unswitched skt outlet 10a
unswitched skt outlet 10a
unswitched skt outlet 10a
unswitched skt outlet 10a

Auto-Switched Caravan Socket Outlet IP34 10A

Catalogue Number: 415VF
unswitched skt outlet 10a
unswitched skt outlet 10a
unswitched skt outlet 10a
unswitched skt outlet 10a
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Quantity per set
set of 1
Cover type
full cover plate
Socket additional information
with hinged lid
Marking
without marking
Local signalling
without light indicator
Device mounting
flush
Fixing mode
by screws
[In] rated current
10 A
[Ue] rated operational voltage
250 V AC
Depth
38 mm
Length
101 mm
Width
80 mm
Fixing center
76 x 65 mm
Standards
  • AS/NZS 3112
  • AS 3100
  • AS 3109
  • AS/NZS 3122:approval number S/1
    • IP degree of protection
      IP34
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Free of Substances of Very High Concern above the threshold
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Compliant
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Product Environmental

      • Installation Instruction

      • Specifications

      • Case Studies

      • Certificates (MSDS)

      Frequently Asked Questions

      hide show

      What is the part number for a 20A, 415V, contactor with a 240V coil?

      The part number for a 20A, 415V, contactor with a 240V coil is a LC1DT20U7.

      What are the part numbers of the 32A and 45A cooker switches that are unmarked?

      Below are the part numbers of the cooker switches that are unmarked.
      2031/45 Single-pole 250V, 45A - 2000 Series
      C2031/45 Single-pole 250V, 45A - C2000 Series
      2031D32 Double-pole 415V, 32A - 2000 Series
      C2031D32 Double-pole 415V, 32A - C2000 Series
      2031/45N Single-pole, includes Neon, 250V, 45A - 2000 Series
      C2031/45N Single-pole, includes Neon, 250V, 45A - C2000 Series
      2031D32N Double-pole, includes Neon, 415V, 32A - 2000 Series
      C2031D32N Double-pole, includes Neon, 415V, 32A - C2000 Series
      For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000272.pdf

      What is the code for a 415VAC coil for a LC1D40A Contactor?

      The 415V coil is LXD3N7

      What is part number for 3p 80amp 415v c/b?

      The part number for 3p 80amp 415v c/b is part number A9N18468.

      What is the part number for a 100A 3 phase ,415V coil voltage?

      The part number for a 100A 3 phase , 415V coil voltage is a LC1D80N7.

      What is the maximum voltage for the DBS boards

      Maximum voltage is 415V

      What is the part number for the 415V AC shunt trip for the NSX100 to NSX630 Breakers?

      The part number for the 415V AC shunt trip for the NSX100 to NSX630 Breakers is LV429388.

      https://www.schneider-electric.com.au/en/search/LV429388

      What is the part number for the 415V AC Coil for the LC1D1156 Contactor?

      The part number for the 415V AC Coil for the LC1D1156 Contactor is "LX1D8N7"

      https://www.schneider-electric.com.au/en/search/lx1d8n7


       

      What is the replacement for a LC1D173 with a 415V coil?

      The replacement for LC1D173 with a 415V coil is a - LC1D32N7.

       

      What is the part number of the replacement RCD to suit 56SC420RC, 500V, 20A RCD protected switched outlet?

      4RC425/30 is the part number of the RCD supplied with 56SC420RC. 4RC425/30 is 4 pole rated to 415V, 25A, 30mA.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4RC425/30
       

      What is the part number for 4 pole, 415V Coil contactor and 3A overload?

      The part number for 4 pole, 415V Coil contactor and 3A overload is LC1DT20N7 and LRD08



      For more information on either item refer to:
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1DT20N7
      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LRD08

      I am looking for a 240v double pole 20amp switch

      Have to use a 415v unit in the 56 series range - PDL 56SW220

      What is the voltage rating for the PDL 501

       The PDL 501 has a voltage rating of 415V AC

      What is the replacement code for a 18371?

      A9N18371
      C120N 4P 63A C 10000A 415V MINIATURE CIR

      What is the code for a 415V coil only for LC1D18 contactor?

      LXD1N7 is the code.

      what coil voltage is the LC1D25N7 TeSys D?

      it is 415v a.c.

