WPS_2G flush surround
surr flush 2g 56 series
WPS_2G flush surround
surr flush 2g 56 series

Flush SurRound, 2 Gang

Catalogue Number: 56FA2
WPS_2G flush surround
surr flush 2g 56 series
WPS_2G flush surround
surr flush 2g 56 series
Colour: Grey
Colour: Per UOM Std.
  • Chemical Grey 1 PCE
  • Grey 1 PCE
  • Resistant Orange 1 PCE
  • Resistant White Electric 1 PCE
  • Woolworths Grey 1 PCE
Added to cart

Specifications

hide show
Range
Clipsal - 56 Series
Range of product
Series 56
Product brand
Clipsal
Product or component type
cover frame
Colour code
RAL 7035
Material
polycarbonate: housing
Mounting position
horizontal and vertical
Device mounting
surface
Material
PVC (polyvinyl chloride)
Mounting mode
wall-mounted
Type of installation
indoor
Depth
13 mm
Length
157 mm
Width
254 mm
Height
157 mm
Net weight
0.212 kg
Ambient air temperature for operation
-25-75 °C
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Product Environmental

  • Operating Manuals

  • Specifications

  • Certificates (MSDS)

  • Corporate Marketing

Frequently Asked Questions

hide show

What is the part number of the flush surround to suit 56CV, one piece cover, switched outlets?

56FA2 is the part number of the flush surround to suit 56CV, one piece cover switched outlets. Surface mounted 56 Series Sockets, Switches and Combinations can be transformed into flush mounting equivalents using the 56FA Surrounds and Brackets. The surrounds can be used on various types of walls to ensure a neat installation, such as:
• a mounting enclosure (back box) in poured concrete
• a bracket on brick, brick veneer or panel walls.
The brackets provide the installer with a  practical method of flush mounting 56 Series accessories. Comprehensive installation instructions are supplied with all units.
56FA1, 56FA2, 56FA3 and 56FA4 Flush Surrounds contain a moulded flange, foam gasket and stainless steel mounting screws.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2

What is the 56 Series box for flush mounting PDL 56E2 enclosure

 PDL 56FA2

Does the PDL 56FA2 come with a flush box

No, it comes with a gasket and metal mounting plate to fix to the surface to make the switch / socket flush

What comes with a PDL 56FA1

The PDL 56FA1 comes with Mounting flange, Foam sealing gasket, mounting plate, and necessary screws

What is the cut-out for the 56FA flush mount surround?

Solid and Cavity Brick Walls (Bracket Mounting)

Prepare wall by cutting hole 90 x 90mm for 56FA1, 90 x 190mm
for 56FA2, 90 x 285mm for 56FA3 and 190mm2 for 56FA4.
Mount bracket to exterior wall using any suitable fixing device i.e.
thrubolts, fibre plugs, etc.
Remove adhesive backing sheet from gasket and adhere to inner
surface of flange. Mount modules to bracket through flange.
Note: 1. For soft or porous brickwork we suggest adhesive
anchored fixing.
2. When mounting to brick ensure all mortar joints are
sealed with suitable caulking compound.

 

Panel Type Walls (Bracket Mounting)

Prepare wall by cutting hole as described above for solid and
cavity brick walls. Mount bracket to wall using suitable hollow wall
anchors. Adhere gasket to flange and mount modules through
flange to bracket.
Note: If possible mount bracket to building frame i.e. wooden
noggins and studs with suitable wood screws.

Does the flush surround 56FA2 work with the Easy 56 Series as well as the standard 56 Series?

Yes the flush surround 56FA2 does work with the Easy 56 Series as well as the standard 56 Series?
Some of the key features are:
  • Enclosures and Boxes
  • Flush surround suits 2 Gang 56 Series (157 x 254mm).
  • Temperature range -25C to +75C.
For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2


 

What is the part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base??

The part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base is - 56FA2 & 56FA2B
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56FA2
https://www.clipsal.com/Trade/search-results?q=56FA2B

User-added image
User-added image

What is the part number for flush surround for mounting 56SW320?

The part number for flush surround for mounting 56SW320 is - 56FA1 & 56FA1B

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56FA1

User-added image

What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

Product Line:
Circuit Breakers

Environment:
Electrical Distribution Equipment

Resolution:
The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

Is part number 56/32 pad lockable?

Yes part number 56/32 can be pad lockable.

Does the bridge for PDL 56PE2 come with the product

 Yes it does

Can you buy a 56PB2 without a lable

No

What is the cap for a 56CSC310?

56SC2

Is the 563L2 still available?

Yes, the 563L2 is still part of our range.

Some of the key features are:
  • 3 cables
  • Grey insulated
  • Extended

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=563L2





 

Is part number 56/32 available in single gang?

No. Unfortunately, part number is not available as single.

Can I get a 56JB2 with a clear lid?

No, but you can get a clear lid separately.
The part number is 56L2-TR.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56L2

Do you do a 56/32 with one spot for a 30 mech not two?

No unfortunately we dont make that part you would need to place a 30P to fill one of the holes.

What is the part number for a lid/cover for the 56ES2?

The part number for a lid/cover for the 56ES2 is - 56L2
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56L2
User-added image

Is there one gang vesion of 56/32 adaptable enclosure to take 30 series mechanisms?

Unfortunately not. We do not have one gang version of 56/32. The unused gang can be blanked off using 30P, blanking mechanism.
For further information, please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=56/32
https://www.clipsal.com/Trade/Products/ProductDetail?catno=30P

Can a 56PB2 be mounted horizontally (face up) in a wet area?

It is not recommended if there is another option as the IP66 rating doesn't allow for immersion in water, which is what happens if water pools in the lid.

What is the part number for a 56C310 with a deep base?

The part number for a 56C310 with deep base is - 56ED2 & 56C310LE

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56ED2
https://www.clipsal.com/Trade/search-results?q=56C310LE
User-added image

What IP66 enclosure can be used for 30 series mechs?

Part no 56/32 has IP66 rating and can be used for

30 series mechs

What is the operating temperature of the 563/1 and the 563/2 1 and 2 screw bluepoints?

Our connectors are made of Polypropylene (which is a flame retardant material) according to the supplier this material can hold up top +-165C.
Although I will not recommend more than room temperature + 40C.
Keep in mind cables will not stand such temperature anyway as they normally rated between 75C to 90C

Some of the key features are:
  • Cable Connectors
  • Single or double screw
  • Clear insulated
  • Suits up to 2 x 6mm² cables


 

How are the Color Codes 568A and 568B different?

Issue:
The difference between T568A and T568B color codes is needed.

Product Line:
Cables and Connectivity Solutions, Patch Panels

Environment:
CAT6PNL-24 and CAT6PNL-48, all serial ranges. 

Cause:
Not following the correct color code can cause wiring errors.

Answer: 
568A and 568B are color code standards that show which color wire matches up with a specific position on an RJ45 connector. When designing a network infrastructure only one color code can be followed. All commercial and residential wiring in the US follows TIA 568B color code. Some Federal agencies had historically followed 568A, but many have changed to 568B. 

T568B Color Code
RJ45 Pin---Pair Color
1-------------White/Orange
2-------------Orange
3-------------White/Green
4-------------Blue
5-------------White/Blue
6-------------Green
7-------------White/Brown
8-------------Brown

T568A Color Code
RJ45 Pin---Pair Color
1-------------White/Green
2-------------Green
3-------------White/Orange
4-------------Blue
5-------------White/Blue
6-------------Orange
7-------------White/Brown
8-------------Brown

Are APC Cat 6 Patch Panels color coded for 568B or 568A?

Issue: 
The installer needs to know the color code on the rear of the Cat 6 patch panel.  
 
Product Line:
Cables and Connectivity Solutions, Patch Panels
 
Environment:
CAT6PNL-24, CAT6PNL-48
 
Cause:
Installers need to know if the patch panel has the color code they require.
 
Resolution : 
 
The CAT6PNL-xx series of Patch Panels have both 568B and 568A color codes. Cat 5e, 6 and 6a patch cables and other cabling accessories can be viewed at www.apccables.com 

How do you read the color code on the IDC connectors of the Cat 6 Patch Panels?

Issue:
Customers may question which color code instructions to follow, 568B vs. 568A. Or they may not understand how to read the color code.

