Glass Fascia, 6 Gang, Saturn Series, Rectangular

Catalogue Number: 5086F
label - 5086F-30
6 key input glass fascia- pw
5086F-J0 fascia image
label - 5086F-60
label - 5086F-GF
label - 5086F-30
6 key input glass fascia- pw
5086F-J0 fascia image
label - 5086F-60
label - 5086F-GF
Colour: Cream
Colour: Per UOM Std.
  • Cream 1 PCE
  • Black 1 PCE
  • Glass Finish 1 PCE
  • Stainless Steel 1 PCE
  • Pure White 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Australian Series
  • C-Bus
  • Saturn Series
    • Product brand
      Clipsal
      Number of gangs
      6 gangs
      Product destination
      switch
      Material
      glass
      Control type
      button
      Marking
      without marking
      Mounting position
      vertical
      Fixing center
      84 mm
      Length
      116 mm
      Width
      76 mm
      Depth
      12 mm
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Circularity Profile
      ENVEOLI121001EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • End of Life Manual

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      What is the VA rating of a 9001KM transformer light module?

      Issue:
      What is the VA rating of a 9001KM transformer light module?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      9001 KM2 110-120 volt 25-30 hertz      2.2 VA
      9001 KM1 110-120 volt 50-60 hertz      2.4 VA
      9001 KM3 208-220 volt 50-60 hertz      2.5 VA
      9001 KM4 220-240 volt 25-30 hertz      2.2 VA
      9001 KM7 220-240 volt 50-60 hertz      2.0 VA
      9001 KM8 277 volt 50-60 hertz             2.4 VA
      9001 KM5 380-480 volt 50-60 hertz      2.8 VA
      9001 KM6 550-600 volt 50-60 hertz      2.5 VA

      Motor power in kW of a LE1M35U705

      0.25 kW at 415 V AC 50/60 Hz
      0.25 kW at 380...400 V AC 50/60 Hz
      0.12 kW at 240 V AC 50/60 Hz
      0.12 kW at 220...230 V AC 50/60 Hz
       

      What is the part number for the Fascia only on a Cbus Saturn 4 gang plate ?

      The part number will be 5084F- and then colour reference eg 5084F-PW for Pure White Fascia

      Video: How to I replace the modules in my Smart-UPS Modular UPS?

      Issue:
      Replacing modules in Smart-UPS Modular units.

      Product Line:
      Smart-UPS

      Environment:
      All "SUM" models, All Serial Numbers

      Cause:
      Smart-UPS Modular models feature user replaceable Power and Battery modules.

      Resolution:
      The following video details the installation and removal of modules in a Smart-UPS Modular UPS:

      Can the VLT Ref 16060 (analogue voltmeter) be used on DC voltages?

      Goals and Symptoms

      Can the VLT Ref 16060 (analog voltmeter) be used on DC voltages.

      Causes and Fixes

      This VLT ref 16060 is usable for AC voltages only within the range of 50-60 Hz. You cannot use it on DC voltages.


      Legacy KB System (APS) Data: RESL201042 V1.0, Originally authored by KBAdPM on 01/20/2010, Last Edited by KBAdPM on 01/20/2010
      Related ranges: Analog Amp - voltmeters

      Carrier 30RA010-055 AquaSnap® Air-Cooled Chillers with ComfortLink™ Controls 50/60 Hz


      Issue:
      Carrier 30RA010-055 AquaSnap® Air-Cooled Chillers with ComfortLink™ Controls 50/60 Hz

      Product line: 
      Carrier 30RA010-055

      Environment: 
      All Serial Numbers   

      Cause: 
      Controls, Start-Up, Operation, Service, and Troubleshooting

      Resolution:  
      See attached manuals

      Video: Back-UPS Pro M XS; Setting the Display to be always on

      Issue:
      User desires to have the LCD Display illuminated continuously.

      Product Line:
      • APC Back-UPS PRO XS M Series
      • BX850M / BX1000M / BX1350M / BX1500M

      Cause:
      Factory setting disables the display after approximately 30 seconds after user interaction.

      Resolution:
      The following video will provide details related setting the device's LCD display to remain on continuously.

      Video: How do I install a Network Management Card or other Smart Slot Expansion accessory into a Smart-UPS?

      Issue:
      How do I install a SmartSlot Expansion Card in my Smart-UPS?

      Product Line:
      Smart-UPS
      Network Management Card
      Smart Slot Expansion Accessory

      Environment:
      All Serial Numbers

      Cause:
      Expansion cards allow you to add additional functionality to your UPS, such as Network Management or Dry Contacts.

      Resolution:
      The following video explains how to install a Smart Slot Expansion Card in your Smart-UPS unit:

       

      Is the battery only available for the ZART8L eXL Hoist controller?

      Issue:
      Replacement battery for eXL Hoist controller.

      Product line:
      Harmony eXL Hoist controllers

      Environment:
      n/a

      Cause:
      Replacement parts

      Resolution:
      Replacement batteries are not sold separately. 
      For any repair services, contact an Authorized Service Center.

      Currently there is one Authorized Service Center in the USA
      Cincinnati Crane
      10860 Paddy's Run Rd
      Harrison, OH  45030
      Liz McCallum
      ph:  513-202-1408
      em:  lmccallum@cincinnati-crane.com

      The LC1D4011N7 is a discontinued part - what is the alternative?

      LC1D4011N7
      Reason for substitution:  end of life
      Substitution date:  30/12/2009
       
      This product is replaced by:
      LC1D40AN7   -   TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil

      Video: Configure Back-UPS XS & RS LCD units for Full Time Display mode.

      Issue:

      The UPS display keeps turning off after several seconds. What are the steps to keep the display on all the time?


      Product Line:

      APC Back-UPS XS/RS LCD (Red Display)


      Environment:

      Normal Operation


      Cause:

      Display automatically turns off after several seconds.


      Resolution:

      The following video details the process to configure the Back-UPS XS & RS LCD units for Full Time Display mode.

      Video: Battery Replacement for Back-UPS XS & RS LCD units.

      Issue:
      UPS indicates battery requires replacement.

      Product Line:
      • BR1500LCD
      • BX1500LCD
      • BR1300LCD
      • BX1300LCD
      • BN1250LCD

      Environment:
      All Serial Numbers

      Cause:
      Failed selftest resulting in a need for battery replacement. UPS batteries require periodic replacement based on usage and operating environment.

      Resolution:
      The following video will provide details to removing and reconnecting the internal battery for the Back-UPS XS & RS LCD family of units.

      Video: Symmetra RM 6kVA Module Replacement Procedure

      Issue
      I need to install or replace a module in my Symmetra RM 6kVA UPS system.  How do I do this?

      Product Line
      Symmetra RM 6kVA

      Environment
      All Serial Numbers

      Cause
      Symmetra UPS are designed with modularity so that modules can be added or replaced as needed.  This document contains video to aid the user in performing the installation of a new module or replacement of an existing module.

      Resolution
      The following videos detail the process of replacing the Intelligence, Battery, and Power Modules in the Symmetra RM 6kVA UPS.





      Can an ATV680 Active Front End drive run with unbalanced input voltage?

      Issue:
      Can an ATV680 run with unbalanced input voltage?

      Product Line:
      Altivar 680 Process Drives

      Environment:
      All

      Cause:
      Site line voltage is unbalanced 

      Resolution:
      It is NOT recommended to operate an ATV680 AFE on a 480V power system with a voltage unbalance of 4% to 7.5%. This is far outside the specification of the drive.
      The mains voltage must comply with the requirements according to IEC 60038 and EN 50160: 
      - Unbalance between phases: < 2 % 
      - Total harmonic factor THD(v): < 10 % 
      - Maximum single harmonic: < 5 %
      With this supply voltage the drive complies with the specified THDi value.
       
      If the voltage unbalance is 2 … 4% the drive will work but the THDi value will be higher than specified. A voltage unbalance of more than 4% will harm the drive. The input IGBT might overheat and/or the fuses might blow due to unsymmetrical input current. There is also a risk of oscillations if the voltage controller is not able to keep DC bus voltage constant.
       

      What is the part number for a Contactor with Low consumption?

      The part number for a low consumption contactor is LC1D09.
      General Product information:
      Range of product TeSys D
      Product or component type Contactor
      Device short name LC1D
      Contactor application Motor control Resistive load
      Utilisation category AC-1, AC-3
      Poles description 3P
      Power pole contact composition 3 NO
      [Ue] rated operational voltage <= 300 V DC for power circuit
      <= 690 V AC 25...400 Hz for power circuit
      [Ie] rated operational current 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
      25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
      Motor power kW 5.5 kW at 660...690 V AC 50/60 Hz
      5.5 kW at 500 V AC 50/60 Hz
      4 kW at 415...440 V AC 50/60 Hz
      4 kW at 380...400 V AC 50/60 Hz
      2.2 kW at 220...230 V AC 50/60 Hz
      Motor power HP (UL / CSA) 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
      5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
      2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
      2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
      1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
      0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
      Control circuit type AC 50/60 Hz
      Control circuit voltage 415 V AC 50/60 Hz
      Auxiliary contact composition 1 NO + 1 NC
      [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
      Overvoltage category III
      [Ith] conventional free air thermal current 10 A at <= 60 °C for signalling circuit
      25 A at <= 60 °C for power circuit



      For more information please visit https://www.schneider-electric.com.au/en/productcontaLC1D



      Does Schneider Electric offer an external monitor for the Magelis iPC ?

      Yes. There are 4 external LCD monitors available for the Magelis iPC. The monitors attach to the VGA port on the control box.
      Part # information is provided below.
       

      Part #
      Screen Size
      Power Requirement
      MPC YS2 0NAN 00N
      12"
      115-230 VAC 50/60 Hz
      MPC YS2 0NDN 00N
      12"
      24 VDC
      MPC YS5 0NAN 00N
      15"
      115-230 VAC 50/60 Hz
      MPC YS5 0NDN 00N
      15"
      24 VDC

      Legacy KB System (APS) Data: RESL164857 V1.0, Originally authored by on , Last Edited by on
      Related ranges: Magelis Modular iPC

      Are contactors LC1D38.. and LC1D40A.. the same size?

      No the two contactor are not the same size, LC1D40A.. is bigger.

      LC1D38N7
      TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 415 V AC 50/60 Hz coil     LC1D40AN7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil

      For more information see:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D38N7;
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D40AN7




       

      Is 240 volt replacement control coil available for LC1D11500?

      Issue:
      Identifying replacement coil part number

      Product Line:
      IEC contactors and starters

      Environment:
      Products sold and used in the United States

      Cause:
      Replacement control coil needed for older style Tesys Contactor

      Resolution:
      Yes, order LX1D8U5 for 50 hertz, LX1D8U6 for 60 hertz or LX1D8U7 for 50/60 hertz. Average coil consumption is 300 VA inrush 22 VA sealed for 50 hertz, 300 VA inrush 22 VA sealed for 60 hertz and 280 to 350 VA inrush 2 to 18 VA sealed for 50/60 hertz.


      CTA-ID : 11321

      What is the replacement for LC1D115 with LX1D6G7 coil?

      The replacement for LC1D115 with LX1D6G7 coil is LC1D1156F7

      LC1D1156F7
      TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 110 V AC 50/60 Hz coil

      For more information see:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D1156F7

      What is the part number for 24V AC coil for LC1D18 contactor?

      The part number for 24V AC coil for LC1D18 contactor is LXD1B7

      LXD1B7 
      TeSys D - contactor coil - LXD1 - 24 V AC 50/60 Hz for 9… 38 A contactor
      For more information see: https://www.schneider-electric.com.au/en/product-range-selector/664-tesys-d/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_POW_664_L3_Z010%26conf%3Dbasket%26prd_id%3DLXD1B7%26scp_id%3DZ010

      Can the ATS22 and ATS48 soft starters run with 50hz input power supply?

      Issue:
      Can the ATS22 and ATS48 soft starters run with 50hz input power supply?

      Product Line:
      ATS22 and ATS48 series

      Environment:
      All serial numbers for ATS22 and ATS48 series

      Cause:
      N/A

      Resolution:
      Yes, the soft starters can work with both 50/60 hz line power

      What input is designed for a bipolar -10v to +10v input on the ATV32 drives?

