socket outlet vert shaver

Universal Shaver Socket Outlet, 240/110VAC, Vertical

Catalogue Number: 727V
socket outlet vert shaver
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Mounting position
vertical
Fixing mode
by screws
Local signalling
without light indicator
[Ue] rated operational voltage
110/240 V AC
Depth
18 mm
Length
184 mm
Width
85 mm
Fixing center
152 mm
Standards
  • AS/NZS 3100
  • AS/NZS 3112
  • AS/NZS 3133:approval number S/1
    • Sustainable offer status
      Green Premium product
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      Frequently Asked Questions

      hide show

      Is there a shaver outlet with a GPO on the same plate?

      Yes there are a few variations of the 727. Just use the search engine at Clipsal.com to find the one to suit your needs.

      Do we sell bushings as spare parts on the Altistart ATS23, customer has melted theirs?

      Issue:   Do we sell bushings as spare parts on the Altistart ATS23, customer has melted theirs?
       
      Product Line:   ATS23
       
      Environment:  All
       
      Cause:   Replacement parts
       
      Resolution:   There are no parts available for the ATS23


       

      How can you obtain the wiring harness for an Altistart ATS23 that goes to the terminal block?

      Issue:   How can you obtain the wiring harness for an Altistart ATS23 that goes to the terminal block?
       
      Product Line:   ATS23
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   That was not sold as a spare part  No parts available


       

      Should the Altistart ATS23 wired in a delta or wye configuration?

      Issue:   Should the Altistart ATS23 wired in a delta or wye configuration?
       
      Product Line:   ATS23
       
      Environment:  All
       
      Cause:   N/A
       
      Resolution:   
      A grounded delta would work. A wye connection only provides 58 % voltage and an open delta configuration could cause either overload conditions or phase faults.


       

      Can the ZB2BE101 contact block be used with ZB4 operators?

      Issue:
      Can the ZB2BE101 contact block be used with ZB4 operators?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      No. The mounting styles are incompatible. The ZB2BE contact blocks are screw mounted to mounting collar and the ZB4 contact blocks clip on the mounting collar with spring loaded clip.

       

      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

      Issue:
      Identifying replacement coils for tesys D non-reversing and reversing conactors

      Product Line:
      IEC Contactors and Starters

      Environment:
      Products sold and used in the United States

      Cause:
      Replacement coil is needed

      Resolution:
      DC replacement coils are not available.
      AC Coils are 50/60 hertz for voltages as listed below:

      Volts - Part Number
      12 ____ LXD1J7
      21 ____ LXD1Z7
      24 ____ LXD1B7
      32 ____ LXD1C7
      36 ____ LXD1CC7
      42 ____ LXD1D7
      48 ____ LXD1E7
      60 ____ LXD1EE7
      100 ___ LXD1K7 ( never brought to North America )
      110 ___ LXD1F7
      115 ___ LXD1FE7
      120 ___ LXD1G7
      127 ___ LXD1FC7
      200 ___ LXD1L7
      208 ___ LXD1LE7
      220 ___ LXD1M7
      230 ___ LXD1P7
      240 ___ LXD1U7
      277 ___ LXD1W7
      380 ___ LXD1Q7
      400 ___ LXD1V7
      415 ___ LXD1N7
      440 ___ LXD1R7
      480 ___ LXD1T7
      575 ___ LXD1SC7
      600 ___ LXD1X7
      690 ___ LXD1Y7


      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

      Different Types of UPS Systems

      Executive Summary

      There is much confusion in the marketplace about the different types of UPS systems and their characteristics. Each of these UPS types is defined, practical applications of each are discussed, and advantages and disadvantages are listed. With this information, an educated decision can be made as to the appropriate UPS topology for a given need.

      Introduction

      The varied types of uninterruptible power supplies (UPS) and their attributes often cause confusion in the data center industry. For example, it is widely believed that there are only two types of UPS systems, namely standby UPS and on-line UPS. These two commonly used terms do not correctly describe many of the UPS systems available. Many misunderstandings about UPS systems are cleared up when the different types of UPS topologies are properly identified. UPS topology indicates the basic nature of the UPS design. Various vendors routinely produce models with similar designs, or topologies, but with very different performance characteristics.

      UPS types

      A variety of design approaches are used to implement UPS systems, each with distinct performance characteristics. The most common design approaches are as follows:

      • Standby
      • Line Interactive
      • Standby-Ferro
      • Double Conversion On-Line
      • Delta Conversion On-Line


      Continue reading the APC White Paper, "The Different Types of UPS Systems"  which discusses this topic in detail.