screw 5/8x6 nc rsd csk hd

General Accessories Screws, 16mm x M3.5 x 0.8 Pitch, Plated

Catalogue Number: 353B
screw 5/8x6 nc rsd csk hd
Retail
$0.23
RRP (Inc. GST)

Specifications

hide show
Product brand
Clipsal
Thread type
M3.5
Length
16 mm
Shape of screw head
raised countersunk
Package 1 Weight
1 g
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP060307EN

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Specifications

  • Corporate Marketing

Frequently Asked Questions

hide show

What modules support the 140 XSM00200 16 point discrete simulator module connector?

The simulator module connector is designed to operate with the 140DAI 540 00 and the 140 DAI 740 00 modules. These modules are 115 and 230 volts AC and field wire in the same manner. If the power source was reduced to 30volts or less AC the module 140DAI 353 00 could also be used for simulating discrete inputs.


Where can one find technical information on the Powerpact H J and L circuit breakers?

Issue:
Technical information on Powerpact circuit breakers including ratings, accessories, terminations, trip units, trip curves, and dimensions

Product Line:
Circuit breakers

Environment:
Powerpact H, J, and L

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult  product catalog:
Powerpact H/J/L:  0611CT1001
See attachments for trip unit manuals.

For help with Micrologic trip units for Powerpact H, J, and L circuit breakers, including modbus communications, consult instruction manuals:
Powerpact H, J, L Micrologic types 0 1 2 3; see User Guide 48940-310-01
Powerpact H, J, L Micrologic types 5 6; see User Guide 48940-312-01
Powerpact H, J, L modbus communications, see ULP System User Guide 48940-329-01
Modbus™ Communication—User Guide For PowerPact™ H-, J- and L-Frame Circuit Breakers 48940-328-01
PowerPact™ H-, J-, and L-Frame Circuit Breakers Modbus Communication Guide 0611IB1302 

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.
 

Changing counter value while Hot Standby switchover

Goals and Symptoms

This resolution describes a workaround for an effect by a Hot Standby switchover with RIO and a software counter.
The RIO cable connection to the Primary CRP 931 fails.
An input from a 140 DDI 353 00 module has value "1" at the same time.
The Standby system switches to Primary (what is correct).
But the input bit gets for a short time the value "0", because the CRA is not available while switchover.

If the binary input is linked to a software counter the counter will change the value. Also affected are program parts, which use this binary input together with Edge detection.

Facts and Changes

Problem is known with the following components:
Concept 2.6 SR2
140CPU43412A, EXEC 1.25, Kernel 1.01
140CHS11000, EXEC 1.04, Kernel 1.00
140CRP93100, EXEC 1.15, Kernel 1.01
140 DDI 353 00

It should exist with all Hot Standby systems equiped with 140CRP93100, every discrete Input and a software counter or a Edge detection is linked to the Input module.

Causes and Fixes

Use the EN input of the software counter and link it to the healthy bit of the Input module. This avoids to increase the counter during RIO cable interrupt.


Legacy KB System (APS) Data: RESL167770 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Quantum

Information on Powerpact M, P, and R breaker ratings, accessories, terminations, trip units, trip curves, dimensions, and troubleshooting

Issue:
Technical information on MCCB's and their ratings, accessories, terminations, trip units, trip curves, dimensions, application, and troubleshooting

Product Line:
Circuit Breakers

Environment:
Powerpact M P R circuit breakers

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult the product catalogs:
Powerpact M/P/R:  0612CT0101

For help with Micrologic trip units and modbus communications for Masterpact and Powerpact P and R circuit breakers, consult instruction manuals:
Powerpact P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03
Modbus™ Communications System for Micrologic™ A, P, and H Trip Units 0613IB1201
Powerpact P, R, and Masterpact NW, NT Micrologic™ Modbus User Guide 0613IB1313  (Contains information about the currently unavailable IFE Ethernet interface)

For selection information for catalog numbers for breakers and accessories, consult the Parts List:
Masterpact NT and NW:  0613DB1607

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.
 

Technical information on MCCB's and their ratings, accessories, terminations, trip units, trip curves, dimensions, application, and troubleshooting

Product Line:
Powerpact and Masterpact and Legacy circuit breakers

Resolution:
It is possible to find much of the available literature by navigating to it in the Schneider Electric Download Center:
Document Download Center:  https://www.schneider-electric.us/en/download/

If you know the document number you need, you can search by document number in the Download Center tool.
If you do not know the document number, you may find it by searching for keywords.

To find trip curves, ratings, and technical information on electrical and mechanical accessories and lugs, consult the product catalogs:
Legacy MCCB Thermal Mag:  0601CT9101
Legacy MCCB Electronic Trip:  0602CT9201
SE: 0603DB0102
Compact NS:  0615CT9901
Compact NSE: 0621CT9701
Compact CE/CF/CJ: 0600PL9901
Powerpact D:  0616CT0801
Powerpact B: 0611CT1603
Powerpact G: 0500CT9702
Powerpact H/J/L:  0611CT1001
Powerpact M/P/R:  0612CT0101
Masterpact NT/NW: 0613CT0001
Multi 9:  0860CT0201 and LVCATM9OEM_EN​
QO/QOB:  0730CT9801
QOU:  0720CT9401
Powerpact Q:  0734CT0201

For help with Micrologic trip units for Powerpact H, J, and L circuit breakers, including modbus communications, consult instruction manuals:
Powerpact H, J, L Micrologic types 0 1 2 3; see User Guide 48940-310-01
Powerpact H, J, L Micrologic types 5 6; see User Guide 48940-312-01
Powerpact H, J, L modbus communications, see ULP System User Guide 48940-329-01
Modbus™ Communication—User Guide For PowerPact™ H-, J- and L-Frame Circuit Breakers 48940-328-01
PowerPact™ H-, J-, and L-Frame Circuit Breakers Modbus Communication Guide 0611IB1302  (Contains information about the currently unavailable IFE Ethernet interface)

For help with Micrologic trip units and modbus communications for Masterpact and Powerpact P and R circuit breakers, consult instruction manuals:
Powerpact P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
Powerpact P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03
Modbus™ Communications System for Micrologic™ A, P, and H Trip Units 0613IB1201
Powerpact P, R, and Masterpact NW, NT Micrologic™ Modbus User Guide 0613IB1313  (Contains information about the currently unavailable IFE Ethernet interface)

For selection information for catalog numbers for breakers and accessories, consult the Digest and pricing guides:
Compact NS, Multi-9, INS switches, MP Masterpact:  0600PL9701
Masterpact NT and NW:  0613DB1607
QO and QOU:   Square D Digest 177 Section 7
QOB: Square D Digest 177 Section 9
E-Frame: Square D Digest 177 Section 9
Powerpact, Multi-9, Vigirex, GC-200, MCS, MCP:  Square D Digest 177 Section 7
ILINE Breakers: Square D Digest 177 Section 9

For troubleshooting help, consult instruction manuals to ensure proper installation and review troubleshooting help sections where applicable.
Call 888-778-2733 for live help.