      Issue:
      What input is designed for a bipolar -10v to +10v input on the ATV32 drives?

      Product Line:
      Altivar ATV32

      Environment:
      All

      Cause:
      AI2 is default for -10v to +10v input.

      Resolution:
      IO menu AI2 set up

       Bipolar analog input 0 ± 10 V (maximum voltage ± 30 V)

      The + or - polarity of the voltage on AI2 affects the direction of the set point and therefore the direction of operation.

      • Impedance 30 kÙ
      • Resolution: 10 bits
      • Precision ±0.5% in 50/60 Hz for 25 °C, ±0.2% in 50/60 Hz for –10 to +60 °C at Äè = 60°C,
      • Linearity ± 0.2% (max. ± 0.5%), of max. value
      • Sampling time 2 ms

      What is the meaning of the MBP_MSTR error codes 5050, 5055 and 5056?

      Issue
      Explanation of the MBP_MSTR error code Hex values of  5050, 5055 and 5056
       
      Product Line
      140NOE77101, 140NOE77111, 140CPU65xxx
       
      Environment
      Unity Pro, Concept, ProWORX 32
       
      Resolution
       The error code Hex values of 5050, 5055 and 5056 are all similar Ethernet TCP errors. But they do identify where in the TCP connection process the error is occurring.

      The error 5050 Is defined as No Network resource. This is pretty much correctly stated. It indicates that the TCP stack does not have any resources free to open the TCP connection. It has a secondary cause in that the module internally, doesn't have a buffer to use to bring the message across from the backplane to the stack. This is that pool of resources that we refer to when we say the module has a pool of 64 connections that are shared between the client and the server functions.

      The error 5055 is defined as No Remote Resources- This indicates that the NOE tried to open a connection to the remote device (Target) and that device either did not respond or reset the connection. This also has the added issue that as the EF's keep executing for a device that is not present (not answering) The error will gradually propagate across all connections.

      Lastly, The error 5056 defined as Non Operational TCP connection. This is also pretty accurate. The module cannot establish a connection to the device. Often this is seen when a device is not present on the wire when the block starts. It tries to ARP for the address but gets no response or, it simply cannot establish a connection (Port 502 closed). This also can be seen if the Master and Remote Ip addresses are not on the same Network/Subnet address range.

      Can the GV* starters be used on 50 hertz applications?

      Issue:
      GV* Starter for 50/60hz application

      Product Line:
      Motor Starters and Protectors

      Environment:
      PowerPact™ Manual Starters

      Resolution:
      Yes, these starters are rated for 50/60 hertz.

      This applies to all GV2M, GV2ME, GV2P, GV3M, GV3ME devices.

      What is the coil consumption or burden for the Tesys LC*D** contactors?

      Issue:
      What is the coil consumption or burden for the Tesys LC*D** contactors?

      Product Line:
      Tesys Contactors and Overload Relays

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      All AC coils for the LC1D40 through LC1D80 3 or 4-pole contactors have an inrush of 200VA for 50 Hertz applications or 220VA for 60Hz.
      Sealed values are 20VA for 50 Hertz applications or 22VA for 60 Hertz applications. For 50/60 Hertz coil inrush is 245VA and sealed is 26VA


      CTA-ID : 2029994

      What is the part number for 4 pole contactor , reversing for 5.5KW , 40A Single phase motor?

      The part number for 4 pole contactor , reversing for 5.5KW , 40A Single phase motor are LC1DT60A X 2 + LAD4CM
          LAD4CM

      LC1DT60AU7                                                                                                                                                                        D40A to D65A Mechanical Interlock
      TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 240 V AC 50/60 Hz coil

      For further information see:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1DT60AU7
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD4CM

       

      Where do I find the Coil voltage on the Tesys D 3 Pole AC Contactor?

      On the Tesys D 3 Pole AC Contactor you will find the coil voltage marked at the top, behind the Power terminals of the Contactor, for example U7, 240V 50/60 Hz

      For the DC Version, the coil voltage is marked on the front of the Contactor. Hence it has got complete part number for the Contactor on the front, for example: LC1D25BD for 24V DC Coil.

      Can a 60 Hz rated Transformer be energized with 50 Hz source?

      Issue:
      Transformers rated for 60 Hz ONLY are sometimes chosen to be installed in a location that has a 50 Hz Distribution system. 

      Product Line:
      LV Transformers 

      Environment:
      Applies to MOST Transformers made by SquareD/Schneider Electric.  Exceptions are 9070 series Control Transformers and Export Model Transformers which are dual rated for 50Hz and 60Hz.

      Cause:
      Domestic (USA) power systems are rated 60 Hz.   Many other power systems in the world are rated at 50 Hz.

      Resolution:
      A 60 Hz rated transformer can only be used on a 60 Hz system (with certain exceptions -- read further.) Whereas a 50 or 50/60 Hz rated transformer can be used on either a 50 or a 60 Hz rated system.
      Exception: If the energizing voltage does not exceed 83% of the transformers nominal voltage, the transformer can be used. Remember that transformers are simple ratio devices and the output will also be lower. Another important factor to remember is that the transformer`s capacity will also have to be derated at the same ratio of the applied voltage divided by the nominal voltage.

      Example: An EE30T3H, 30kVA 480 delta to 208Y/120 transformer 60 Hz, can be utilized on a 50 Hz system as long as the applied voltage does not exceed 50/60 or 5/6 of the nominal 480, or rather 400 volts. With 400 volts 50 Hz applied, the output voltage will be 400/480 * 208 = 173 volts line-to-line, and 100 volts line-to-neutral, or 173Y/100 50 Hz. As well, the capacity or kVA of the transformer will be 400/480 * 30 = 25kVA. Transformers cannot change frequency, thus frequency in = frequency out. 


        

      ATV58FHD46N4 avec carte Fipio. A chaque remise sous tension le variateur retrouve les reglages usines.

      Goals and Symptoms

      ATV58FHD46N4 avec carte Fipio.
      A chaque remise sous tension le variateur retrouve les réglages usines.

      Facts and Changes

      Mise en service.
      Produit neuf.
      Modification des réglages soit par la pocket soit par PowerSuite.
      A chaque mise hors tension les modifs sont perdues.
      Pas d'utilisation du CMI par la communication.
      Contrôle switch 50/60 Hz : O.K
      Pas de retour réglages usine par menu 7 Fichier.