       

      Can I purchase a PDL 615MF without the bit in middle

       Not available

      What is the replacement contactor for a 6C12/10 415V 5.5kW?

      The 6C12/10 contactor has been discontinued for some time. The closest alternative would be the LC1D12**

      ** = coil voltage- 24V=B7, 32V=C7, 48V=E7, 110V=F7, 220V=M7, 240V=U7, 415V=N7

      For further information please visit https://www.schneider-electric.com.au.

      What is the 415v remote reset for the LRD14 overload?

      The part number for the415VAC or DC remote reset for the LRD01...35 and the LRD313....365 is LAD703N
      See data sheet for more information......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD703N...User-added image
       

      Is there a 3 position marked "1, 0, 2" 2 pole cam switch 16A available?

      Yes, the part number for a 3 position marked "1, 0, 2" 2 pole cam switch 16A is a 7GN12/52/U.
      Brief :

       Rotary Cam Switches and Accessories, Rated Thermal Current (Ith) = 12A AC23A rating - 6kW at 415V. Rated Insulation Voltage Ui = 480V. Maximum 16A Fuse (gG/gL) for 3kA short circuit protection, 2 Pole 12A 60° changeover switch with Off marked 1-O-2.

      Some of the key features are:

      • Front mounting
      • AC23A Rating
      • Changeover switch with OFF marked 1-O-2
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=7GN12/52/U​

       

       

       

      What is the part number for a replacement 415v coil for LC1F150 and LC1F115?

      AC coil for both
      LX1FF415



       

      What is the replacement overload to suit the 56ROL9/01?

      The replacement overload for the 56ROL9/10 is a LRD14.

      Relay Setting Range (A) DOL 415V (kW) Star Delta 415V (kW)  For use with the contactor LC1 Part Number
      7-10 Amp 4kW - D09...D38 LRD14

       

      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=LRD14

      What is the inrush of a K range contactor

       The inrush is 30VA but the holding is 4.5VA

      Is there a horizontal version of Z4061D32, 32A, 415V double pole Saturn Zen cooker switch?

      In Z4061D32, the Cooker Marking on the Cooker switch mechanism can be removed and turned 90 degrees to allow for both vertical or horizontal mounting.
      For further information, please refer to the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=Z4061D32
      User-added image



       

      Can WMS320, 3 pole, 20A, 415V WilcoROWCO metal clad switch be locked in the ON and OFF position?

      All WilcoROWCO switches incorporate a positive rotary switch action and a provision in the switch knob for an 8mm padlock is also provided for locking OFF. If locking is required in ON position, simply drill a hole where necessary. ON and OFF positions are clearly marked with raised lettering so they will never wear off.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=WMS320
       

      Can the contactor be swapped or changed in a LE1M35 DOL starter?

      No the contactor is fixed in the body. The only item that can be swapped is the overload.
      The Overload belongs to the K Range
       

      What size enclosure / mounting base does the 56SW350 fit on?

      The base to go with this switch, is a 56E1. This enclosure is suitable for 415V switches 56SW220...350.

      https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=pdl56e1gy

      what are the dimensions for a T100, T100F, T150, T150LF, T150F

       140 x 94 x 81mm ( L x W x D)

      What is the dimensions of a T150, T150LF, T150F

       140 x 94 x 81mm (L x W x D)

      Is there a replacement for the Domestic Safety Switch C Curve 40A 4 pole 12225?

      No, there is no direct replacement. However, in a diffrent range there is a Resimax, 415V, 40A, 30mA, 4 pole, Domestic safety switch. It is four modules wide and the part number is RCD440/30.

      Key Features
      • Unique new white finish for a fresh modern look
      • Base module = 18 mm wide, compact standardised and consistent module dimensions
      • Lift-up terminals. Safer ‘no hot spot’ terminations and all cable strands are locked in
      • Cable automatically guided to the correct position: terminals with guard
      • Fast closure
      • The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety
      • Operating temperature: -5 to 40 deg C
      • 6 kV Rated impulse withstand voltage



      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=RCD440/30

      What is the recessed version of the 415VF15?

      The 415VF15 is a recessed product.

      spare 415VAC coil for LC1D80 Contactor ?

      Code = LX1D6N7

      What reference do I add to the CAD32 or CAD50 to sepcify the coil voltage?

