Mains Connection Boxes, Mains Connection Boxes - Fused, 80A Single Phase

Mains Connection Boxes, Mains Connection Boxes - Fused, 80A Single Phase

Mains Connection Boxes, Mains Connection Boxes - Fused, 80A Single Phase

Item Number: 651A-BK

Retail
$468.68
RRP (Inc. GST)
Colour Black (BK)
  • Black 1 PCE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Physical

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

1045 g

Package 1 Height

10 mm

Package 1 width

10 mm

Package 1 Length

154 mm
Show all specifications

Frequently Asked Questions

hide show

What is the standard mains fuse box?

The standard mains fuse box is 651A

Do you do the cover for a mains fuse box 651A?

Yes the part number for a cover for a mains fuse box 651A is 651A-COVER-BK.

What is the part number for the Fuse unit for 651A3-BK

651A-CARRIER
for more information on the 651A series please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=651a

Are there any metal finish cover plates available for the PDL 651?

Yes, the PDL 682 coverplate is the same one used for the PDL 651. The metal cover plates are available in Polished Brass (PB), Brushed Bronze (BBZ) and Stainless Steel (SS).
Code example (PDL 651 coverplate in Polished Brass): PDL 682MPB

Is there a cover to suit a mains connection box 651A available as a spare part?

Yes, the Part number is 651A-COVER

​Can you purchase the cover for the 651A on its own?

Yes, you can the part number for the cover is 651A-COVER-BK

What is the part number for a 65kA, single phase, surge arrestor?

The part number for a 65kA surge arrestor is a - A9L65101.

Do our LC1D09 to 65A contactors come with NO & NC aux contacts

 Yes they come with both and they are rated at 10A 

What are the control power requirements for the Enercept Network Adapter (ENA)?

Issue
What are the control power requirements for the ENA?

Product Line
Enercept Meter, ENA

Cause
User would like to know control power range for ENA

Environment
Installing ENA

Resolution 
The control power requirements for the ENA (Enercept Network Adapter) are as follows: 9-30Vdc or 12-24Vac ; not including power factor, 1.5W max, 125mA max @12Vdc, 65mA max @24Vdc.

 

What is the replacement for the Tesys D Contactor LC1D65U7?

use the new code - LC1D65AU7
3P EVERLINK CONTACTOR 65A 30kW AC3 240VAC
See link for Data Sheet:
https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D65AU7

How much power is dissipated by the high end Quantum PLCs?

This can be calculated as Bus Current * Bus Voltage.

140 CPU 651 50 -> 2160mA * 5V = 10.8W
140 CPU 651 60 -> 2760mA * 5V = 13.8W

140 CPU 651 60S-> 2760mA * 5V = 13.8W
140 CPU 652 60 -> 2760mA * 5V = 13.8W
140 CPU 658 60 -> 2760mA * 5V = 13.8W

140 CPU 670 60 -> 2500mA * 5V = 12.5W
140 CPU 671 60 -> 2500mA * 5V = 12.5W
140 CPU 671 60S-> 2500mA * 5V = 12.5W

140 CPU 672 60 -> 2500mA * 5V = 12.5W
140 CPU 672 61 -> 2500mA * 5V = 12.5W

140 CPU 678 61 -> 2500mA * 5V = 12.5W

To calculate BTU you can take the wattage and multiply it by 3.4144.

What is the largest amperage D Line IEC contactor that can accomodate spring terminals, using a ``3`` after the amperage in the part number, such as an LC1D123G7?

The ``3`` form for spring terminals is available on 65A and below IEC contactors. On the 40, 50 and 65 amp devices the spring terminals are on the control circuit only. It is not available on 80A, 115A or 150A D Line contactors.