PowerTag A9 M63 1P+N Top
A9MEM1521
PowerTag A9 M63 1P+N Top
A9MEM1521

Acti 9 - PowerTag - 1P+N - Up Position

Catalogue Number: A9MEM1521
PowerTag A9 M63 1P+N Top
A9MEM1521
PowerTag A9 M63 1P+N Top
A9MEM1521
Retail
$254.10
RRP (Inc. GST)

Specifications

hide show
Range
PowerLogic
Product name
PowerTag A9 M63
Product or component type
energy sensor
Poles description
1P + N
Max current
63 A
[Ib] basic current
10 A
Starting current
40 mA
Saturation current
130 A
Product specific application
  • overload alarm
  • cost allocation
  • circuit monitoring
  • load monitoring
  • energy management
    • Concentrator compatibility
    • Acti9 Smartlink SI B
    • Acti9 Smartlink SI D
    • Acti9 PowerTag Link C
    • Acti9 PowerTag Link
    • Acti9 PowerTag Link HD
      • Market segment
      • buildings: breaker voltage monitoring
      • buildings: cost allocation
      • buildings: overload alarm
        • Range compatibility
        • Acti 9 iKQE RCBO
        • Multi 9 C60
        • Multi 9 ID
        • Multi 9 C32N
        • Multi 9 C65
        • Acti 9 iID
        • Acti 9 iID K
        • Acti 9 iK60
        • Acti 9 iKQ
        • Acti 9 K60
        • Acti 9 Reflex iC60
        • Acti 9 iC65
        • Acti 9 DT60
        • Acti 9 iC60 single terminal
          • Type of measurement
          • power factor
          • current
          • active energy
          • active power
          • voltage
            • Accuracy class
            • class 1 current conforming to IEC 61557-12
            • class 0.5 voltage conforming to IEC 61557-12
            • class 1 active power conforming to IEC 61557-12
            • class 1 active energy conforming to IEC 61557-12
            • class 1 power factor conforming to IEC 61557-12
              • Mounting location
                top
                Mounting support
                on circuit breaker
                Product destination
                switchboard
                Event management
                voltage loss with measured current at voltage loss
                Transmission support medium
                radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4
                Maximum emission power
                10 mW
                Form factor
                monoconnect
                Mounting mode
                by screws (terminals)
                Electrical connection
                connector tooth
                Cable cross section
              • 1 rigid cable 1.5-16 mm²
              • 2 stranded cable 1.5-2.5 mm²
              • 2 rigid cable 1.5-2.5 mm²
              • 1 stranded cable 1.5-16 mm²
                • [Ue] rated operational voltage
                  200...240 V AC, +/- 20 %
                  Network frequency
                • 50 Hz
                • 60 Hz
                  • Maximum power consumption in VA
                    1 VA
                    Standards
                  • IEC 61557-12
                  • IEC 61010-1
                  • IEC 61010-2-030
                  • IEC 61326-1
                  • ETSI EN 300 328
                    • Height
                      16.5 mm
                      Width
                      36 mm
                      Depth
                      43 mm
                      Net weight
                      17.5 g
                      Compatibility code
                      PowerTag A9 M63
                      Quality labels
                      CE
                      Directives
                      2014/53/EU - radio equipment directive
                      Operating altitude
                      0...2000 m
                      Ambient air temperature for operation
                      -25-60 °C
                      Ambient air temperature for storage
                      -40-85 °C
                      Overvoltage category
                      III conforming to IEC 61010-1
                      Measurement category
                      category III conforming to IEC 61010-2-030
                      IP degree of protection
                      IP20 conforming to IEC 60529
                      IK degree of protection
                      IK05
                      Pollution degree
                      3
                      Relative humidity
                      0-95 % at 45-45 °C conforming to IEC 60721-3-3
                      Vibration resistance
                      3M4 conforming to IEC 60721-3-3
                      Environmental characteristic
                    • dustproof class 3S3 conforming to IEC 60721-3-3
                    • salt mist class 3C2 conforming to IEC 60721-3-3
                      • Unit Type of Package 1
                        PCE
                        Number of Units in Package 1
                        1
                        Package 1 Weight
                        48 g
                        Package 1 Height
                        5 cm
                        Package 1 width
                        6 cm
                        Package 1 Length
                        8.5 cm
                        Unit Type of Package 2
                        S02
                        Number of Units in Package 2
                        48
                        Package 2 Weight
                        2.687 kg
                        Package 2 Height
                        15 cm
                        Package 2 width
                        30 cm
                        Package 2 Length
                        40 cm
                        Sustainable offer status
                        Green Premium product
                        EU RoHS Directive
                        Compliant
                        Mercury free
                        Yes
                        RoHS exemption information
                        Yes
                        China RoHS Regulation
                        Product out of China RoHS scope. Substance declaration for your information
                        Environmental Disclosure
                        ENVPEP1605012
                        Circularity Profile
                        ENVEOLI1605012
                        WEEE
                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

