Quantcast

Acti 9 Miniature Circuit Breaker, C60H, 2 Poles, 4A, C Curve

Acti 9 Miniature Circuit Breaker, C60H, 2 Poles, 4A, C Curve

Acti 9 Miniature Circuit Breaker, C60H, 2 Poles, 4A, C Curve

Item Number: A9N61524

Retail
$207.98
RRP (Inc. GST)

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

C60

Range

Acti 9

Product or component type

miniature circuit-breaker

Device application

distribution

Product compatibility

  • C60 accessories
  • C60 auxiliary
    • Market segment

    • residential
    • small commercial
      • Sustainable offer status

        Green Premium product

        Warranty

        18 months

        Physical

        [In] rated current

        4 A at 25 °C

        [Ue] rated operational voltage

        500 V DC

        Control type

        toggle

        Local signalling

        ON/OFF indication

        Mounting mode

        fixed

        Mounting support

        35 mm symmetrical DIN rail

        Net weight

        0.256 kg

        Mechanical durability

        20000 cycles

        Electrical durability

      • 3000 cycles 500 V DC
      • 6000 cycles 500 V DC
        • Standards

        • EN 60947-2
        • IEC 60947-2
          • Ambient air temperature for operation

            -25-70 °C

            Ambient air temperature for storage

            -40-85 °C

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            REACh free of SVHC

            Yes

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP120608EN_V0

            Others

            Product name

            Acti 9 C60H-DC

            Device short name

            C60H-DC

            Poles description

            2P

            Number of protected poles

            2

            Network type

            DC

            Trip unit technology

            thermal-magnetic

            Curve code

            C

            Breaking capacity code

            H

            Breaking capacity

          • 10 kA Icu at 440 V DC conforming to EN 60947-2
          • 10 kA Icu at 440 V DC conforming to IEC 60947-2
          • 6 kA Icu at 500 V DC conforming to EN 60947-2
          • 6 kA Icu at 500 V DC conforming to IEC 60947-2
          • 20 kA Icu at 220 V DC conforming to GB 14048.2
          • 20 kA Icu at 220 V DC conforming to IEC 60947-2
          • 20 kA Icu at 250 V DC conforming to GB 14048.2
          • 20 kA Icu at 250 V DC conforming to IEC 60947-2
            • Utilisation category

            • category A conforming to EN 60947-2
            • category A conforming to IEC 60947-2
              • Suitability for isolation

              • yes conforming to IEC 60947-2
              • yes conforming to EN 60947-2
                • Network frequency

                  50/60 Hz

                  [Ics] rated service breaking capacity

                • 15 kA 75 % conforming to EN 60947-2 - 220 V DC
                • 15 kA 75 % conforming to IEC 60947-2 - 220 V DC
                • 15 kA 75 % conforming to EN 60947-2 - 250 V DC
                • 15 kA 75 % conforming to IEC 60947-2 - 250 V DC
                • 4.5 kA 75 % conforming to EN 60947-2 - 500 V DC
                • 4.5 kA 75 % conforming to IEC 60947-2 - 500 V DC
                • 7.5 kA 75 % conforming to EN 60947-2 - 440 V DC
                • 7.5 kA 75 % conforming to IEC 60947-2 - 440 V DC
                  • [Ui] rated insulation voltage

                  • 500 V DC conforming to IEC 60947-2
                  • 500 V DC conforming to EN 60947-2
                    • [Uimp] rated impulse withstand voltage

                    • 6 kV conforming to EN 60947-2
                    • 6 kV conforming to IEC 60947-2
                      • Contact position indicator

                        yes

                        Comb busbar and distribution block compatibility

                        top or bottom: standard

                        9 mm pitches

                        4

                        Provision for padlocking

                        padlockable

                        Locking options description

                        in position O

                        Tightening torque

                        power circuit: 2.5-2.5 N.m top or bottom

                        Earth-leakage protection

                        without

                        Compatibility code

                        C60H-DC

                        Pollution degree

                      • 3 conforming to EN 60947-2
                      • 3 conforming to IEC 60947-2
                        • Overvoltage category

                          IV

                          Tropicalisation

                          2 conforming to IEC 60068-2

                          Operating altitude

                          2000 m

                          Unit Type of Package 1

                          PCE

                          Number of Units in Package 1

                          1

                          Package 1 Weight

                          228 g

                          Package 1 Height

                          7.4 cm

                          Package 1 width

                          3.6 cm

                          Package 1 Length

                          8.4 cm

                          Unit Type of Package 2

                          BB1

                          Number of Units in Package 2

                          6

                          Package 2 Weight

                          1.418 kg

                          Package 2 Height

                          2.87 cm

                          Package 2 width

                          30 cm

                          Package 2 Length

                          20 cm

                          Unit Type of Package 3

                          S03

                          Number of Units in Package 3

                          72

                          Package 3 Weight

                          17.479 kg

                          Package 3 Height

                          30 cm

                          Package 3 width

                          30 cm

                          Package 3 Length

                          40 cm
                          Show all specifications

                          Documents & downloads

                          hide show

                          Frequently Asked Questions

                          hide show

                          Wanted to know if A9N18524 can be used as 3 pole breaker instead of 4 pole?

                          Yes, customer can use the 3 pole and leave 4 pole open.

                          What is the part number of a 2 pole, 50A, 6KA, C curve DC circuit breaker?

                          A9N61538 is the part number of a 2 pole, 50A, 6KA, C curve C60H DC circuit breaker.
                          For further information, please visit https://www.schneider-electric.co.uk/en/product/A9N61538/miniature-circuit-breaker---c60h---2-poles---50-a---c-curve/
                          Schneider Eletric A9N61538 Picture
                           

                          What is the code for a 2 pole, 10A, MCB suitable for 300Vdc?

                          The code will be A9N61528. This is C curve, 6kA, and rated up to 500Vdc

                          For more information see below:
                          https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9N61528
                           

                          What is the part code for a 2A 24v DC rated MCCB

                           The part code is MGN61522

                          What is the replacement part for a 26896 RCB?

                          The replacement part is a A9D61820.
                          A9D11220 is best solution
                          A9D11820 is an alternative 1 pole wide but no Neutral switching
                          A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA