block mtg trunking rnd surf

Block MTG TRUNKING RND SURF

Catalogue Number: 900RMB
block mtg trunking rnd surf
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Sustainable offer status
Green Premium product
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
ENVPEP100802EN

Frequently Asked Questions

hide show

What size Duct Entry does the 900RMB have?

It has 2x 25x16mm entries (one at each end).

Does the Clipsal 900 RMB have a lid?

The 900RMB is a mounting block for round surface sockets. It does not have a lid as it is not designed as a junction box.

What is the replacement for a 970RM?

The closest alternative for a 970RM is a 940RMT/1.

Does Clipsal have a sweep fan with 900mm, stainless steel blades?

No we only have the white, aluminium blades in 900mm - 3HS900AL-WE.

Is the 900MBC available in New Zealand

 No longer available in NZ

What size entry(s) does the 900SPMB have?

The 900SPMB has four 25 mm x 16 mm trunking entries, one at each side and end.

What is the replacement to the 970RM?

940RMT/1

Does the 900spmb come in black?

No, the 900SPMB comes in White Electric, Grey and Brown.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900SPMB

What is the replacement for a 9001TB contact block?

Issue:
Cross for a 9001TB contact block?

Product Line:
Push Buttons and Operator Interface

Environment:
9001K Push Button 

Resolution:
Replace with a 9001TAD1 liner and (2) 9001KA1 contact blocks.
Note that the 9001TAD1 is obsolete. The entire operator will need to be crossed to the 9001K line of pushbuttons.

Is the 900TCB Still Available?

 now obsolete and there is no direct replacement.

What does the 16A & 6AX mean on the 600RM?

It means the relay module can switch a load of up to 16A resistive or a 6A fluorescent load.

What is the material of the plunger for 9007MS limit switch?

Issue:
9007MS plunger head material

Product Line:
Class 9007 Encapsulated Miniature

Environment:
9007MS/ML Miniature

Resolution:
The plunger is made of steel.

9007MS Limit can the 4 or 5 pin connector be added in the field?

Issue:
Field install for 9007MS/ML pin connector

Product Line:
Encapsulated Miniature

Environment:
9007MS/ML Miniature

Resolution:
9007MS are encapuslated (sealed) switches.  Connectors can not be field installed.

Can the EGX400 or ECC21 fiber port connect directly to a gigabit (1000 Mb) network?

Issue:
User would like to communicate with an EGX400 or ECC21 using a gigabit (1000 Mb) fiber network
 
Product line:
ECC21, EGX400
 
Cause:
Customer wanted to know if they can directly connect 1000Mb a gigabit) fiber connection to EGX400 or ECC21 fiber port?
 
Resolution:
Customer cannot connect a 1000Mb fiber connection directly to the ECC21 or EGX400.
As per the ECC21 and EGX400 Installation Manuals, the fiber port is compatible with 100Mb networks only.
If gigabit fiber network connections are needed, a 100Mb multi-mode LC fiber converter will be required. 

Alternately, a gigabit fiber switch with 10/100/1000 copper ethernet connections could be used. In this instance, the fiber would be run to the switch and 10/100 ethernet to the EGX or ECC gateway.
 

Travel distance for plunger style 9007MS limit switches

Issue:
What is the travel distance for 9007MS plunger limit switches

Product Line:
9007MS Limit Switches

Environment:
NEMA Limit Switches

Cause:
Travel distance is an important consideration for selecting limit switches for certain

Resolution:
The travel distance to engage the contacts is 0.07" and the dstance to reset the contacts is 0.004" in the opposite direction.  Total travel for these switches is limited to 0.19" and any movement beyond this distance could damage the switch.
 

Does Clipsal do a 900mm version of the MDECLGML600100?

No, we don't do a 900mm version of the MDECLGML600100.

What is the part number for the replacement surge arrester for the 970RMT?

The part number for the replacement surge arrester for the 970RMT is - 940RMT/1

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=940RMT/1

Does Schneider Electric offer a 9007 type limit switch in stainless steel?

Issue:
Does Schneider Electric offer a 9007 type limit switch in stainless steel?

Product Line:
Limit Switch

Environment:
9007

Cause:
Product feature

Resolution:
Schneider Electric does not offer stainless steel limit switches.

What is the length of cable on a VW3A5203

 The cable length is 900mm

Do you have a fan in stainless steel with 900mm blades?

No unfortunately we do not have anything of that description. However, we do have a white aluminum fan with 900mm blades. The part number is 3HS900AL-WE.

Does 9007CR53B2 include the 9007B head?

Issue:
Is the 9007B head included in the full part number 9007CR53B2?

Product Line:
9007C Limit Switches

Environment:
9007CR53B2

Resolution:
Yes, it does.
 

What is the part number for the replacement cartridge for the 970RM surge arrester?

The part number for the replacement cartridge for the 970RM surge arrester is - 970PM
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=970PM
User-added image

What are the contact ratings of the 9007MS/ML type limit switch?

Issue:
Needs to know the contact ratings of a 9007MS/ML limitswitch.

Product Line:
9007MS, 9007ML Limit Switch

Environment:
9007MS/ML

Resolution:
These limit switches have contact ratings of 300V AC and DC, at up to 10 amperes. Contact ratings may be higher than connector ratings
when using some of the prewired connector products.
 