                        Documents & downloads

                        hide show
                        Filter items
                        • All

                        • Product Brochures

                        • CAD Files and Packs

                        • Technical Data Catalogues

                        • Catalog Page

                        • Installation Instruction

                        • End of Life Manual

                        • Product Environmental

                        • Operating Manuals

                        • Application Solutions

                        • Certificates (MSDS)

                        Frequently Asked Questions

                        hide show

                        What size cables will the termninals in the Energy Meters , A9MEM3155 & the A9MEM3355 allow?

                        A9MEM3155 - 16mm
                        A9MEM3355 - 50mm
                        For further information , visit links below:-
                        https://www.schneider-electric.com.au/en/search/A9MEM3155
                        https://www.schneider-electric.com.au/en/search/A9MEM3355
                        User-added image

                        What is the alternate part number for 17072

                         Replacement is a A9MEM3210

                        What is the alternative code for 17072?

                        A9MEM3210

                        On the PowerTag A9 F63 model, ref. A9MEM1562 if I try to be consistent with the flat cable position, the LED of the module is upwards. Should I twist the flat cable to have the LED down?

                        This has no impact on the operation but to be consistent with the rest of the range we favor the Led down, and in this case, the flat cable is twisted.

                        Can you retrieve data from the A9MEM3155 modbus meter wireless using a Modbus to WiFi converter?

                        We recommend to use  standard tested SE solution like using COM'X with Wifi dongle, which can be connected to iEM3155 over Modbus RTU and COM'X will sendthe data of meter over Wifi.

                         

                        ETSNZ - What Single Phase Check Meter does not Require a Neutral Through Connection

                        The New range of Acti9  A9MEM2150 for example only needs a N connection  - it does not require to pass the N current through it.

                        What is the replacement for 15467 Power meter with 100/5 CTs?

                        What is the replacement for a 17072

                         The replacement is a A9MEM3210.

                        Is the Acti 9 A9MEM3110 3 phase?

                        Yes, the iEM3110 kWh meter with pulse output, is a 3 phase digital meter for direct connection up to 63Amps.

                        What are the power terminal sizes on the A9MEM3100?

                        The power terminal sizes of the iEM3100 meter will take 16mm cable
                        see instruction sheet....https://eshop.schneider-electric.com/Download.aspx?infos=H808089_1.pdf;3

                        Can Rogowski Coil Current Transformers (Rope Style CT's) Be Extended in the Field? How Far?

                        Issue
                        Rogowski Coil CT's may require secondary lead length extension.

                        Product Line
                        A9MEM3500 meters
                        EM4200 meters
                        EM3500 meters
                        U018 Rogowski Coil Current Transformers

                        Environment
                        Metering & Power Monitoring

                        Cause
                        The load may be farther from the meter than the standard 8' or 12' secondary lead lengths may reach.

                        Resolution
                        Schneider Rogowski Coil Current Transformers come in primary lengths of 12", 18", 24", or 36". 
                        This measurement only applies to the primary length only.
                        This is the length that the current transformer has to connect back to itself around a conductor or set of conductors of the load to be monitored.

                        The lead length refers to the 8' or 12' that connects from the current transformer to the meter itself.

                        It is sometimes difficult to get the meter mounting location within 8' or 12' from an appropriate location to install the current transformer on the load conductors.
                        Because of this, one may need to extend the length of the secondary leads from the current transformers.

                        Either the 8' or the 12' secondary lead length version of Schneider's Rogowski Coil (U018-xxx) Current Transformers may be extended to a maximum of 20' total lead length (to include the original lead length of either 8' or 12').
                        The conductors used must be a standard 24 gauge twisted cable.

                        What is the product code for the iEM2000 Acti9 230V 40A din rail mount energy monitor?

                        The product code is A9MEM2000. Please see the attached datasheet for more information.
                         
                        Show More