PowerTag 1PN MAX 63A Eenergy Sensor

PowerTag 1PN MAX 63A Eenergy Sensor

PowerTag 1PN MAX 63A Eenergy Sensor

Item Number: A9MEM1560

Retail
$254.10
RRP (Inc. GST)

Product Dimensions

Width icon

Widthsensor element: 18 mm

Height icon

Heightsensor element: 20 mm

Depth icon

Depthsensor element: 44.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

PowerLogic

Product or component type

energy sensor

Market segment

  • buildings: breaker voltage monitoring
  • buildings: cost allocation
  • buildings: overload alarm
    • Product destination

      switchboard

      Sustainable offer status

      Green Premium product

      Physical

      Range compatibility

    • Acti 9 iCV40
    • Vigi iC40
    • Vigi iC60
    • Acti 9 iDD40 XA
    • Acti 9 iCV40 XA
    • Vigi iDT40
      • Mounting support

        on circuit breaker

        Mounting mode

        by screws (terminals)

        [Ue] rated operational voltage

        200...240 V AC, +/- 20 %

        Standards

      • IEC 61557-12
      • IEC 61010-1
      • IEC 61010-2-030
      • IEC 61326-1
      • ETSI EN 300 328
        • Height

          sensor element: 20 mm

          Width

          sensor element: 18 mm

          Depth

          sensor element: 44.5 mm

          Net weight

          16 g

          Ambient air temperature for operation

          -25-60 °C

          Ambient air temperature for storage

          -40-85 °C

          IP degree of protection

          IP20 conforming to IEC 60529

          IK degree of protection

          IK05

          Relative humidity

          0-95 % at 45-45 °C conforming to IEC 60721-3-3

          Environmental characteristic

        • dustproof class 3S3 conforming to IEC 60721-3-3
        • salt mist class 3C2 conforming to IEC 60721-3-3
          • EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP1605012

            Circularity Profile

            ENVEOLI1605012

            Others

            Product name

            PowerTag A9 F63

            Poles description

            1P + N

            Max current

            63 A

            [Ib] basic current

            10 A

            Starting current

            40 mA

            Saturation current

            130 A

            Product specific application

          • cost allocation
          • load monitoring
          • circuit monitoring
          • overload alarm
          • energy management
            • Concentrator compatibility

            • Acti9 Smartlink SI B
            • Acti9 Smartlink SI D
            • Acti9 PowerTag Link C
            • Acti9 PowerTag Link
            • Acti9 PowerTag Link HD
            • Harmony Hub
              • Type of measurement

              • active energy
              • current
              • voltage
              • power factor
              • active power
                • Accuracy class

                • class 1 current conforming to IEC 61557-12
                • class 0.5 voltage conforming to IEC 61557-12
                • class 1 active power conforming to IEC 61557-12
                • class 1 active energy conforming to IEC 61557-12
                • class 1 power factor conforming to IEC 61557-12
                  • Mounting location

                    top or bottom

                    Event management

                    voltage loss with measured current at voltage loss

                    Transmission support medium

                    radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4

                    Maximum emission power

                    10 mW

                    Form factor

                    flex

                    Electrical connection

                    wires with cable end

                    Cable cross section

                  • 1 rigid cable 1.5-16 mm²
                  • 2 stranded cable 1.5-2.5 mm²
                  • 2 rigid cable 1.5-2.5 mm²
                  • 1 stranded cable 1.5-16 mm²
                    • Cable length

                      0.25 m

                      Cable composition

                      1 x 0.33 mm²

                      Network frequency

                    • 50 Hz
                    • 60 Hz
                      • Maximum power consumption in VA

                        1 VA

                        Compatibility code

                        PowerTag A9 P63

                        Quality labels

                        CE

                        Directives

                        2014/53/EU - radio equipment directive

                        Operating altitude

                        0...2000 m

                        Overvoltage category

                        III conforming to IEC 61010-1

                        Measurement category

                        category III conforming to IEC 61010-2-030

                        Pollution degree

                        3

                        Vibration resistance

                        3M4 conforming to IEC 60721-3-3

                        Unit Type of Package 1

                        PCE

                        Number of Units in Package 1

                        1

                        Package 1 Weight

                        58 g

                        Package 1 Height

                        7.8 cm

                        Package 1 width

                        6.8 cm

                        Package 1 Length

                        7 cm

                        Unit Type of Package 2

                        S02

                        Number of Units in Package 2

                        30

                        Package 2 Weight

                        2.038 kg

                        Package 2 Height

                        15 cm

                        Package 2 width

                        30 cm

                        Package 2 Length

                        40 cm

                        WEEE

                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Show all specifications

                        Documents & downloads

                        hide show
                        Filter items
                        • All

                        • Product Brochures

                        • CAD Files and Packs

                        • Technical Data Catalogues

                        • Catalog Page

                        • Installation Instruction

                        • Product Environmental

                        • End of Life Manual

                        • Operating Manuals

                        • Certificates (MSDS)

                        Frequently Asked Questions

                        hide show

                        On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                        This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                        What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                        A9MEM3155 - 16mm
                        A9MEM3355 - 50mm
                        For further information , visit links below:-
                        https://www.schneider-electric.com.au/en/search/A9MEM3155
                        https://www.schneider-electric.com.au/en/search/A9MEM3355
                        User-added image

                        Is the Acti 9 A9MEM3110 3 phase?

                        Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                        What is the alternate part number for 17072

                         Replacement is a A9MEM3210

                        ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                        The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                        What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                        The product code is A9MEM2000. Please see the attached datasheet for more information.
                         

                        What is the alternative code for 17072?

                        A9MEM3210

                        Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                        We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                         

                        Do you have a Bacnet, NMI approved kilowatt hour meter with CT's?

                        The part number for a Bacnet, NMI approved kilowatt-hour meter with CT's is a - A9MEM3265.


                         

                        What is the replacement for 15467 Power meter with 100/5 CTs?

                        Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                        Issue
                        Rogowski Coil CT's may require secondary lead length extension.

                        Product Line
                        A9MEM3500 meters
                        EM4200 meters
                        EM3500 meters
                        U018 Rogowski Coil Current Transformers

                        Environment
                        Metering & Power Monitoring

                        Cause
                        The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                        Resolution
                        Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                        This measurement only applies to the primary length only.
                        This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                        The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                        It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                        Because of this, one may need to extend the length of the secondary leads from the current transformers.

                        Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                        The conductors used must be a standard 24 gauge twisted cable.

                        What is the replacement for a 17072

                         The replacement is a A9MEM3210.
                        Show More