      Causes and Fixes

      Verifiez que le client n'utilise pas un profil dedié type ATV58FHD46N4 car ce type de profil emet une configation par défaut du PLC vers le variateur à la mise sous tension de l'un ou de l'autre.
      Si le client veut envoyer sa conf lui même, prendre le profil ATV58F PKW.

      What is the maximum control voltage and logic input voltage for the ATS22....S6 and S6U soft starters?

      Issue:
      What is the max control voltage and logic input voltage for the ATS22....S6 and S6U soft starters?

      Product Line:
      Altistart ATS22

      Environment:
      S6
      S6U 

      Cause:
      Control voltage and logic input max voltages allowed.

      Resolution:
      The S6 version was primarily designed for the European market and has  control voltage range (for terminals CL1 and CL2) of 187V AC to 264.5V AC (220 -15% to 230 +15%)).
      The softstart then generates a 24VDC power supply (24VDC +/- 6 V) that is limited to 42 mA.  This supply can be measured between terminals +24 and COM on the control terminal strip and should be present when the 220V power is supplied to the softstart.


      The S6U was designed and qualified for the standard NEMA range, which is: 103.5 ... 126.5V AC and is primarily used in the US.
      The allowed voltage on ATS22•••S6U control terminals (input CL1 and CL2) is from the range: 93.5V ... 126.5V, 50/60 Hz (110 -15% to 115 +10%)



       

      What are the catalog numbers and available voltages for shunt trip and shunt close accessories for the Masterpact NW?

      Product Line:
      Circuit Breakers:

      Environment:
      Applies to Masterpact breakers NW drawout and fixed type.

      Resolution:
      Shunt Trip, Second Shunt Trip, and Shunt Close
      Voltage 50/60 Hz T-, W-, & Y-Frame
      Fixed
      T-Frame
      Drawout
      W- & Y-Frame
      Drawout
      12 dc S47359 S33809 S48490
      24–30 ac/dc S47360 S33810 S48491
      48–60 ac/dc S47361 S33811 S48492
      100–130 ac/dc S47362 S33812 S48493
      200–240 ac/dc S47363 S33813 S48494
      277 ac S47364 S33814 S48495
      380–480 ac S47365 S33815 S48496

      See instruction bulletin, 48049-237-03

      Are line chokes mandatory for ATV61 Drive?

      Issue
      Are line chokes mandatory for ATV61 Drive?

      Product Line:  
      ATV 61

      Environment:  
      All Models , All serial numbers

      Resolution: 
      Line chokes are mandatory:
        
      For ATV 61HU40M3…HU75M3 drives powered by a 200…240 V 50/60 Hz single phase supply voltage. 
      For ATV 61HC11Y…HC80Y drives.
      For ATV 61QC13Y…QC80Y drives.
      Their use is recommended for ATV 61H ... S6X and ATV 61HU30Y…HD90Y drives. 
      Line chokes can be used instead of a DC choke with ATV 61H ... M3 drives powered by a 200…240V 50/60 Hz three-phase supply voltage, and ATV 61H ... M3X and ATV 61 .... N4 drives.

      Note: ATV 61HD90N4…HC63N4 drives, supplied as standard with a DC choke, can be ordered without a choke by adding the letter D at the end of the reference (see page 25 of "Variable speed drives Altivar 61 and Altivar 61 Plus Catalogue October 2011" ). Chokes must be installed upstream of the drive.  Applications The use of line chokes is recommended in particular under the following circumstances:  Close connection of several drives in parallel,  Line supply with significant disturbance from other equipment (interference, over-voltages) Line supply with voltage balance between phases that is more than 1.8% of the nominal voltage, Drive supplied by a line with very low impedance (in the vicinity of power transformers 10 times more powerful than the drive rating),  Installation of a large number of frequency inverters on the same line,  Reduction of overloads on the cos. capacitors, if the installation includes a power factor correction unit.

      Refer to "Variable speed drives Altivar 61 and Altivar 61 Plus Catalogue October 2011" which can be found at www.schneider-electric.com   See Page 74 for Altivar 61:  Reduction of current harmonics using Line Chokes Presentation. Depending on the line supply, one of the main solutions for reducing current harmonics is the Line Choke.  A line choke can be used to provide improved protection against over-voltages on the line supply and to reduce harmonic distortion of the current produced by the drive. The recommended chokes limit the line current.  They have been developed in line with standard IEC 61800-5-1 (VDE 0160 level 1 high-energy over-voltages on the line supply).  The choke values are defined for a voltage drop between phases of between 3% and 5% of the nominal supply voltage. Values higher than this will cause loss of torque. 

      PM8000 Frequently Asked Questions

      Issue
      PM8000 Frequently Asked Questions

      Product Line
      PM8000 series meters
      PM8240
      PM8243
      PM8244

      Environment
      Power Monitoring
      Energy Management
      Specification, Functions and Characteristics, Catalog Number, User Guide, Installation Guide

      Issue
      Find the answer to commonly asked questions about the PM8000 as well as user/installation guides for that meter.

      Resolution

      What are the control power input requirements?
      120 to 300 V DC ± 10%
      50/60 Hz ± 10% : 90 to 415 V ± 10%
      Burden:
          Meter only: 18VA max at 415V AC, 6W at 300V DC
          Fully optioned Meter: 36 VA max at 415V AC, 17W at 300V DC

      What is the rating of the current inputs?
      Nominal 5 A (Class 0.2S) or 1 A (Class 0.5S )
      Measured current: 50 mA to 10 A
      Starting current: 5 mA
      Withstand: 20 A continuous, 50 A @10 sec/hr, 500 @ 1 sec/hr
      Impedance: 0.3 mΩ
      Burden: 0.024 VA at 10 A

      What are the voltage inputs rated at?
      Measured voltage: 57 to 400 V L-N / 100 to 690 V L-L (Wye) or 100 to 600 V L-L (Delta or Wye with unearthed neutral)
      Frequency: 50/60 Hz ± 15%,
      400 Hz ± 10%
      Overload: 600 V L-N or
      1035 V L-L

      What are the options to connect the PM8000 via RS485?
      The PM8000 can be connected via RS485 2 wire. The remote display does not have the option to connect RS485 4 wire as the PM800 does.
      in order to communicate RS485 4-wire, a 2 to 4 wire converter needs to be used.

