c-bus-dmx one way gateway

C-Bus to DMX One Way Gateway, DIN Rail Mount, 4M Modules, 300Mm Interface Cable

Catalogue Number: 5500DMX
c-bus-dmx one way gateway
Retail
$1,033.79
RRP (Inc. GST)

Specifications

hide show
Range of product
C-Bus
Range
C-Bus
Product brand
Clipsal
Product or component type
gateway
Device application
communication
Number of modules
4
Local signalling
LED
Mounting support
DIN rail
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
X

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Specifications

  • Application Solutions

  • Corporate Marketing

  • Software - Released

Frequently Asked Questions

hide show

What are the maximum number of mappings available in 5500DMX?

There are 12 mappings, each mapping can have only 1 C-Bus group address, but as many DMX addresses as desired (one to many relation)

What is the replacement for a 5500CN?

The replacement for a 5500CN is 5500CN2.

How to access the Tools Page in DLT to configure time?

Continuously, press and hold down the page button (button 5) for 10 seconds.

What is the code for Cbus PC USB Interface?

The code is 5500PCU

Is the 5500CN and the 550CN2 the same product

The 5500CN2 is the replacement for a 5500CN

What is used as the C-Bus to Bacnet Gateway

The 5500NAC or 5500SHAC can be used as Bacnet gateway depending on the number of Bacnet points which are required.
The 5500NAC has 500 Bacnet Points and the 5500SHAC has 50 Bacnet points.
Bacnet is normally used by Building Management systems.

replacement for the old C-Bus power supply (5100PS)

The replacement for the old 5100PS is a 5500PS, this unit is DIN rail and will require a 4 din rail enclosure to protect it

Where to set Port numbers using NAC or SHAC

Access “Configuration” window on the web browser, select “System”, select “Services” which will allow you access to “HTTP server settings”, this is where your ports can be set.

What is the part number for C-Bus network interface?

5500CN2 is the part number for C-Bus network interface V2. For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=5500CN2

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC (5500SHAC)?

A Configuration Guide exist on the Exchange Community, see the link below or the attachment.

How to control RS-232 enabled devices with C-Bus Network Automation Controller – 5500NAC



 

Do you do a power supply for a 5502DAL DALI gateway?

Yes, the part number for a poewr supply to power the DALI gateway is a 5500PS.
Some of the key features are:
  • 3,750 V RMS AC isolation mains/C-Bus
  • 3 Seconds Warm-up time
  • High efficiency switched mode power supply design
  • DIN Rail mounted
For further information please visit Clipsal - 5500PS - Power Supply, 350mA, 250V

 

Communication issue 174CEV30010 or 174CEV30020 Modbus to Ethernet bridge over an RS232/RS485 network.

I need to take devices off-line for maintenance on my RS232/RS485 network and I am using a CEV30010 or CEV30020 Modbus to Ethernet bridge. I notice that if I take a serial device off-line, it affects other devices that have Ethernet to Modbus communications through the bridge. What can I do?

Decrease your Modbus Message Time Out value. As only 1 outstanding Modbus message is allowed on the serial side of the network, the default timer of 5,000ms (5 seconds), will have to expire before the subsequent message in the queue will be sent.


Show More