What is the fluro rating for a PDL 600RM

Fluro rating is 6AX

9001B Three Button Control Station in NEMA 3R

Issue:
Is there a NEMA 3R version of the 9001B Control Stations with 3 buttons

Product Line:
9001B Control Stations

Environment:
US Product

Cause:
There are NEMA 3R versions of the one and two button stations listed, but of the three button stations

Resolution:
There is no NEMA 3R three button 9001B control station.  The 9001KY/9001SKY may be a suitable alternative.

What is the replacement for a PDL 648T15

Replacement part numbers PDL 648TM + PDL 600RM

What is the replacement for a PDL 556

Use PDL 100MPIR + PDL 600RM relay

Do PDL do a relay mech

Yes, it is a PDL 600RM with a 16A resistive rating

Can the PDL 600RM be used with metal halide lamps

No use a industrial relay or contactor

What is the load rating for a PDL 600RM relay

6AX = 6amp reactive load, or 16A resistive loads.

Do you have a 45RU data cabinet 800mm Wide X 1000mm Deep?

Yes, the part number is 3106N45C810-BK.

What is the part number of the surface mounting box that has a duct entry?

The part number of the surface mounting box that can accept a duct is 900SPMB. The 900SPMB is a standard pattern Surface Mounting Box for single gang accessories. Internal depth - 33mm.
Features: 4 - 25 x 16mm Trunking Entries, including one each end and side.
Supplied with 3 - Cat. No. 900MBC Clip-in/ push out caps, 4 - Cat. No. 220/10 Insulating Caps and 2 - M3.5 x 0.8 x 16mm long pan head screws. Screws thread into brass inserts.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=900SPMB

 

What is the description for part number 3042653253?

Issue:
What is a 3042653253?

Product Line:
9001B control stations

Environment:
US Product

Cause:
Non standard replacement part

Resolution:
3042653253 is a toggle switch in a Type NEMA 7 and Type NEMA 9, Class 9001B control station. 
These control stations were obsoleted in 1994 along with all component parts.

What is replacement part number for the box only for 9001BR204?

Issue:
9001BR station replacement parts

Product Line:
Class 9001B Control Stations and Enclosures

Environment:
9001B Standard Duty Control Stations

Resolution:
Replacement enclosure parts (including the case or the cover) are not available for 9001BR devices.

Can a 648TM be used to switch a 100W electronic transformer

Need to use a 600RM controlled by the 648TM

Can I run more than 3A through a PDL 648TM

No, you need to add a relay part number PDL 600RM or contactor

What is the inductive load for a PDL 648TM

There is no inductive load.  Need to use a PDL 600RM as well.

What replaces the PDL 556 PIR sensor

Use the PDL 100MPIR + 600RM if required to switch higher loads

Can I use the PDL 648TM timer to run a bathroom heater

You need to use a 600RM with it and it should be fine

what is the replacement part for a 970rm ?

 
 
 
 
the 970rm has been replaced by the 940rmt/1

Does the 800 series intermediate mech come in a larger than S2 size

No, only available in the S2 size PDL882M10N
However we can make any 2 way switch into an intermediate switch with the use of a 600RM relay and drop the 600Rm inside the flush box

 

Do we have explosion proof start-stop control stations?

Issue:
Do we have explosion proof start-stop control stations?

Product Line:
30mm Control Stations and Enclosures      
             
Environment:
9001B Standard Duty Control Stations

Cause:
Verifying that Schneider Electric has an offering for this application.        
   
Resolution:
The 9001BR control station are rated Nema 7 and 9 for hazardous locations.

Can the 9001BR103 come with a normally open contact?

Issue:
Customer wants the 9001BR103 except with a normally open contact.

Product Line:
30mm Control Stations  

Environment:
9001B Standard Duty Control Stations

Cause:
Application is calling out for a normally open contacts

Resolution:
Order both replacement contact block assembly and the terminal block wiring recepticle assembly.   9001BOC107 and the 9001BFB107.  This will give a NO and a NC contact.

What PDL sensor can I use for turning a toilet light on upon entry

Use PDL 100MPIR + PDL 600RM both mounted in a PDL 682VH plate

Does the 546 universal timer have an inbuilt override

This does not have a manual override, you would need to use the 648TM with a 600RM in order to get that functionality

Can the 681MT16 be used for two way switching?

Yes it can, but if 3 way switching is required, please use an additional 600RM relay. (see install sheet for wiring diagram)

Can a PDL 100MPIR be used with LED lighting?

No, but the 600RM relay module can be used in conjunction with the 100MPIR to switch the LED lighting.

Will the PDL100MPIR switch LED lighting?

No, Suggest using the 600RM intermediate relay.
https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=1865

 

Can I break the 9007C62B2 into components?

Issue:
Needs to break down limit switch into component parts.

Product Line:
US Limit Switches / 9007C62B2

Environment:
United States

Cause:
To obtain replacement parts or order from components when no stock on assembled catalog number.

Resolution:
Yes. Order the 9007B head, the 9007CO62 plug in unit, and the 9007CT62 plug in receptacle. These three components make up the 9007C62B2. Order lever separately.

Can the 9001B129 be field engraved?

Issue:
Checking if the 9001B129 can be field engrave.

Product Line:
9001B Legend Plate

Environment:
9001B129

Resolution:
No. These units are hot stamped.
 
Show More