      What are the maximum number of digital and analog inputs on the PM8000 series?
      27 Digital inputs
      16 Analog inputs

      What is the difference between PM8243 and PM8244?
      PM8243 is DIN rail meter with no display.
      PM8244 is DIN rail meter with remote display. The PM8244 is essentially a PM8243 + remote display (PM89RD96) 

      Documentation:
      For additional specifications for your meter and accessories, view the User Manual on page 155-160 (Document # 7EN02-0336-03).
      PowerLogic PM8000 series User manual: https://www.schneider-electric.us/en/download/document/7EN02-0336/

      For specifications related to installation, such as measured voltage and current ranges, inputs/outputs and control power information, View the installation sheet attached on page 7 (Document # EAV47344-03).
      PowerLogic PM8240 installation guide: https://www.schneider-electric.us/en/download/document/EAV47343/
      PowerLogic PM8243 installation guide: https://www.schneider-electric.us/en/download/document/EAV47344/

      For complete specifications and Catalog number, view PM8000 Technical Datasheet attached.
      PM8000 Technical Datasheet: https://www.schneider-electric.com/en/download/document/PLSED310058EN_Web/

      For information on installing the remote display see the PM89RD96 installation sheet.
      PowerLogic PM89RD96 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47345/

      For information on installing the digital and analog option modules see PM89M2600 & PM89M0024 installation sheet.
      PowerLogic PM89M2600 & PM89M0024 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47347/

      For information on the PM8000 Modbus registers see the PM8000 Modbus Map.
      PM8000 Modbus Map: https://www.schneider-electric.com/en/download/document/PM8000_Modbus_Map/
       

      For the BCPM product, what is the LVCT burden (or the apparent power capacity)?

      Product Line
      BCPM, the LVCT (Low Voltage Current Transformer)

      Environment
      Low Voltage Current Transformer Specification

      Resolution
      The BCPM uses 1/3 V output split-core CTs for the auxiliary inputs
      The 1/3 Volt low-voltage CT specifications are:
      Accuracy: 1% from 10% to 100% of rated current
      Frequency range: 50/60 Hz
      Operating temperature Range: -15° C - 60° C
      Storage temperature Range: -40° C - 70°C
      Humidity range: 0 - 95% non-condensing
      Leads: 18 AWG, 600 Vac, UL 1015 twisted pair, 1.8m standard length
      Max. Voltage L-N: sensed conductor 600 Vac

      The apparent power capacity (or burden rating) doesn't really apply since these are voltage output devices (rather than current mode like traditional Current Transformers). This is one of the great advantages of voltage mode CT (the other being they don't need shorting blocks). The voltage mode CT has an internal burden resistor, usually tens of ohms or less. The input of the meter monitoring the voltage mode CT typically has an input impedance of tens of thousands of ohms or more in parallel with the CTs burden resistor (which can reduce the CTs output voltage very slightly). As long as the series resistance of the wire between the voltage mode CT and the meter is less than hundreds of ohms, the accuracy of the CT will be little affected. Voltage mode CT can drive a much longer wire run using smaller gauge wire than a traditional current mode CT.

       

      What are the coil voltage codes for the LC1D115 / LC2D115 and LC1D150 / LC2D150 TeSys contactor?

      Issue:
      LC1D115 / LC2D115 and LC1D150 / LC2D150

      Product Line:
      Tesys D line Contactors

      Environment:
      North America

      Resolution:
      The following list the more common voltage suffix codes for these product lines.  For a more comprehensive list and to determine compatibility with a given product, refer to the catalog below.

      Note 1: LC1D150 contactors are only available with *7 coil codes.
      Note 2: Coil Code ending number represents frequency rating as follows:
      5 = 50 Hertz
      6 = 60 Hertz
      7 = 50/60 Hertz

      AC Volts ___Code                DC Volts ___Code
      24 ___ B5 or B6 or B7          12 ___ Not Avail.        
      42 ___ D5 or D7                   24 ___ BD
      48 ___ E5 or E6 or E7          36 ___ CD
      110 ___ F5 or F6 or F7         48 ___ ED
      115 ___ FE5 or FE7             60 ___ ND
      120 ___ G6 or G7                72 ___ SD
      127 ___ FC5 or FC7            110 ___ FD
      208 ___ L6 or LE7               125 ___ GD
      220 ___ M5 or M6 or M7       220 ___ MD
      230 ___ P5 or P7                 250 ___ UD
      240 ___ U5 or U6 or U7        440 ___ RD
      277 ___ W6 or UE7                
      380 ___ Q5 or Q6 or Q7                
      400 ___ V5 or V7                
      415 ___ N5 or N7                
      440 ___ R5 or R6 or R7                
      480 ___ T6 or T7                
      500 ___ S5 or S7                


       

      What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

      Issue:  
      What is the operating voltage tolerance, catalog numbers, and clearing times for the Masterpact NT and NW shunt trip and shunt close coils?

      Product Line:
      Masterpact NT NW

      Resolution:
      Shunt trip:  operating threshold is 0.7 to 1.1 Vn (nominal voltage)
      Shunt close:  operating threshold is 0.85 to 1.1 Vn
      Catalog numbers are the same for MX and MN (shunt trip and shunt close) devices; function is determined by placement in the breaker.
       
      Voltage 50/60 Hz  T-, W-, & Y-Frame Fixed  T-Frame Drawout  W- & Y-Frame Drawout 
      12 dc  S47359  S33809  S48490 
      24–30 ac/dc  S47360  S33810  S48491 
      48–60 ac/dc  S47361  S33811  S48492 
      100–130 ac/dc  S47362  S33812  S48493 
      200–240 ac/dc  S47363  S33813  S48494 
      277 ac  S47364  S33814  S48495 
      380–480 ac  S47365  S33815  S48496 

      MX operating time at Vn:  50 ms ±10 (NW and NT)
      XF operating time at Vn:  
      70 ms ±10 (NW ≤ 4000 A)
      80 ms ±10 (NW > 4000 A)
      55 ms (NT)

      NOTE:  Shunt trip (MX) and shunt close (XF) circuits must be energized for minimum of 200 ms. In other words, don't use an impulse signal. Use a signal of at least 200ms.

