iATL24 Impulse relay auxiliary

Acti 9 Iatl24 Control and Remote Indication With Ti24 Connector

Catalogue Number: A9C15424
iATL24 Impulse relay auxiliary
Retail
$305.26*
RRP (Inc. GST)

Specifications

hide show
Range of product
Acti 9
Range
Acti 9
Device short name
iATL24
Product or component type
control and indication auxiliary
Signal contacts composition
1 NO
Signalling circuit voltage
24 V DC: +/- 20 % 0.002...0.1 A
[Uc] control circuit voltage
  • 230 V AC 50/60 Hz impulse >= 200 ms
  • 24 V DC falling edge
  • 24 V DC rising edge
    • [Us] rated supply voltage
      230 V AC at 50/60 Hz
      Control type
      remote control
      [Ui] rated insulation voltage
      250 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      Maximum power consumption in W
      1 W
      Mounting mode
      fixed, on the left of CT
      Mounting support
      DIN rail
      Comb busbar and distribution block compatibility
    • bottom: YES
    • top: NO
      • Electrical durability
        250000 cycles conforming to IEC 60947-5-1
        Immunity to microbreaks
        10 ms
        Undervoltage behaviour
        no opening if loss of 24 V DC
        9 mm pitches
        2
        Height
        81 mm
        Width
        18 mm
        Depth
        68 mm
        Connections - terminals
      • power supply: tunnel type terminals 1 cable(s) 0.5-10 mm² - rigid
      • power supply: tunnel type terminals 1 cable(s) 0.5-6 mm² - flexible
      • power supply: tunnel type terminals 1 cable(s) 0.5-4 mm² - flexible with ferrule
      • input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² - rigid
      • input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² - flexible
      • input: tunnel type terminals 2 cable(s) 0.5-2.5 mm² - flexible with ferrule
      • Ti24 interface: spring-loaded terminal Ti24 2 cable(s) 0.5-1.5 mm² - rigid
      • Ti24 interface: spring-loaded terminal Ti24 1 cable(s) 0.5-1.5 mm² - flexible
        • Wire stripping length
        • power supply: 9 mm for bottom connection
        • input: 9 mm for bottom connection
        • Ti24 interface: 10 mm for top connection
          • Tightening torque
          • power supply: 1-1 N.m bottom
          • input: 1-1 N.m bottom
            • Range compatibility
            • Acti 9 iTL iTL
            • Acti 9 iTL iTLi
            • Acti 9 iTL iTLs
            • Acti 9 iTL iTLc
              • Product compatibility
              • Acti 9 Smartlink
              • iTL (32 A) - 230/240 V 50 Hz
              • iTL (16 A) - 230/240 V 50 Hz
                • Market segment
                  small commercial
                  Compatibility code
                  iATL24
                  Overvoltage category
                  IV
                  IP degree of protection
                • IP20 conforming to IEC 60529
                • IP40 (modular enclosure) conforming to IEC 60529
                  • Pollution degree
                    3 conforming to IEC 60439-1
                    Tropicalisation
                    2 conforming to IEC 60947-5-1
                    Relative humidity
                    93-93 % at 40-40 °C conforming to IEC 60068-2
                    Ambient air temperature for operation
                    -25-60 °C
                    Ambient air temperature for storage
                    -40-80 °C
                    Quality labels
                    CE
                    Standards
                    IEC 60947-1 appendix S
                    Sustainable offer status
                    Green Premium product
                    EU RoHS Directive
                    Compliant
                    Mercury free
                    Yes
                    RoHS exemption information
                    Yes
                    China RoHS Regulation
                    Product out of China RoHS scope. Substance declaration for your information
                    Environmental Disclosure
                    ENVPEP120425EN
                    Circularity Profile
                    ENVEOLI120411EN
                    WEEE
                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Warranty
                    18 months

                    Frequently Asked Questions

                    hide show

                    What is the replacement for Merlin Gerin 15322 ?

                    A9A15322

                    What is the Alternative for the Merlin Gerin 15913?

                    A9C15913

                    Data sheet for A9F54240 ?

                    Data sheet attached

                    Wanted to know if A9N18524 can be used as 3 pole breaker instead of 4 pole?

                    Yes, customer can use the 3 pole and leave 4 pole open.

                    What is the dimensions of the load shedding device A9C15906 ?

                    Height = 77 mm  Width = 145 mm Depth = 60 mm

                    What is the part number for a B curve 125A 3P breaker

                    The part number is A9N18426

                    What items come with the KITWALLBOX7?

                    A9Z51240 = Type B single phase RCCD
                    A9F54240 = 2 pole, 40A, Curve MCB
                    A9A26969 = Under voltage release

                    what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

                    Goals and Symptoms

                    what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

                    Facts and Changes

                    maximum current
                    R2 relay
                    soft start

                    Causes and Fixes


                    Characteristics of ATS48 relay :
                    max voltage : 400Vac (0.2A max)
                    thermal current : 5A
                    During life :
                    AC load
                    AC1 5A 250V 10E5 cycles (resistor)
                    AC15-14 : 0.5A (240Vac) 10E6 cycles (contactor)
                    Cos 0.5 1.8A (240Vac) 10E5 cycles (inductive)

                    DC load
                    DC13 : 0.5A (48Vdc) 10E6 cycles (contactor)
                    L/R 20mS 1.8A (30Vdc) 10E5 cycles (inductive)
                    minima commutation capacities :
                    6Vdc 10mA 10E7 cycles (PLC low level)

                    It's availble for all range.


                    Legacy KB System (APS) Data: RESL156323 V4.0, Originally authored by on , Last Edited by on
                    Related ranges: Altistart 48