Quantcast

Acti 9 iDPN N Vigi, RCBO, 1P+N, 6A, C Curve, 6000A, 30mA, Type A

Acti 9 iDPN N Vigi, RCBO, 1P+N, 6A, C Curve, 6000A, 30mA, Type A

Acti 9 iDPN N Vigi, RCBO, 1P+N, 6A, C Curve, 6000A, 30mA, Type A

Item Number: A9D32606

Retail
$581.54
RRP (Inc. GST)

Product Dimensions

Width icon

Width36 mm

Height icon

Height85 mm

Depth icon

Depth73 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

iDPN Vigi

Range

Acti 9

Product or component type

residual current breaker with overcurrent protection (RCBO)

Device application

distribution

Market segment

  • residential
  • small commercial
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      [In] rated current

      6 A

      [Ue] rated operational voltage

      220...240 V AC 50 Hz

      Control type

      toggle

      Local signalling

      ON, OFF, fault trip

      Mounting mode

      clip-on

      Mounting support

      DIN rail

      Height

      85 mm

      Width

      36 mm

      Depth

      73 mm

      Net weight

      125 g

      Mechanical durability

      20000 cycles

      Electrical durability

      20000 cycles

      Connections - terminals

    • single terminal top or bottom 1-16 mm² rigid
    • single terminal top or bottom 1-10 mm² flexible
    • single terminal top or bottom 1-10 mm² flexible with ferrule
      • Wire stripping length

        15 mm for top or bottom connection

        Standards

        EN/IEC 61009-2-1

        Product certifications

      • VDE
      • KEMA
      • RCM
        • IP degree of protection

        • IP20 conforming to IEC 60529
        • IP40 (modular enclosure) conforming to IEC 60529
          • Relative humidity

            95-95 % at 55-55 °C

            Ambient air temperature for operation

            -25-60 °C

            Ambient air temperature for storage

            -40-85 °C

            REACh Regulation

            Free of Substances of Very High Concern above the threshold

            EU RoHS Directive

            Compliant

            Mercury free

            Yes

            RoHS exemption information

            Yes

            China RoHS Regulation

            Product out of China RoHS scope. Substance declaration for your information

            Environmental Disclosure

            ENVPEP111021EN

            Others

            Number of Units in Package 1

            1

            Number of Units in Package 2

            6

            Number of Units in Package 3

            54

            Package 1 Height

            4 cm

            Package 1 Length

            10 cm

            Package 1 width

            8 cm

            Package 2 Height

            10 cm

            Package 2 Length

            25.5 cm

            Package 2 width

            11 cm

            Package 3 Height

            30 cm

            Package 3 Length

            40 cm

            Package 3 width

            30 cm

            Unit Type of Package 1

            PCE

            Unit Type of Package 2

            BB1

            Unit Type of Package 3

            S03

            Product name

            Acti 9 iDPN Vigi

            Device short name

            iDPN N Vigi

            Poles description

            1P + N

            Number of protected poles

            1

            Neutral position

            left

            Network type

            AC

            Trip unit technology

            thermal-magnetic

            Curve code

            C

            Earth-leakage sensitivity

            30 mA

            Earth-leakage protection time delay

            instantaneous

            Earth-leakage protection class

            type A

            Breaking capacity

            6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1

            Suitability for isolation

            yes conforming to EN/IEC 60947-2

            Device location in system

            outgoer

            Network frequency

            50 Hz

            Magnetic tripping limit

            5...10 x In

            Residual current tripping technology

            voltage independent

            [Ics] rated service breaking capacity

            6000 A 100 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1

            Rated breaking and making capacity

            Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1

            Limitation class

            3 conforming to EN/IEC 61009-2-1

            [Ui] rated insulation voltage

            400 V AC 50 Hz

            [Uimp] rated impulse withstand voltage

            4 kV

            Contact position indicator

            yes

            Comb busbar and distribution block compatibility

            top or bottom: YES

            Connection pitch

            9 mm pitches

            4

            Locking options description

            padlocking device

            Tightening torque

            2-2 N.m top or bottom

            Earth-leakage protection

            integrated

            Compatibility code

            iDPN

            Pollution degree

            3

            Overvoltage category

            III conforming to IEC 60364

            Electromagnetic compatibility

            8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1

            Tropicalisation

            2 conforming to IEC 60068-1

            Package 1 Weight

            217 g

            Package 2 Weight

            1.366 kg

            Package 3 Weight

            12.842 kg

            WEEE

            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
            Show all specifications

            Frequently Asked Questions

            hide show

            What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

             
             

            A9D33620 = SI (Super Immunised)
            A9D32620 = Type A (AC or pulsating DC)

            Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
            Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
             

            What is the difference between the A9D73620 and A9D32620 RCBO's?

            The A9D73620 is the slimline RCBO which is the same rating and does the same as the A9D32620. It is just the physical size that is different.

            Where to find settings manual for MiCOM x3x Series?

            Issue 
            Need more information on settings on the MiCOM x3x.

            Product Line  
            MiCOM P13x
            MiCOM P23x
            MiCOM P43x
            MiCOM P53x
            MiCOM P63x

            Environment  
            Setting or Troubling settings

            Resolution    
            All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
            To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
            It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
            On the site download the P438 that is needed. 
             

            Will the Compact NSX breaker be for sale in the USA or Canada?

            Issue:
            Where can I buy a Compact NSX breaker?

            Product Line:
            Circuit Breakers

            Cause:
            This breaker is popular overseas and there is interest in the US

            Resolution:
            There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

            If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

            For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
            https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

            Why can't I purchase Schneider Electric US Lighting Control products any more?

            Issue:
            As of March 1, 2015 all US Lighting Control products (EXCEPT Powerlink and MVP panels) will enter their obsolescence phase and will no longer be purchasable for new orders. Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiative and concentrate our effort in new businesses with higher growth potential – Connected Home, Building Control in small buildings, and Electric Vehicle solutions.

            Product Line:
            All US Lighting Control product except Powerlink and MVP panels are affected. CBus, Occupancy Sensors, Low Voltage Switches, Relay Panels, Emergency Lighting Control Panels, Schneider Electric branded Current Limiting Panels, and Architectural Dimming Panels.

            Environment:
            US Lighting Control products

            Cause:
            Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiatives.

            Resolution:
            See cross reference sheet attached for available completive cross references.