      What are the UL and IEC ratings for the Merlin Gerin C60 breakers?

      Issue:  
      What standards do Multi 9 C60 breakers conform to? 

      Product Line:
      Multi 9 C60 Breakers 

      Environment:  
      Multi 9 UL and IEC C60 type breakers

      Resolution:
      Ratings per UL Standards     UL 489/CSA C22.2 No.5 C60   UL 489/CSA C22.2 No.5 C60  
            (240 Vac)       (480Y/277 Vac)    
      Number of Poles     1P 1P 2P 3P 1P 2P 3P  
      Rated Current at 77°F (25°C)     0.5–20 A 25–35 A 0.5–35 A 0.5–35 A 0.5–20 A 1–20 A 1–20 A  
          120 V 10 kA 10 kA 10 kA  
        AC 50/60 Hz 240 V 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA  
      Interrupting Ratings   277 V 10 kA 10 kA 10 kA  
      as per UL 489/CSA C22.2 No.5   480Y/277 V 10 kA 10 kA  
        DC 60 V 10 kA 10 kA 10 kA  
          125 V 10 kA  
                           
      Ultimate Breaking Capacity (Icu) AC 50/60 Hz 240 V 10 kA 10 kA 20 kA 20 kA 10 kA 10 kA 10 kA  
      as per IEC 60947-2 Standard   415V 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA 10 kA  
          440V 6 kA 6 kA 6 kA 6 kA  
      Ratings per UL Standards      UL 1077 C60            
      Number of Poles     1P 2P 3P 4P        
      Rated Current at 77°F (25°C)      0.5–63 A  0.5–63 A  0.5–63 A  0.5–63 A        
          120 Vac 10 kA        
        50/60 Hz 240 Vac 10 kA 10 kA 10 kA 10 kA        
      Interrupting Ratings   277 Vac          
      as per UL 1077   480Y/277 Vac              
          65 Vdc 10 kA        
          125 Vdc 10 kA        
          240 V 10 kA 20 kA 20 kA 20 kA        
      Ultimate Breaking Capacity (Icu) AC 50/60 Hz 415V   10 kA 10 kA 10 kA        
      as per IEC 60947-2 Standard   440V 6 kA 6 kA 6 kA        
                           
      Ratings per IEC 60947-2    N40  C60N  C60H  C60L  C120H
      Number of Poles   1 (Ø + N) 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4
      Rated Current 25°C (77°F) In 1–40 A  1–63 A 1–63 A 1–40 A  1–40 A 1–25 A 1–25 A
      Rated Current (A) 40°C (104°F) In  —  —  —  —  —  —  — 63–125  63–125
      Rated Voltage Ue 230 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V
        130 Vac  —  —  —    —  —  —    —
        230–240 Vac 7.5 kA 10 kA 20 kA 15 kA 30 kA 25 kA 50 kA 15 kA 30 kA
        400–415 Vac 2 kA 3 kA 10 kA 4 kA 15 kA 6 kA 25 kA 4 kA 15 kA
      Ultimate Breaking Capacity (Icu) 440 Vac  —  — 6 kA  — 10 kA  — 20 kA  — 10 kA
      as per IEC 60947-2 Standard 1P 60 Vdc  — 15 kA  — 20 kA  — 25 kA  —  —  —
        2P 125 Vdc  —  — 2P 20 kA  — 2P 25 kA  — 2P 30 kA  —  —
           —  — 3P 30 kA  — 3P 40 kA  — 3P 50 kA  —  —
        3P 250 Vdc  —  — 4P 40 kA  — 4P 50 kA  — 4P 60 kA  —  —

      What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

      Issue:
      Identifying replacement coils for tesys D non-reversing and reversing conactors

      Product Line:
      IEC Contactors and Starters

      Environment:
      Products sold and used in the United States

      Cause:
      Replacement coil is needed

      Resolution:
      DC replacement coils are not available.
      AC Coils are 50/60 hertz for voltages as listed below:

      Volts - Part Number
      12 ____ LXD1J7
      21 ____ LXD1Z7
      24 ____ LXD1B7
      32 ____ LXD1C7
      36 ____ LXD1CC7
      42 ____ LXD1D7
      48 ____ LXD1E7
      60 ____ LXD1EE7
      100 ___ LXD1K7 ( never brought to North America )
      110 ___ LXD1F7
      115 ___ LXD1FE7
      120 ___ LXD1G7
      127 ___ LXD1FC7
      200 ___ LXD1L7
      208 ___ LXD1LE7
      220 ___ LXD1M7
      230 ___ LXD1P7
      240 ___ LXD1U7
      277 ___ LXD1W7
      380 ___ LXD1Q7
      400 ___ LXD1V7
      415 ___ LXD1N7
      440 ___ LXD1R7
      480 ___ LXD1T7
      575 ___ LXD1SC7
      600 ___ LXD1X7
      690 ___ LXD1Y7


      Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

      There is an application with Altivar 38 with pump switching card where the auxiliary pump is driven by an Altistart 48.There is also Modbus connection...

      Goals and Symptoms

      There is an application with Altivar 38 with pump switching card where the auxiliary pump is driven by an Altistart 48.There is also Modbus connection where the master is a Twido PLC and the slaves are the ATV38 and the ATS 48. The problem is that en error ERR 7 (erreur LS) is appeared at the ATV38 display.What kind of error is that and what can we do about it?

      Facts and Changes

      ATV38 with Modbus connection

      Causes and Fixes

      Product trips transiently to "Err3" or "Err7" fault. Both faults type are generated by the display module.
      This one communicates with the microprocessor of control card .
      When incorrect messages occur during the communication and after some repetition of exchanges , the display module shows to "ErrX".
      This is a very difficult fault to reproduce because depending of environment ( lenght of wire between display module and control board , motor running, disrupted site ) and the combination between display module and control board.

      Origin of problem :

      Insufficient immunity of communication facing the various disturbances.
      The communication frames managing is made by integrated components called "drivers". One is located on control board, the same is inside display module. This fault is the result of wrong interpretation of display module of logic level between two communication frames.
      This technical conceived problem is appeared from August 2000.

