iATLc+c multi-level centralized control auxiliary

Acti 9 Multi Level Centralized Control iATLc+c, 24...240VAC

Catalogue Number: A9C15410
iATLc+c multi-level centralized control auxiliary
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
Acti 9
Range
Acti 9
Device short name
iATLc+c
Product or component type
multilevel centralized control auxiliary
[Uc] control circuit voltage
24...240 V AC 50/60 Hz impulse
[Ui] rated insulation voltage
440 V
[Uimp] rated impulse withstand voltage
Remote control type
2 entries for switch
Mounting mode
fixed
Mounting support
DIN rail
9 mm pitches
2
Height
86 mm
Width
18 mm
Depth
71 mm
Connections - terminals
  • tunnel type terminals0.5-4 mm² - rigid
  • tunnel type terminals0.5-4 mm² - rigid - with cable end
  • tunnel type terminals1-4 mm² - flexible
  • tunnel type terminals1-4 mm² - flexible - with cable end
    • Wire stripping length
      11 mm
      Tightening torque
      1-1 N.m
      Range compatibility
    • Acti 9 iTL iTLc
    • Acti 9 iTL iATLc
    • Acti 9 iTL iATLc+s
      • Market segment
      • residential
      • small commercial
        • Compatibility code
          iATLc+c
          Overvoltage category
          III
          IP degree of protection
          IP20 conforming to IEC 60529
          Tropicalisation
          2
          Relative humidity
          95-95 % at 55-55 °C
          Ambient air temperature for operation
          -20-50 °C
          Ambient air temperature for storage
          -40-70 °C
          Standards
          EN/IEC 60669-2-2
          Sustainable offer status
          Green Premium product
          REACh Regulation
          Free of Substances of Very High Concern above the threshold
          REACh free of SVHC
          Yes
          EU RoHS Directive
          Compliant
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
          Product out of China RoHS scope. Substance declaration for your information
          Environmental Disclosure
          ENVPEP110302EN
          WEEE
          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
          Warranty
          18 months

          Documents & downloads

          hide show

          Frequently Asked Questions

          hide show

          What is the Alternative for the Merlin Gerin 15913?

          A9C15913

          What is the part number for an A9D11810 but in "D" curve?

          need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
          for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
          and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
          User-added image    User-added image

          How wide is A9A15219 Safety Transformer ?

          10 Modules of 9mm = 90mm 

          What is the code for 10A 2P D Curve MCB - rated at 10kA ?

          Code = A9F45210   C60 MCB 

          what is size of the Cable that will fit into the MCB A9F54106 ?

          Cable = 25mm stranded
           

          What is the code for 4 pole 10kA 50A D curve MCB?

          Code = A9f55450  (iC60H) 

          What is the alternative to the 4RCBE210/30?

          Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

          What is the dimensions of the load shedding device A9C15906 ?

          Height = 77 mm  Width = 145 mm Depth = 60 mm

          What is the part number for a 3 phase 10amp D-Curve RCBO?

          The part number for a 3 phase 10amp D-Curve RCBO is - A9F55310 & A9V02763

          For further information , visit link below:-
          https://www.schneider-electric.com.au/en/search/A9F55310
          https://www.schneider-electric.com.au/en/search/A9V02763

          Do you have a C60H Circuit breaker single phase 10A?

          In the Schneider range we have the Acti 9 IC60H circuit breakers. The part number for a single phase, 10A is a A9F54110.

           

          what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

          Goals and Symptoms

          what is the maximum current for the R2 relay contacts on all sizes of ATS48 range of soft start

          Facts and Changes

          maximum current
          R2 relay
          soft start

          Causes and Fixes


          Characteristics of ATS48 relay :
          max voltage : 400Vac (0.2A max)
          thermal current : 5A
          During life :
          AC load
          AC1 5A 250V 10E5 cycles (resistor)
          AC15-14 : 0.5A (240Vac) 10E6 cycles (contactor)
          Cos 0.5 1.8A (240Vac) 10E5 cycles (inductive)

          DC load
          DC13 : 0.5A (48Vdc) 10E6 cycles (contactor)
          L/R 20mS 1.8A (30Vdc) 10E5 cycles (inductive)
          minima commutation capacities :
          6Vdc 10mA 10E7 cycles (PLC low level)

          It's availble for all range.