30mos 1/2 way mech - outside

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, OUTSIDE

Catalogue Number: 30MOS
30mos 1/2 way mech - outside
Retail
$27.5*
RRP (Inc. GST)
Colour White Electric (WE)
  • White Electric 1 PCE
  • Cream 1 PCE

Specifications

hide show
Range of product
  • Standard Series
  • Series 30
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
      2-way
      Actuator
      rocker
      Number of rocker
      1
      Device mounting
      flush
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      outside
      Marking location
      marking on surface
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Which Clipsal 30 Series mechs are available in 3S (Chrome Shadow)

      Part codes which are available in 3S -  30M, 30USM, 30MI, 30MD, 30MBPR, 30M35, 32E450UDM, 32E450LM, 32E450TM 

      The Clipsal 30M20 is discontinued, What is the alternative part?

      The alternative part for the Clipsal 30M20 is the 30USM: Universal Rocker Switch, 1-Way/2-Way, 250VAC, 20A.
       

      What is the part number for a 30 series switch mech , labelled ZONE 1 , 2 , 3 ?

      The part number for a 30 series switch mech , labelled ZONE 1 , 2 , 3 is - 30MZ1 , 30MZ2 , 30MZ3
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=30MZ1

      Do you have a 2 pole RCD 40A 30mA?

      Yes the part number is RCD240/30.

      What is the din rail mounted timer - wanted to time for 30mins

       The part code is 16066

      What Saturn Zen 2 gang plate accommoddates 30m35 mech?

      The Saturn Zen 2 gang  plate accommoddates 30m35 mech is Z4032VH.

      Can part number 30M35 be used in 2031V66?

      No. Unfortunately, part number 30M35 CANNOT be used in 2031V66.

       

      What is the life cycle of the 30MBP?

      The 30MBP has been tested to 12000 cycles.

      How to set the IO Board Parameters in Scadapack Workbench?

      The module_address parameter defines the module address of the sp5607 I/O module.

      The address on the module is selected via dip switches on the module. A maximum of eight SCADAPack 5607 I/O type modules may be added to a system

      The ain0_type parameter sets the analog input type for analog input channel 1.

      There are four input types available.

      • An ain_type of 0 sets the input type to measure 0 to 5V input signals.
      • An ain_type of 1 sets the input type to measure 0 to 10V input signals.
      • An ain_type of 2 sets the input type to measure 0 to 20mA input signals.
      • An ain_type of 3 sets the input type to measure 4 to 20mA input signals.

      The ain_filter Parameters:

      • An ain_filter value of 0 sets the input filter for 3Hz and the response time to 155ms at 60Hz and 185ms at 50Hz.
      • An ain_filter value of 1 sets the input filter for 6Hz and the response time to 85ms at 60Hz and 85ms at 50Hz.
      • An ain_filter value of 2 sets the input filter for 11Hz and the response time to 45ms at 60Hz and 55ms at 50Hz.
      • An ain_filter value of 3 sets the input filter for 30Hz and the response time to 30ms at 60Hz and 30ms at 50Hz.

      The scan_freq parameter sets the input scan rate for analog inputs. AC noise rejection is improved at the correct frequency. If the module is used in a DC environment, the 60 Hz setting will yield slightly faster response time.

      • A scan_freq value of 0 synchronizes the input scanning to 60Hz.
      • A scan_freq value of 1 synchronizes the input scanning to 50Hz.

      The aout_type parameter sets the analog output type for both optional analog output channels.

      • An aout_type value of 0 sets the output type for 0 to 20mA signals.
      • An aout_type value of 1 sets the output type for 4 to 20mA signals.


      Is part number 30MAM available in 15amp?

      The part number is a - 30MAM15

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MAM15


      User-added image

      Can a Clipsal 30MD20 be used as a changeover switch?

       No - It is just a 2 pole switch
      But a 30MD2 is a 2p 2way (6 terminals)

      Is there a Double Pole mech in the Saturn range?

      No, but you can use a 4031VH and a 30MD.