Acti 9 iC60H 3P 1A…63A Miniature Circuit Breaker

Acti9 Ic60H, 3P, 10A, B Miniature Circuit Breaker

Catalogue Number: A9F53310
Acti 9 iC60H 3P 1A…63A Miniature Circuit Breaker
Retail
$478.68
RRP (Inc. GST)

Specifications

hide show
Range
Acti 9
Range of product
Acti 9
Product name
Disbo iC60
Product or component type
miniature circuit-breaker
Device short name
iC60H
Poles description
3P
Number of protected poles
3
[In] rated current
10 A
Network type
AC
Trip unit technology
thermal-magnetic
Curve code
B
Breaking capacity code
H
Breaking capacity
  • 10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • 42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
  • 20 kA Icu at 100...133 V DC conforming to EN/IEC 60947-2
    • Utilisation category
      category A conforming to EN/IEC 60947-2
      Network frequency
      50/60 Hz
      [Ue] rated operational voltage
      440 V AC 50/60 Hz
      Magnetic tripping limit
      4 x In +/- 20 %
      [Ics] rated service breaking capacity
    • 21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz
    • 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
    • 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
    • 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
    • 7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz
    • 20 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V DC
      • Limitation class
        3 conforming to EN/IEC 60947-2
        [Ui] rated insulation voltage
        500 V AC 50/60 Hz conforming to EN/IEC 60947-2
        [Uimp] rated impulse withstand voltage
        6 kV conforming to EN/IEC 60947-2
        Contact position indicator
        yes
        Control type
        toggle
        Local signalling
        trip indicator
        Mounting mode
        clip-on
        Mounting support
        rail
        Connection pitch
        9 mm pitches
        6
        Height
        85 mm
        Width
        54 mm
        Depth
        78.5 mm
        Net weight
        0.375 kg
        Mechanical durability
        20000 cycles
        Electrical durability
        10000 cycles
        Provision for padlocking
        padlockable
        Connections - terminals
      • single terminal (top or bottom) 1-25 mm² rigid
      • single terminal (top or bottom) 1-16 mm² flexible
        • Wire stripping length
          14 mm for top or bottom connection
          Tightening torque
          2-2 N.m top or bottom
          Earth-leakage protection
          separate block
          Compatibility code
          iC60
          Standards
        • EN/IEC 60898-1
        • EN/IEC 60947-2
          • IP degree of protection
            IP20 conforming to IEC 60529
            Pollution degree
            3 conforming to EN/IEC 60947-2
            Tropicalisation
            2 conforming to IEC 60068-1
            Relative humidity
            95-95 % at 55-55 °C
            Ambient air temperature for operation
            -35-70 °C
            Ambient air temperature for storage
            -40-85 °C
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            REACh free of SVHC
            Yes
            EU RoHS Directive
            Compliant
            Toxic heavy metal free
            Yes
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
             Pro-active China RoHS declaration (out of China RoHS legal scope)
            Environmental Disclosure
            ENVPEP1409009EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

            Frequently Asked Questions

            hide show

            What is the part number for 20A 10kA D curve 3 pole circuit breaker?

            The part number for 20A 10kA D curve 3 pole circuit breaker is A9F55320.

            What is the part number for a 3 phase, D-Curve, 50A breaker?

            The part number for a 3 phase, D-Curve, 50A breaker is a  - A9F55350.

            What is the part number for a 3 phase 10amp D-Curve RCBO?

            The part number for a 3 phase 10amp D-Curve RCBO is - A9F55310 & A9V02763

            For further information , visit link below:-
            https://www.schneider-electric.com.au/en/search/A9F55310
            https://www.schneider-electric.com.au/en/search/A9V02763

            What is the part number for a 6A B-Curve circuit breaker?

            The part name is A9F53106

            How can I make 1 Pole 10 Amps B Curve 30mA RCBO?

            To make 1 Pole 10 Amps B Curve 30mA RCBO, you need the following:
            A9F53110 - 1 Pole 10 Amps B Curve Breaker (https://www.schneider-electric.com.au/en/search/A9F53110)
            +
            A9V02663 - 2 Pole 30mA 63 Amps Add-on Vigi to suit 1 Pole iC60 Breakers (https://www.schneider-electric.com.au/en/search/A9F53110)

            Please note the total width of this combination will be equal to 3 Poles standard RCBO (3 x 18mm)

            What is the part number for 6A, B-curve, 3 pole, circuit breaker?

            The part number is A9F53306. This is a Acti 9 breaker.

            For further information please visit
            https://www.schneider-electric.com.au
             

            Do you have a C60H Circuit breaker single phase 10A?

            In the Schneider range we have the Acti 9 IC60H circuit breakers. The part number for a single phase, 10A is a A9F54110.

             

            What is the suitable vigi unit to suit with the A9F54332?

            A9F54332 is a 3 pole breaker.
            They have an option of having 3 pole vigi (A9V51363) or 4 pole vigi (A9V02763) for neutral conection .

            What is the part number for an A9D11810 but in "D" curve?

            need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
            for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
            and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
            User-added image    User-added image

            What is the part number for a 4 pole 50amp B-Curve C/B with Shunt release?

            The part number for a 4 pole 50amp B-Curve C/B with Shunt release is - A9F53450 & A9A26946

            for further information , visit links below:-
            https://www.schneider-electric.com.au/en/search/A9F53450
            https://www.schneider-electric.com.au/en/search/A9A26946
            User-added image

            What is the part number for a 3 phase 10amp RCBO?

            The part number for a 3 phase 10amp RCBO is - A9F44310 & A9V02763

            For further information , visit links below:-
            https://www.schneider-electric.com.au/en/search/A9F44310
            https://www.schneider-electric.com.au/en/search/A9V02763
            User-added image

            User-added image

            Data sheet for A9F54240 ?

            Data sheet attached