iEM3000 Series Triphase kWh meter 63A multi-tariff MID - iEM3115

Acti 9 Triphase Kwh iEM3115 Energy Meter, 63A, 2 Digital I, Multi-Tariff

Catalogue Number: A9MEM3115
iEM3000 Series Triphase kWh meter 63A multi-tariff MID - iEM3115
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Acti 9
Product name
Acti 9 iEM3000
Device short name
iEM3115
Product or component type
energy meter
Market segment
Poles description
  • 1P + N
  • 3P + N
  • 3P
    • Type of measurement
      active energy
      Device application
    • sub billing
    • multi-tariff
      • Accuracy class
      • class 1 active energy conforming to IEC 62053-21
      • class 1 active energy conforming to IEC 61557-12
      • class B active energy conforming to EN 50470-3
        • Analogue input type
          direct input
          [In] rated current
          63 A
          Rated voltage
        • 100-277 V
        • 173-480 V
          • Network frequency
          • 60 Hz
          • 50 Hz
            • Technology type
              electronic
              Display type
              LCD display
              Sampling rate
              32 samples/cycle
              Measurement current
              0-63 A
              Maximum value measured
              99999999.9 kWh
              Information displayed
              tariff (4)
              Communication port protocol
              -
              Communication port support
              -
              Local signalling
            • green indicator light: power ON
            • yellow flashing LED: accuracy checking
              • Number of inputs
                2 digital 0...5 V/11...40 V 24 V DC
                Number of outputs
                0
                Mounting mode
                clip-on
                Mounting support
                DIN rail
                Connections - terminals
                screw terminals 16-16 mm² cable(s)
                Overvoltage category
                III
                Standards
              • IEC 62053-23
              • IEC 61010
              • IEC 61557-12
              • IEC 62053-21
              • IEC 61036
              • UL 61010-1
                • Product certifications
                • CE conforming to IEC 61010 (safety)
                • CE conforming to EN 61557-12 (power monitor)
                • CE conforming to IEC 61326-1 (EMC)
                • cULus conforming to UL 61010 (safety)
                • cULus conforming to ANSI C12.20 (sub-meter)
                • EAC (sub-meter)
                • RCM conforming to NMI M 6-1 (sub-meter)
                • UL
                • MID conforming to EN 50470-3 (sub-meter)
                • MID conforming to EN 62052 (sub-meter)
                  • Market segment
                  • residential
                  • small commercial
                    • Compatibility code
                      iEM3115
                      IP degree of protection
                    • IP40 front panel: conforming to IEC 60529
                    • IP20 body: conforming to IEC 60529
                      • Pollution degree
                        2
                        Relative humidity
                        5-95 % at 50-50 °C
                        Ambient air temperature for operation
                      • -25-55 °C - MID
                      • -25-60 °C - NMI
                      • -25-60 °C - IEC
                        • Ambient air temperature for storage
                          -40-85 °C
                          Operating altitude
                          < 2000 m
                          9 mm pitches
                          10
                          Width
                          90 mm
                          Height
                          95 mm
                          Depth
                          69 mm
                          Sustainable offer status
                          Green Premium product
                          EU RoHS Directive
                          Compliant
                          Mercury free
                          Yes
                          RoHS exemption information
                          Yes
                          China RoHS Regulation
                          X
                          Environmental Disclosure
                          ENVPEP111276EN
                          Circularity Profile
                          ENVEOLI111261EN_V1
                          WEEE
                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                          California proposition 65
                          WARNING: This product can expose you to chemicals including: Carbon-black extracts and Bisphenol A (BPA) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
                          Warranty
                          18 months

                          Documents & downloads

                          hide show
                          Filter items
                          • All

                          • CAD Files and Packs

                          • Product Brochures

                          • Movies

                          • Technical Data Catalogues

                          • Technical Leaflet

                          • End of Life Manual

                          • Product Environmental

                          • Installation Instruction

                          • Handout

                          • Data Bulletin

                          • Operating Manuals

                          • Specifications

                          • Case Studies

                          • Certificates (MSDS)

                          • White Paper

                          • Declaration of Conformity

                          • Software - Released

                          • Firmware - Updates

                          • Software - Updates

                          Frequently Asked Questions

                          hide show

                          What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                          A9MEM3155 - 16mm
                          A9MEM3355 - 50mm
                          For further information , visit links below:-
                          https://www.schneider-electric.com.au/en/search/A9MEM3155
                          https://www.schneider-electric.com.au/en/search/A9MEM3355
                          User-added image

                          Is the Acti 9 A9MEM3110 3 phase?