      Corrective action:

      This failure has been resolved by a modification of two values of resistors inside the display module.
      The revision levels become:
      · A20, B20 for the ATV58 display modules.
      · A02 for the ATV58Fdisplay modules.

      This evolution is applied from the week 47/2000 on all manufactured PRODUCTS and all VW3A58101 spare parts.


      Information for internal use:

      We have noticed that anyway neither control board nor display module have never been directly to the fault origin . Fault "Err X" is always due to the association of two items.

      On no account this failure cannot to disrupted the motor running but she can to disturb only the programming of product.

      If during the programming, a customer encounters to " Err3 " or " Err7 " with a product manufactured from the week 31/00 to 46/00 , it is advised to exchange only the VW3A58101 display module.

      This problem can also appear if the baudrate of internal communication was modified ( subD 9 pins ) and there is a difference between the keypad and internal modbus.

      A solution is to reset the inverter with the 50/60 Hz switch to return the baudrate in factory setting, don't forget to accord the Twido PLC.


      Legacy KB System (APS) Data: RESL156317 V3.0, Originally authored by on , Last Edited by on
      Related ranges: Altivar 38

      What is the replacement for the 4TCD1 din rail mount timmer?

      The direct replacement for the 4TCD1 din rail mount timmer is CCT15854.
      Some of it's key features are:
      Features Descrition
      Device short name IHP 1c 18 mm
      Product or component
      type
      Programmable digital time switch
      Number of channels 1
      Battery type Lithium
      Function available Operating hours counter
      Automatic winter/summer time changeover
      Type of setting Absence for holidays function
      PIN code
      Available equipment Memory key
      Programming kit
      Language English
      French
      German
      Italian
      Portuguese
      Spanish
      Device application Building
      Cycle duration 24 hours + 7 days
      Maximum number of switchings 56
      Minimum interval duration 1 min
      Accuracy +/- 0.5 s/day 25 °C
      Power consumption 0.4 W
      Maximum switching current 4 A - 250 V AC pf = 0.6
      16 A - 250 V AC pf = 1
      [Ue] rated operational voltage 230 V ( - 15...10 % ) AC 50/60 Hz
      Display type LCD
      Battery life 10 yr
      Backup time 10 years time and program saving
      Mounting support DIN rail
      9 mm pitches 2
      Colour tint White (RAL 9003)
      Connections - terminals Screwless terminals : 2 x 0.5...2.5 mm²
      Width 18 mm
      Height 90 mm
      Depth 66 mm
      Product weight 0.09 kg
      Ambient air temperature for operation -25...55 °C
      IP degree of protection IP20 B

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=CCT15854
      Or see PDF attached


       

      Will the Compact NSX breaker be for sale in the USA or Canada?

      Issue:
      Where can I buy a Compact NSX breaker?

      Product Line:
      Circuit Breakers

      Cause:
      This breaker is popular overseas and there is interest in the US

      Resolution:
      There are no plans for a general release of the Compact NSX breaker line in North America, since the NSX is not UL Listed to UL489. (UL 489 is the standard commonly required in the US.) In the US, the Powerpact Circuit Breakers should be used (Powerpact breakers are UL, CSA and IEC-rated).

      If an existing piece of equipment has an NSX breaker which needs replacing, we have made a few catalog numbers available for sale in the US. The list of numbers will vary based upon need. Contact your local authorized Schneider Electric distributor for assistance on your specific NSX catalog number.

      For support on these breakers, Please see the following link to Global Operations where you can select other Countries:
      https://www2.schneider-electric.com/sites/corporate/en/support/operations/local-operations/local-operations.page

      What ION7550/ION7650 firmware downloads are available and what changed?

      Issue
      Where can I download ION7550/ION7650 firmware and what was updated?

      Product Line
      ION7550/ION7650

      Environment
      Firmware Download Links

      Resolution
      The table below lists the current and past firmware versions with associated download and What's New? document links:
      Firmware Version ION7650 Firmware* ION7550 Firmware* What's New? Document Notes Release Date
      V411 Download Download See Below Only compatible with -05 hardware July 2018
      V410 Download Download Details Only compatible with -05 hardware March 2017
      V401 Download Not Available Details Only compatible with -05 hardware March 2016
      V400 Download Not Available Details Only compatible with -05 hardware Feb 2015
      V375 Download Download See Below Use for -04 and older hardware July 2018
      V374 Download Not Available Details   March 2016
      V373 Download Download Details   Dec 2014
      V371 Download Download See Below   June 2012
      V366 Download Download See Below   Feb 2012
      V360 Not Available Download Details    
      V355 Not Available Not Available Details    
      V350 Not Available Not Available Details    
      V331 Not Available Not Available See Below    
      V330 Not Available Not Available Details    
      V321 Not Available Not Available Details    

      *Older versions with 'Not Available' status may be requested from Technical Support if required.

      Additional descriptions for firmware versions are as follows:


      V411/375
      No new features.
       
      V410​
      This firmware release supports EN50160:2010 (Edition 4) and IEC 61000 4-30 Edition 3. EN50160 is a European standard that defines the voltage characteristics of the electricity supplied by public distribution systems. The latest firmware version for this meter now supports the EN50160:2010 (Edition 4) standard. The IEC 61000-4-30 (4-30) standard defines methods for measurement and interpretation of power quality parameters in 50/60 Hz AC power supply systems. The standard describes measurement methods for relevant parameters to obtain reliable, repeatable and comparable results using any compliant meter. 
       
      V400 
      V400 is a general firmware release that adds support for new metering hardware. In addition this firmware release reduces the 7x50e and 7x50s variants into one allowing for IEC61850 and10Meg of logging memory to occur upon the same device. V400 adds compatibility for the -05 hardware revision option. This can be found as the last two digits of a meters serial number. V400 will NOT be compatible with previous versions of hardware ( -04 or earlier). In addition previous firmware revisions (pre V400) will not be compatible with the -05 hardware. We have consolidated the e (IEC61850) and s (standard) variants into one release. This means ALL devices ordered with V400 will now contain IEC61850 functionality as well as contain the 10M logging memory. Both features can be implemented in frameworks simultaneously. NOTE: To support the new features in v400, download the latest version of ION Setup from the website. 
       