      Add one of the codes listed in bold below to the end of the code. For example a 24V AC CAD32 would be CAD32B7

      AC | 24V = B7 | 110V = F7 | 240V = U7 | 415V = N7
      DC | 24V = BD

      What replaces LC1K0910Q7 Contactor?

      LC1K0910N7 replaces LC1K0910Q7 Contactor.
      The coil is rated @ 415V AC  but can operate at plus or minus 10% of coil votlage.ie  Between 373.5V AC AND 456.5V AC

      LC1K0910N7
      TeSys K contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 400...415 V AC coil

      For more information see;
      https://www.schneider-electric.com/en/product-range-selector/666-tesys-k/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_POW_666_L3%26prd_id%3DLC1K0910N7%26scp_id%3DZ000

      What is the part number for a 3 phase DOL starter for 2.2kW load with overload 4 amps and 415VAC coil??

      The part number for a 3 phase DOL starter with 415VAC coil and overload to cover 4amps is - LE1M35N712

      See attachment.

       

      What is the part number for a 3 pole 32amp 415VAC coil contactor and overload?

      The part number for a 3 pole 32amp 415VAC coil contactor and overload is - LC1D32N7 & LRD32

      For further information , visit links below:-
      https://www.schneider-electric.com.au/en/search/LC1D32N7
      https://www.schneider-electric.com.au/en/search/LRD32

      User-added image

      What is the replacement for a LE1D12N7R05

      The above part is no longer available like this, but is made up of LE1D12N7S48 + LRD05
      3 Pole Reversing and Non Reversing DOL Starters
      Model D DOL Non-Reversing Starters with Overload Purchased Separately
      IP65 Polycarbonate Enclosure (4)
      3-phase 415V AC3 kW: 0.37
      Overload Range A: 0.63 to 1.0
      Overload*: LRD05
      Starter(1)
      *For overload pricing please refer to the Overload Relays section in Power Control and Protection 

      Which rectifier is required for the LX9F*936 380V and 415V coils?

      Issue:
      Which rectifier is required for the LX9F*936 380V and 415V coils?

      Product Line:
      TeSys F-Line Contactors

      Environment:
      All Product Lines

      Cause:
      Can not find it in the Digest

      Resolution:
      For the LX9FJ936, LX9FK936, and LX9FL936 380V and 415V coils, use rectifier part number: DR5TF4S

      What is the part number for LC1D32 contactor with 380V AC Coil?

      The part number for LC1D32 contactor with 380V AC Coil is LC1D32N7.
      Even though the LC1D32N7 has a 415V AC coil the coil has + or -  10% rating making the coil range 373.5 - 456.5V AC which is suitable for 380V AC.

      For more information see:
      https://www.schneider-electric.com/en/product-range-selector/664-tesys-d/?p_url=http%3A%2F%2Fwww.ops-ecat.schneider-electric.com%2Fecatalogue%2Fbrowse.do%3Fel_typ%3Dproduct%26cat_id%3DBU_POW_664_L3%26prd_id%3DLC1D32N7%26scp_id%3DZ000

      What is the part number for an adaptor that will convert 3 phase 415VAC to 240VAC?

      Unfortunately, Clipsal / Schneider do not make an adaptor that would do this.

      Does the 4CNT/63 have a 415VAC coil?

      No. The 4CNT/63 only comes with a 240VAC coil.

      Some of the key features are:
      • DIN rail mount
      • 4 pole
      • 3 module
      • 63 A at AC1

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4CNT4/63
       

      What is the part number for a 3 phase DOL starter with 415VAC coil and overload that has range of 2.6-3.7amps?

      The part number for a 3 phase DOL starter with 415VAC coil and overload that has range of 2.6-3.7amp is - LE1M35N710

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/LE1M35N710
       

      What are the 9013FHG pressure switch contacts rated at?

      Issue:
      Contact Rating of 9013F Pressure Switches

      Product Line: 
      Pressure, vacuum and Float Switches 

      Environment:
      9013 Type F Pressure Switch 

      Resolution:
      Those contacts have a control circuit rating of A600.
      They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
      They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
      They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.

      This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.

      What is the depth of a Clipsal T150F main switch?

