iID   Differential switches 2P

Acti 9 iID, RCCB, 2P, 100A, 30mA, Type A

Catalogue Number: A9R21291
iID   Differential switches 2P
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
iID
Range
Acti 9
Product name
Acti 9 iID
Product or component type
residual current circuit breaker (RCCB)
Device short name
iID
Poles description
2P
Neutral position
left
[In] rated current
100 A
Network type
AC
Earth-leakage sensitivity
30 mA
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
Device location in system
outgoer
Network frequency
50/60 Hz
[Ue] rated operational voltage
220...240 V AC 50/60 Hz
Residual current tripping technology
voltage independent
Rated breaking and making capacity
  • Idm 1500 A
  • Im 1500 A
    • Rated conditional short-circuit current
      10 kA
      [Ui] rated insulation voltage
      500 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      6 kV
      Surge current
      250 A
      Contact position indicator
      yes
      Control type
      toggle
      Mounting mode
      clip-on
      Mounting support
      DIN rail
      Comb busbar and distribution block compatibility
      top or bottom: tooth
      Connection pitch
      9 mm pitches
      4
      Height
      91 mm
      Width
      36 mm
      Depth
      73.5 mm
      Net weight
      0.21 kg
      Mechanical durability
      20000 cycles
      Electrical durability
      AC-1: 10000 cycles
      Locking options description
      padlocking device
      Connections - terminals
    • single terminal top or bottom 1-35 mm² rigid
    • single terminal top or bottom 1-25 mm² flexible
    • single terminal top or bottom 1-25 mm² flexible with ferrule
      • Wire stripping length
        14 mm for top or bottom connection
        Tightening torque
        3.5-3.5 N.m top or bottom
        Market segment
        small commercial
        Compatibility code
        iID
        Standards
        EN/IEC 61008-1
        IP degree of protection
      • IP20 conforming to IEC 60529
      • IP40 (modular enclosure) conforming to IEC 60529
        • Pollution degree
          3
          Electromagnetic compatibility
          8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
          Ambient air temperature for operation
          -25-60 °C
          Ambient air temperature for storage
          -40-85 °C
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP1409014EN
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Frequently Asked Questions

          hide show

          What is the part number for a 3phase 100amp 30mA trip RCD unit?

          The part number for a 3 phase  ,100amp , 30mA trip RCD unit is - A9R21491

          What do I need to put together a single phase 30A 56 Series RCD

          Use 56CB4 + A9R51240 40amp RCCB

          What is the code of the Domae version of a 23358 40A 2p RCCB?

          It is a DOM16695

          Is the Acti 9 range of RCCB 120v ac rated?

          All Acti9 RCCB's are rated 230-240v AC only

          What is the Australian equivalent for the A9R41263

          For a Type A RCCB, the following part name will be suitable: A9R51263
          For a Type AC RCCB, the following part name will be suitable: A9R41263

          What is the part number for 300mA sensitivity RCCB, in 63amp?

          The part number will be A9R25263.
          For more specifications please follow the below link,
          https://www.schneider-electric.co.uk/en/product/A9R25263/iid---rccb---2p---63a----300ma----a-type/
          Image result for A9R25263 schneider


           

          Is there a shunt trip that can be used in conjunction with a iSW series?

          No unfortunately the ISW series can't be used with shunt release.

          For further information please visit Global Specialist in Energy Management | Schneider Electric

          Square D Sepam Series 20, 40 and 80 Digital Relays Product Line Overview (ANSI), 3000BR0404R8/07, August 2007

          Goals and Symptoms

          Square D Sepam Series 20, 40 & 80 Digital Relays Product Line Overview, 3000BR0404R8/07, August 2007

          Facts and Changes

          Keywords:
          3000BR0404R8
          Quick Selection Guide

          Causes and Fixes

          See attachment


          AEDL3


          • (Removed Image URL: /PubResEXPORT.nsf/2b87ee90be777fc085257c28006ee4ef/d59f3211419509c1c1257426001099a7/fl_block_5/0.2B76?OpenElement&FieldElemFormat=gif)
            Date Created: February 25, 2008
            Last Revised: April 8, 2008
            Public
            Original Author: JJ
            All content © 1992-2008 Schneider Electric

          Legacy KB System (APS) Data: RESL191625 V1.0, Originally authored by PhHa on 04/09/2008, Last Edited by PhHa on 04/09/2008
          Related ranges: Sepam series 80, Sepam series 40, Sepam series 20, Sepam accessories, ACE 9XX