                          Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                          What is the alternate part number for 17072

                           Replacement is a A9MEM3210

                          Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                          We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                           

                          What is the alternative code for 17072?

                          A9MEM3210

                          What is the replacement for a 17072

                           The replacement is a A9MEM3210.

                          What are the power terminal sizes on the A9MEM3100?

                          The power terminal sizes of the iEM3100 meter will take 16mm cable
                          see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                          Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                          The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                           

                          Which KWH meter will measure Solar inputs with Modbus connections?

                          What is the replacement for 15467 Power meter with 100/5 CTs?

                          What is the part number for Single phase KWH meter?

                          The part number for Single phase KWH meter will be a - A9MEM2105.
                          Please refer the below link for more information,
                          https://www.schneider-electric.com/en/product/A9MEM2105/modular-single-phase-power-meter-iem2105---230v---63a-with-pulse/
                          Image result for a9mem2105 schneider



                           

                          ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                          The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                          Can the IEM3000 series read energy output from a Solar Panel?

                          To be able to measure the energy out from a Solar Panel a meter needs to be able to do Four Quadrant Calculation.

                          This means it is capable of Identification of imported and exported active and reactive energy allows you to monitor energy flow in both directions: delivered from the utility and produced on-site.

                          In the iEM3000 series the following meters are capable of Four Quadrant Calculation.

                          iEM31** range - iEM3135, iEM3155, iEM3165, and iEM3175
                          iEM32** range - iEM3235, iEM3255, iEM3265, and iEM3275
                          iEM33** range - iEM3335, iEM3355, iEM3365, and iEM3375
                          iEM34** range - iEM3455, iEM3465, iEM3555, and iEM3565


                           

                          Power Meter Communication issue, registers not reading the correct value.

                          The Power meters, based on the manufacturing location may have an offset. 

                          In some meters the registers starts from Zero and some it is taken account from 1. So the published register list varies accordingly. 

                          For Ex: If Register 2017 is for Frequency of the meters it will read 50 HZ. 
                          But for the meter with offset the the Register 2016 will read 50HZ. 

                          So it is good to check if the meter has got an Offset before proceeding with the communication issue. 

                          Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                          Issue
                          Rogowski Coil CT's may require secondary lead length extension.

                          Product Line
                          A9MEM3500 meters
                          EM4200 meters
                          EM3500 meters
                          U018 Rogowski Coil Current Transformers

                          Environment
                          Metering & Power Monitoring

                          Cause
                          The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                          Resolution
                          Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                          This measurement only applies to the primary length only.
                          This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                          The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                          It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                          Because of this, one may need to extend the length of the secondary leads from the current transformers.

                          Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                          The conductors used must be a standard 24 gauge twisted cable.

                          What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                          The product code is A9MEM2000. Please see the attached datasheet for more information.
                           

                          On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                          This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                          Where can I find the register list for the iEM3100, iEM3200, and iEM3300 series of meters?

                          Issue
                          A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
                           
                          Product Line
                          iEM3100, iEM3200, iEM3300 series
                           
                          Environment
                          iEM3100, iEM3200, iEM3300 series
                           
                          Cause
                          A user may need the register list for the iEM3100, iEM3200, and iEM3300 series of meters.
                           
                          Resolution
                          The user manual for the iEM3100, iEM3200, and iEM3300 series of meters (document reference number DOCA0005EN-04) has a register list in Chapter 5: Communications via Modbus RS-485. See page 57 of the pdf document attached   (doca0005en-04.pdf)

                          What are the Dimensions for the A9MEM2000 single phase power meter?

                            9 mm pitches 2  
                           
                           
                            Width 18 mm  
                           
                           
                            Height 95 mm  
                           
                           
                            Depth 67 mm  
                           
                           
                            Product weight 0.073 kg