      The depth is 81mm including the toggle.
      It is 140mm (H) x 94mm (W)
      The T100 and T150 (front or back wired) range are all the same body size.

      What is the code for a complete LC1D95 with a 415vAC Coil?

         The code for the contactor is LC1D95N7

      What Earth leakage protection relay do i need?

      Firstly Choose from the two types of relays, (DIN rail mount or Front-panel mount) Using the tables below.
      Then make a selection dependent on the voltage required along with the settings desired.


      Vigirex Earth Leakage Protection Relay (DIN rail mount)
      TYPE POWER SUPPLY SETTINGS REFERENCE
      RH21M 12 to 24V AC- 12 to 48V DC 30mA-Inst, 300mA-Insta or 300mA-60ms 56160
        48V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56161
        110 to 130V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56162
        220 to 240V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56163
        380 to 415V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56164
        440 to 525VAC 30mA-Inst, 300mA-Insta or 300mA-60ms 56165
      RH99M 12 to 24V AC- 12 to 48V DC 30mA to 30A- Inst to 4.5s 56170
        48V AC 30mA to 30A- Inst to 4.5s 56171
        110 to 130V AC 30mA to 30A- Inst to 4.5s 56172
        220 to 240V AC 30mA to 30A- Inst to 4.5s 56173
        380 to 415V AC 30mA to 30A- Inst to 4.5s 56174
        440 to 525V ac 30mA to 30A- Inst to 4.5s 56175




      Vigirex Earth Leakage Protection Relay (Front-Panel mount)
      TYPE POWER SUPPLY SETTINGS REFERENCE
      RH21P 12 to 24V AC- 12 to 48V DC 30mA-Inst, 300mA-Insta or 300mA-60ms 56260
        48V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56261
        110 to 130V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56262
        220 to 240V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56263
        380 to 415V AC 30mA-Inst, 300mA-Insta or 300mA-60ms 56264
        440 to 525VAC 30mA-Inst, 300mA-Insta or 300mA-60ms 56265
      RH99P 12 to 24V AC- 12 to 48V DC 30mA to 30A- Inst to 4.5s 56270
        48V AC 30mA to 30A- Inst to 4.5s 56271
        110 to 130V AC 30mA to 30A- Inst to 4.5s 56272
        220 to 240V AC 30mA to 30A- Inst to 4.5s 56273
        380 to 415V AC 30mA to 30A- Inst to 4.5s 56274
        440 to 525V ac 30mA to 30A- Inst to 4.5s 56275
      RHU 220 to 240V AC 15mA to 30A- Inst to 5s 28560(1)

      Then choose a Toroidal to suit:
      Vigirex Sensors (Toroidal and rectangular)
      TYPE DESCRIPTION DIMENSION RATED OPERATIONAL CURRENT REFERENCE
      Closed Toroid,A-type TA30 30mm 65A 50437(2)
        PA40 50mm 85A 50438(2)
        IA80 80mm 160A 50439
        MA120 120mm 250A 50440
        SA200 200mm 400A 50441
        GA300 300mm 630A 50442
      Split Toroid, OA-type POA 46mm 85A 50485
        GOA 110mm 250A 50486
      Rectangular Sensors Small Rectangular Sensors 280 x 115mm 1600A 56053(3)
        Large Rectangular Sensors 470 x 160mm 3200A 56054(3)

      For further information please visit https://www.schneider-electric.com.au/en/


      Vigirex RH10MP-RH21MP-RH99MP-RH197-RHU


       

      What is the DC Bus Voltage Threshold at which the Brake IGBT operates in Altivar 71 Drive powered with 220VAC or 415VAC 3 Phase.

      The Altivar 71 Drive Braking IGBT operates when the value of DC Bus Voltage is higher than the DC Bus Threshold Voltage OBR. When the value of the DC Bus Voltage is lower than the threshold voltage (Unom_max + 10%), the Braking IGBT/Transistor is switched off.

      The Voltage Threshold Values for a Drive working on 220VAC or 415VAC, 3Phase is provided in the attachment.

      Note:

      OBR is the threshold point where the Braking Transistor switches ON and Unom_max + 10% is the threshold point where the Braking Transistor switches OFF.