Product Line:
Cables and Connectivity Solutions, Cat 6 Patch Panels

Environment:
All versions and serial ranges.

Cause:
The color code instructions may be confusing.

Resolution:
For high speed networking 568B is used almost universally.
If you need help determining how to terminate to the 568B or 568A color code please see the attached file.
 

What is the part number for Saturn ZEN series two gang plate with Cat6 data mechanisms?

Saturn ZEN series two gang plate with Cat6 data mechanisms can be built using the below part numbers:
Z4032VH - Grid and Plate Assembly 2 Gang Saturn ZEN
+
2 off 30RJ45SMA6 - 30 Series Cat6 UTP Connector Mechanisms, Modular socket, 568A, RJ45.

For further information, please visit the below links:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=Z4032VH

https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SMA6

What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (US only)?

The CAGE codes for Schneider Electric/SQUARE D are listed below:
CAGE Code Company Address
04429 SQUARE D CO LEEDS MFG PLANT 940 MOORE ST NE LEEDS, AL 35094
05684 SQUARE D CO MIDDLETOWN MFG PLANT 1500 S UNIVERSITY BLVD MIDDLETOWN, OH 45044
07442 SQUARE D CO DALLAS ASSEMBLY PLANT 1111 REGAL ROW DALLAS, TX 7524
12670 SQUARE D COELECTROMAGNETIC INDUSTRIES DIV 1410 DONALDSON PIKE B-5 NASHVILLE, TN 37217
14280 SQUARE D CO LEXINGTON MFG PLANT 1601 MERCER RD LEXINGTON, KY 40511
14799 SQUARE D CO CHICAGO ASSEMBLY PLANT 9522 W WINONA SCHILLER PARK, IL 60176
19804 SQUARE D CO GRAND BAY OF BRECKSVILLE 6995 S EDGERTON RD SUITE 100 BRECKSVILLE, OH 44141
2E203 SQUARE D CO 810 GLEN EAGLE CT SUITE 100 BALTIMORE, MD 21286
4T466 SQUARE D CO 1010 AIRPARK CENTER DR NASHVILLE, TN 37217
51917 SQUARE D CO ASHEVILLE MFG PLANT 128 BINGHAM RD ASHEVILLE, NC 28806
51918 SQUARE D CO AUTOMATION AND CONTROL BUSINESS RALEIGH, NC 27611
51920 SQUARE D CO COLUMBIA MFG PLANT SUMTER HWY 76 AND 378 COLUMBIA, SC 29209
55947 SQUARE D CO SORGEL MFG PLANT 4065 N RICHARDS ST MILWAUKEE, WI 53212
56158 SQUARE D CO OSHKOSH MFG PLANT 3300 MEDALIST DR OSHKOSH, WI 54901
56302 SQUARE D CO CEDAR RAPIDS MFG PLANT 3700 6TH ST SW CEDAR RAPIDS, IA 52406
56303 SQUARE D CO 1717 CENTER PARK RD LINCOLN, NE 68512
56304 SQUARE D CO OXFORD MFG PLANT 5735 COLLEGE CORNER RD OXFORD, OH 45056
56365 SQUARE D CO CORPORATE OFFICES 1415 S ROSELLE RD PALATINE, IL 60067
63637 SQUARE D CO MISSOURI MFG PLANT 4800 PARIS RD COLUMBIA, MO 65202
63831 SQUARE D CO HUNTINGTON PLANT 6 COMMERCIAL RD HUNTINGTON, IN 46750
70745 SQUARE D CO SENECA PLANT 1990 SANDIFER BLVD SENECA, SC 29678
88434 SQUARE D CO 13191 CROSSROADS PKY N SUITE 205 LA PUENTE, CA 91746
88753 SQUARE D CO 3516 CONCORD RD YORK, PA 17402


Legacy KB System (APS) Data: RESL206488 V1.0, Originally authored by MaTh on 10/26/2011, Last Edited by MaTh on 10/26/2011
Related ranges: Standards Applied to Power Management PRODUCTS

Do we make a 56DB2 backet as a spare part?

Unfortunately we do not to this as a spare part. However, it can be ordered as a special.

Use the order code GCR_56_MISC

The part number is 56DB2PANEL