 ATV31HU22M2, ATV31HU22M2, ATV31HU30M3X, ATV31HU40M3X, ATV31HU22N4,<br />ATV31HU30N4, ATV31HU40N4, ATV31HU22S6X, ATV31HU40S6X units?
                                                                     
                                                                    Product Line:   ATV31
                                                                     
                                                                    Environment:  ATV31HU22M2, ATV31HU22M2, ATV31HU30M3X, ATV31HU40M3X, ATV31HU22N4,<br />ATV31HU30N4, ATV31HU40N4, ATV31HU22S6X, ATV31HU40S6X 
                                                                     
                                                                    Cause:   ATV28 conversion kit
                                                                     
                                                                    Resolution:   
                                                                    VW3A31824


                                                                     

                                                                    Do the electronic boards of the Altivar 61 and Altivar 71 drives have conformal coating?

                                                                    Issue:
                                                                    Do the electronic boards of the Altivar 61 and Altivar 71 drives have conformal coating?

                                                                    Product Line:
                                                                    Altivar ATV61 and ATV71

                                                                    Environment:
                                                                    Suffix S337 only

                                                                    Cause:
                                                                    Needs to know if you can order the ATV61 ATV71 drive with conformal coating?

                                                                    Resolution:
                                                                    For the ATV61 & ATV71 drives there is an option to have product treated for increased protection for dusty and corrosive environments. This product is not stocked. Add 'S337' to the end of the catalog number and multiply the listed price by 1.2 to obtain new price. With this option, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils. This option is standard on 55kW/75HP @ 230 Vac and higher & 90kW/125HP @ 460 Vac and higher.

                                                                    The standard ATV61 and ATV71 drives are designed for maximum ambient pollution as follows:
                                                                    ATV71:
                                                                    H...M3, 71HD11M3X, HD15M3X, H075N4 to HD18N4 are Degree 2 conforming to IEC/EN 61800-5-1
                                                                    HD18M3X to HD75M3X, HD22N4 to HC50N4 are Degree 3 conforming to IEC/EN 61800-5-1

                                                                    ATV61:
                                                                    H...M3, HD11M3X, HD15M3X, H075N4 to HD18N4 are Degree 2 conforming to IEC/EN 61800-5-1
                                                                    HD18M3X to HD90M3X, HD22N4 to HC63N4 are Degree 3 conforming to IEC/EN 61800-5-1


                                                                     

                                                                    What is part number VW3A4416?

                                                                    Issue:
                                                                    What is part number for an EMC filter for the Altivar 12 drives?

                                                                    Product Line:
                                                                    Altivar 12, ATV12, ATV11

                                                                    Environment: 
                                                                    ATV12H018F1
                                                                    ATV12H037F1
                                                                    ATV12H018M2
                                                                    ATV12H037M2
                                                                    ATV12H055M2
                                                                    ATV12H075M2
                                                                    ATV12P037F1
                                                                    ATV12P037M2
                                                                    ATV12P055M2
                                                                    ATV12P075M2

                                                                    Cause:
                                                                    EMC Filter

                                                                    Resolution:
                                                                    Part number VW3A4416 is an externally mounted EMC filter that will fit these drives.