      PM8000 Frequently Asked Questions

      Issue
      PM8000 Frequently Asked Questions

      Product Line
      PM8000 series meters
      PM8240
      PM8243
      PM8244

      Environment
      Power Monitoring
      Energy Management
      Specification, Functions and Characteristics, Catalog Number, User Guide, Installation Guide

      Issue
      Find the answer to commonly asked questions about the PM8000 as well as user/installation guides for that meter.

      Resolution

      What are the control power input requirements?
      120 to 300 V DC ± 10%
      50/60 Hz ± 10% : 90 to 415 V ± 10%
      Burden:
          Meter only: 18VA max at 415V AC, 6W at 300V DC
          Fully optioned Meter: 36 VA max at 415V AC, 17W at 300V DC

      What is the rating of the current inputs?
      Nominal 5 A (Class 0.2S) or 1 A (Class 0.5S )
      Measured current: 50 mA to 10 A
      Starting current: 5 mA
      Withstand: 20 A continuous, 50 A @10 sec/hr, 500 @ 1 sec/hr
      Impedance: 0.3 mΩ
      Burden: 0.024 VA at 10 A

      What are the voltage inputs rated at?
      Measured voltage: 57 to 400 V L-N / 100 to 690 V L-L (Wye) or 100 to 600 V L-L (Delta or Wye with unearthed neutral)
      Frequency: 50/60 Hz ± 15%,
      400 Hz ± 10%
      Overload: 600 V L-N or
      1035 V L-L

      What are the options to connect the PM8000 via RS485?
      The PM8000 can be connected via RS485 2 wire. The remote display does not have the option to connect RS485 4 wire as the PM800 does.
      in order to communicate RS485 4-wire, a 2 to 4 wire converter needs to be used.

      What are the maximum number of digital and analog inputs on the PM8000 series?
      27 Digital inputs
      16 Analog inputs

      What is the difference between PM8243 and PM8244?
      PM8243 is DIN rail meter with no display.
      PM8244 is DIN rail meter with remote display. The PM8244 is essentially a PM8243 + remote display (PM89RD96) 

      Documentation:
      For additional specifications for your meter and accessories, view the User Manual on page 155-160 (Document # 7EN02-0336-03).
      PowerLogic PM8000 series User manual: https://www.schneider-electric.us/en/download/document/7EN02-0336/

      For specifications related to installation, such as measured voltage and current ranges, inputs/outputs and control power information, View the installation sheet attached on page 7 (Document # EAV47344-03).
      PowerLogic PM8240 installation guide: https://www.schneider-electric.us/en/download/document/EAV47343/
      PowerLogic PM8243 installation guide: https://www.schneider-electric.us/en/download/document/EAV47344/

      For complete specifications and Catalog number, view PM8000 Technical Datasheet attached.
      PM8000 Technical Datasheet: https://www.schneider-electric.com/en/download/document/PLSED310058EN_Web/

      For information on installing the remote display see the PM89RD96 installation sheet.
      PowerLogic PM89RD96 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47345/

      For information on installing the digital and analog option modules see PM89M2600 & PM89M0024 installation sheet.
      PowerLogic PM89M2600 & PM89M0024 installation sheet: https://www.schneider-electric.us/en/download/document/EAV47347/

      For information on the PM8000 Modbus registers see the PM8000 Modbus Map.
      PM8000 Modbus Map: https://www.schneider-electric.com/en/download/document/PM8000_Modbus_Map/
       

      What is the part number for a DOL starter for 7.5kW load with 415VAC coil and overload for 16amps?

      The part number for a DOL starter for 7.5kW load with overload for 16amps is - LE1D18N7 & LRD21

      For further information , visit link below:-
      https://www.schneider-electric.com.au/en/search/LE1D18N7
      https://www.schneider-electric.com.au/en/search/LRD21
       

      Is there a non metallic circuit breaker enclosure available for the Molded Case Circuit Breakers?

      Issue:
      Is there a non-metallic (ie. fiberglass, etc) breaker enclosure for MCCBs?

      Product Line:
      Circuit Breaker Enclosure

      Environment:
      Square D Breaker Enclosure

      Resolution:
      There are no circuit breaker enclosures available for molded case circuit breakers that is manufactured from a non metallic material. Only metal type enclosures are available.
      Show More