Quantcast

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(160kW)/400V(315kW)

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(160kW)/400V(315kW)

Altistart 22 Soft Starter ATS22 Control, 220V Power 230V(160kW)/400V(315kW)

Item Number: ATS22C59Q

Retail
$17,007.32
RRP (Inc. GST)

Product Dimensions

Width icon

Width304 mm

Height icon

Height455 mm

Depth icon

Depth339.7 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Altistart 22

Product or component type

soft starter

Product destination

asynchronous motors

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

IP degree of protection

IP00

Function available

internal bypass

Output current

0.4...1 Icl adjustable

Communication port protocol

Modbus

Connector type

1 RJ45

Protection type

  • phase failure: line
  • thermal protection: motor
  • thermal protection: starter
    • Marking

      CE

      Height

      455 mm

      Width

      304 mm

      Depth

      339.7 mm

      Net weight

      50 kg

      Standards

      EN/IEC 60947-4-2

      Product certifications

    • UL
    • CCC
    • C-Tick
    • CSA
    • GOST
      • Relative humidity

        0-95 % without condensation or dripping water conforming to EN/IEC 60068-2-3

        Ambient air temperature for operation

      • -10-40 °C (without derating)
      • 40-60 °C (with current derating 2.2 % per °C)
        • Ambient air temperature for storage

          -25-70 °C

          REACh Regulation

          Free of Substances of Very High Concern above the threshold

          EU RoHS Directive

          Pro-active compliance (Product out of EU RoHS legal scope)

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          X

          Environmental Disclosure

          ENVPEP100402EN

          Circularity Profile

          ENVEOLI110805EN

          California proposition 65

          WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

          Others

          Product specific application

          pumps and fans

          Component name

          ATS22

          Network number of phases

          3 phases

          [Us] rated supply voltage

          230...440 V - 15...10 %

          Motor power kW

        • 160 kW 230 V
        • 315 kW 400 V
        • 355 kW 440 V
          • Factory setting current

            560 A

            Power dissipation in W

            251 W for standard applications

            Utilisation category

            AC-53A

            Type of start

            start with torque control (current limited to 3.5 In)

            IcL starter rating

            590 A for connection in the motor supply line for standard applications

            Assembly style

            with heat sink

            Supply voltage limits

            195-484 V

            Supply frequency

            50...60 Hz - 10...10 %

            Network frequency

            45...66 Hz

            Device connection

          • to the motor delta terminals
          • in the motor supply line
            • [Uc] control circuit voltage

              230 V - 15...10 % 50/60 Hz

              Control circuit consumption

              20 W

              Discrete output number

              2

              Discrete output type

            • relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
            • relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
              • Minimum switching current

                100 mA at 12 V DC (relay outputs)

                Maximum switching current

              • 5 A 250 V AC resistive 1 relay outputs
              • 5 A 30 V DC resistive 1 relay outputs
              • 2 A 250 V AC inductive 0.4 20 ms relay outputs
              • 2 A 30 V DC inductive 7 ms relay outputs
                • Discrete input number

                  3

                  Discrete input type

                  (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm

                  Discrete input voltage

                  24 V <= 30 V

                  Discrete input logic

                  positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA

                  PTC probe input

                  750 Ohm

                  Communication data link

                  serial

                  Physical interface

                  RS485 multidrop

                  Transmission rate

                  4800, 9600 or 19200 bps

                  Installed device

                  31

                  Type of cooling

                  forced convection

                  Operating position

                  vertical +/- 10 degree

                  Power range

                • 110-220 kW at 200-240 V 3 phases
                • 250-500 kW at 380-440 V 3 phases
                  • Motor starter type

                    soft starter

                    Electromagnetic compatibility

                  • conducted and radiated emissions level A conforming to IEC 60947-4-2
                  • damped oscillating waves level 3 conforming to IEC 61000-4-12
                  • electrostatic discharge level 3 conforming to IEC 61000-4-2
                  • immunity to electrical transients level 4 conforming to IEC 61000-4-4
                  • immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
                  • voltage/current impulse level 3 conforming to IEC 61000-4-5
                    • Vibration resistance

                    • 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-6
                    • 1.5 mm (f= 2-13 Hz) conforming to EN/IEC 60068-2-6
                      • Shock resistance

                        15 gn for 11 ms conforming to EN/IEC 60068-2-27

                        Noise level

                        56 dB

                        Pollution degree

                        level 2 conforming to IEC 60664-1

                        Operating altitude

                      • <= 1000 m without derating
                      • > 1000...< 2000 m with current derating of 2.2 % per additional 100 m
                        • Unit Type of Package 1

                          PCE

                          Number of Units in Package 1

                          1

                          Package 1 Weight

                          39.75 kg

                          Package 1 Height

                          50 cm

                          Package 1 width

                          40 cm

                          Package 1 Length

                          60 cm

                          WEEE

                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                          Show all specifications

                          Documents & downloads

                          hide show
                          Filter items
                          • All

                          • Product Brochures

                          • CAD Files and Packs

                          • Technical Data Catalogues

                          • Product Environmental

                          • End of Life Manual

                          • Installation Instruction

                          • Operating Manuals

                          • Certificates (MSDS)

                          • Marine Certificate

                          • eTechPub

                          • Declaration of Conformity

                          • DTM Files

                          • Software - Release