Specifications

hide show
Range of product
Series 4
Product brand
Clipsal
Product or component type
wide filler strip
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
16 g
Package 1 Height
13 mm
Package 1 width
52 mm
Package 1 Length
108 mm
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure
ENVPEP121018EN

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Product Environmental

  • Specifications

  • Corporate Marketing

Frequently Asked Questions

hide show

Clipsal 426 is discontinued, what is a suitable replacement

the 426 is desigend to fit a junction box - an alternative would be to use the PDL570R (surface socket) + PDL530 (mounting block)

Where to download the Zelio Soft2 version 4.6 from??

What is the amount of SF6 gas in 24 kV SF Circuit Breaker range.

In 24 KV SF Circuit Breaker range, the weight of the SF6 gas per pole for different Circuit Breakers is as follows:
 
  1. SF1 Type 1 – 49 grams 
     
  2. SF1 Type 2 – 112 grams
     
  3. SF2 – 240 grams

How do I upgrade Vijeo Designer 4.6 to Vijeo Designer 6.2?

You will have to upgrade from Vijeo Designer 4.6 to Vijeo Designer 6.1 Then you can upgrade from 6.1 to 6.2.

How many pounds of SF6 gas does the N, RL, U and W series reclosers contain?

Issue 
Need to know how much SF6 gas is used in the Reclosers for Schneider.

Product Line
Nulec Reclosers
N-Series 
RL-Series
U-Series
W-Series

Resolution
The amount of SF6 gas per recloser is as follows:
N-Series = 1.8Kg = 3.97lbs
RL-Series = 0.8Kg = 1.76lbs
U-Series = 0Kg
W-Series = 0Kg

What is the part number for a Pole Filler for the 4FCS /4CS Series Switchboards?

Unfortunately this part is not a standard product however, it can be ordered as a special through our quotes team. The part number is 4CSF8-1.

Do you sell the 486 RCD tester leads as a spare part?

No, unfortunately this tester is no longer available. Therefore spare parts have also been discontinued.

This tester has been replaced with the all in one 493 Spark-E-Mate.

Some of the key features are:

  • Earth continuity
  • Insulation resistance
  • Polarity
  • Circuit connections 
  • fault loop impedance
  • RCD Trip
  • digital LCD dispay
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=493

Is it possible to get replacement blades for a 6220-0?

Yes it is.
The part number is SP-254-16709.
This is done as a special and will take between 4-6 weeks for delivery.

For more information, visit the website at www.clipsal.com/Trade/search-results and click on the link to view a brochure.

What is meant by an Air Circuit Breaker?

Issue:
What are Air Breakers?

Product Line:
Breakers

Environment:
Distribution Equipment

Resolution:
"Air breaker" is a general industry term referring to circuit breakers which use an air medium for interruption and contact isolation as opposed to a vacuum or a gas such as SF6.


 

What is the replacement part for Premium PLC TSXP573623M?

Goals and Symptoms

What is the replacement part for Premium PLC TSXP573623M?

Facts and Changes

This resolution informs the user of the replacement part for a Premium PLC bearing part number TSXP573623M and highlights the differences.

Causes and Fixes

The replacement part number for Premium PLC bearing part number TSXP573623M is a TSXP573623AM.
The following explains the salient features of the "A" PLCs.

  • · Originally Premium CPUs(1) were equipped with 486 DX5 INTEL microprocessor. As this component became obsolete in 2006, Schneider Automation replaced it with the 486 DX4.
    • (1) only part number TSXP57303M, TSXP57353M, TSXP573623M, TSXP57453M and TSXP574823M are concerned.
  • · The CPUs equipped with 486 DX4 microprocessor are differentiated from those equipped with 486 DX5 by a A letter in the part number as illustrated as follows:
Old CPU equipped with 486 DX5 microprocessor New CPU equipped with 486 DX4 microprocessor
TSXP57303M
TSXP57303 A M
TSXP57353M
TSXP57353 A M
TSXP573623M
TSXP573623 A M
TSXP57453M
TSXP57453 A M
TSXP574823M
TSXP574823 A M
  • · The new CPUs (part number TSXP57*AM) have same capabilities as old CPUs (part number TSXP57*M), excepted the scan time which is slightly longer.
    • The spreadsheet hereunder provides scan time increasing for new CPUs regarding the corresponding old one.

  • · Consequences on the Operating System : the OS of old CPUs is not compatible with new ones. Then OS for new CPUs (TSXP57xx3AM) are provided separately.

Legacy KB System (APS) Data: RESL210966 V1.0, Originally authored by TVe on 03/15/2013, Last Edited by TVe on 03/15/2013
Related ranges: Modicon Premium

What is the explanation of the Parameter FLC1 in TeSys T.

FLC1 is the parameter to enter the Motor nominal current in TeSys T. In this parameter, the Motor nominal current is entered as a percentage of the rated value of the TeSys T. 

Example:
 
For TeSys T of range 8Amps (LTMR08) and a motor of 2 Amps nominal current, you have to set the FLC1 value to 25% because the Motor nominal current is 25% of the full load current of TeSys T Module (LTMR08).
 
This means that the current in register 466 (value of current in percent) take the value of 100% when you reach 25% of the current of the TeSys T Module rated current value.

Does Multi-9 have a 480V Delta rating?

Issue:
Multi 9 (M9) breaker and 480V breakers

Product Line:
Circuit Breakers

Environment:
Applies to Multi 9 (M9) circuit breakers

Cause:
Need a 480V breaker in the miniature style.

Resolution:
No, the Multi 9 breakers are not rated 480V delta.

The UL 1077 listed M9 is rated for 480Y/277, not 480V delta.
The IEC version has a 440Vac rating
The UL 489 version has a 480Y/277vac rating (.5A-20A), 240 volts (.5 -35A).

For additional information on the ratings please see systems catalog in download center.
LVCATM9OEM_EN