      V401/374
      *The V374s version is the standard version. *The V374e version is for IEC61850 protocol support. This firmware is for the older hardware platform (RevA, if you like). The equivalent firmware for the RevB hardware platform is V401.
       
      V373​
      Firmware V373 is a general firmware release that adds support for the following features: (1) Access to more voltage data (2) Enhanced interharmonic distortion calculation (3) Display module enhancements (4) initial release of the PowerLogic Remote Display and also includes security enhancements. NOTE: For more detailed information about any of these features, please find the document entitled "What’s new in ION7550/ION7650 v373" (7EN12-0276-00). In preparation for upgrading your meter's firmware please download the latest firmware version (.upg file) and the appropriate Meter Template (.dcf file). Note that releases of Meter Template files often do not keep pace with firmware releases so do not be concerned if the firmware version number in the label of latest available template file is not as high as the version number of the firmware file. The main thing is to get the latest available file for each of firmware and template. ION Setup (freeware utility) is the recommended tool for the firmware upgrade process. See the Upgrading ION Device Firmware technical note for complete details.
      Important Notes: *Generally, two versions of firmware are available for the ION7x50 devices: VXXXe with IEC 61850 implementation, and; VXXXs without IEC 61850 implementation. *IEC61850 is supported with the consequence of a reduction of the available logging memory. If you upgrade a 10MB meter to use IEC 61850 firmware, the meter’s logging memory will be reduced to 5MB. If the meter is subsequently loaded with non-IEC 61850 firmware, the meter’s original logging memory will be restored.  

       
      V371​
      Firmware V371 is a general firmware release that adds support for the initial release of the PowerLogic Remote Display and also includes security enhancements. In preparation for upgrading your meter's firmware please download the latest firmware version (.upg file) and the appropriate Meter Template (.dcf file). ION Setup (freeware utility) is the recommended tool for the firmware upgrade process. See the Upgrading ION Device Firmware technical note for complete details.
      Important Notes: *Two versions of firmware are available below namely: V371e with IEC 61850 implementation, and;V371s without IEC 61850 implementation. *IEC61850 is supported with the consequence of a reduction of the available logging memory. If you upgrade a 10MB meter to use IEC 61850 firmware (7650V360e), the meter’s logging memory will be reduced to 5MB. If the meter is subsequently loaded with non-IEC 61850 firmware (7650V360s), the meter’s original logging memory will be restored. 
       
      V366
      Firmware version 366 (V366) for the ION7x50 adds Modbus mastering over TCP support for up to 10 connections. This is in addition to the 8 available Ethernet connections and is also in addition to the Modbus master functionality in both serial ports. This release also includes various communications bug fixes. When upgrading your meter's firmware please download the latest firmware version (.upg file) and the equivalent Meter Template (.dcf file). You can upgrade meter firmware using ION Setup or ION Enterprise. See the Upgrading ION Device Firmware technical note for complete details
      Important Notes from V360 (applicable to V366): * Two versions of V360 firmware are available below: with IEC 61850 implementation (7x50V360e) and without IEC 61850 implementation (7x50V360s). * IEC 61850 can only be purchased on 5MB meters, not 10MB meters. If you upgrade a 10MB meter to use IEC 61850 firmware (7x50V360e), the meter’s logging memory will be reduced to 5MB. If the meter is subsequently loaded with non-IEC 61850 firmware (7x50V360s), the meter’s original logging memory will be restored.* The non IEC 61850 firmware version (7x50V360s) still has new features available, such as COMTRADE waveform recording.* To find ICD files related to the IEC61850 implementation on ION7x50 meters, search the keyword icd on any schneider-electric.xxx site 
       
      V360
      Firmware version 360 (v360) for the ION7550/ION7650 adds IEC 61850 server functionality. This includes FTP support and the ability to save waveform data in COMTRADE format.
       
      V355
      Firmware version 355 (v355) and factory template 7550/7650_v355_FACPQ_V3.4.0.0.0 for the ION7550 / ION7650 adds International Electrotechnical Commission (IEC) 61000-4-30 Class A Edition 2 standard compliance for the ION7550 / ION7650 and the ability to configure the event priority value for digital input state change events.
       
      V350
      Firmware version 350 (v350) for the ION7550 / ION7650 adds a number of new features as well as support for the new Communications Card.
      New features
      • Disturbance Direction Detection capabilities are now available.
      • Localization options have been added to the meter, including:
        • the ability to set the language of the front panel display to English, Spanish, French or Russian.
        • the option to customized IEEE/IEC convention settings.
      • Setpoint learning functionality has been added. 
      • The meter can function as a Modbus gateway, forwarding Modbus packets from a master through the meter to downstream serial devices.
      • Trending and Forecasting functionality has been added.
      • The meter can now communicate selected values over the Ethernet via SNMP.
      • Support for a new communications card has been added.
      • A default IP Address has been added. For more information on these features, see the relevant sections in this document.
      Other changes
      • Power Availability has been removed from the default template.
      • V4, I4, I5 waveform recorders have been removed from the default template.
      • Thermal Demand has been removed from the default template.
       
      V331​
      Firmware version 331 (v331) for the ION7550/ION7650 meter improves Class A compliance with the IEC 61000-4-30 (2003 - 1st Edition), or “4-30” power quality standard. Compliance improvements included are Class A Flicker with no exceptions
       
      V330
      Firmware version 330 (v330) for the ION7550 / ION7650 meter supports Class A compliance with the IEC 61000‐4‐30 (2003 ‐ 1st Edition), or “4‐30” power quality standard.
       
      V321
      Firmware version 321 features enhanced Modbus Mastering with four ION modules new to the ION 7550 /ION 7650 platform. The Modbus Master Device and Modbus Master Mapping modules work together to offer improved setup of Modbus read functionality. The Averaging module provides simple averaging and easily links with other Modbus modules. The Modbus Master Options module allows multiple serial connections to different loops of Modbus devices.
      Advanced meter security provides an additional layer of security, allowing you to configure up to 16 users, each with unique access rights to the meter. Access rights consist of different security levels, permitting different users to read values, perform resets, time sync the meter clock, or configure meter settings.