Standard Range, Flush Switch, 1 Gang, 2 Pole, 250VAC, 10A, Architrave

White Electric | Standard Range, Flush Switch, 1 Gang, 2 Pole, 250VAC, 10A, Architrave

Standard Range, Flush Switch, 1 Gang, 2 Pole, 250VAC, 10A, Architrave

Item Number: 30D-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element with full cover plate and grid

Switch function

2-pole

Number of rocker

1

Number of poles

2

Device mounting

flush

Fixing mode

by screws

Local signalling

without

[Ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Actuator

rocker

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Compliant

Mercury free

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

RoHS exemption information

Yes

Environmental Disclosure

ENVPEP120506EN

Others

Package 1 Bare Product Quantity

1

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

3 cm

Package 1 Width

3 cm

Package 1 Length

7.5 cm

Package 1 Weight

31 g

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Height

7.8 cm

Package 2 Width

8.8 cm

Package 2 Length

17 cm

Package 2 Weight

372 g

Unit Type of Package 3

CAR

Number of Units in Package 3

250

Package 3 Height

23.8 cm

Package 3 Width

34.2 cm

Package 3 Length

39 cm

Package 3 Weight

10 kg
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Technical Data Catalogues

Frequently Asked Questions

hide show

Is the ATV630 (or ATV930) Process drive available with 1 phase input and 3 phase output?

Issue:
Are the Process drives available with single phase input and 3 phase output?

Product Line:
Altivar 630
Altivar 930

Environment:
Application 

Cause:
Wants to know if the ATV630 Process drive is offered in 1 phase input 3 phase output. 

Resolution:
The ATV630 is approved for some single phase input, 3 phase output applications. 
See the current Annex to the Getting Started with Altivar Process ATV600 document below:
https://www.schneider-electric.com/en/download/document/EAV64300/

This document lists models for 240V and 480V Pump applications.
Note: Do not use ATV630D55M3 and ATV630D75M3 for 1-phase application.

At this time, no ATV900 Process drives are approved for single phase supply.  They are designed strictly for 3 phase input power to run a 3 phase motor.

The ATV900 series may be used in conjunction with a 3rd party input bridge from a company like Bonitron (Bonitron Solutions for Schneider Drives) .
Contact Bonitron directly for assistance.

Are conduit kits available for the Altivar Process Drives?

Issue:
Conduit kits for the Altivar Process Drives

Product Line:
Altivar Process Drive (ATV630, ATV930)

Environment:
All serial numbers for Altivar Process Drive

Cause:
N/A

Resolution:
Frame Size 1...4
  • Includes IP21 conduit kit already installed on the drive
Frame Size 5
  • Includes IP21 conduit kit but not installed on the drive
Frame Size 6, 7A and 7B 
Conduit kits are not supplied and have to be ordered:
  • Size 6 [ATV630D55M3, ATV630D75M3, ATV930D55M3C, ATV930D75M3C, ATV630C11N4, ATV630C13N4, ATV630C16N4, ATV930C11N4C, ATV930C13N4C, ATV930C16N4C]
    • UL type 1 and IP21: VW3A9704
  • Size 7A [ATV630C22N4, ATV930C22N4(C)]
    • UL type 1: VW3A9212
    • UL type 21: VW3A9112
  • Size 7B [ATV630C25N4, ATV630C31N4, ATV930C25N4C, ATV930C31N4C]
    • UL type 1 without braking unit: VW3A9213
    • UL type 1 with braking unit: VW3A9214
    • UL type 21 without braking unit: VW3A9113
    • UL type 21 with braking unit: VW3A9114



 

Models of Pelco cameras that have been tested with version 3 NetBotz and BotzWare 4.X

Issue:
Models of Pelco cameras that have been tested with version 3 NetBotz and BotzWare 4.X

Product Line:
NetBotz
Pelco Cameras

Environment:
NetBotz NBWL0455 and NBRK0570 
4.X botzware
Pelco camera support

Cause:
Not all Pelco cameras have been tested with NetBotz 4.0 botzware.

Resolution:

Please note that the NetBotz 3xx and NetBotz NBRK0450/0451 do not support the Pelco integration.


The initially supported Pelco cameras from version 3.x firmware are:
 
Pelco Camera ModelProduct FamilyFirmware Version Tested
IP3701H-2IPUnavailable
IP110-CHV9IP110 Camclosure®Unavailable
SD4N-W0Spectra Mini IPUnavailable



The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.0. The Sarix line of Pelco cameras have been added to testing:
 
Pelco Camera ModelProduct FamilyFirmware Version Tested
IXS0CSarix IX1.7.19.9080-A1.5842
IXE20DNSarix Enhanced1.7.19.9081-A1.5843
IX30DNSarix IX1.7.8.9080-A1.5288
IMSOC10Sarix IME1.7.41.9260-O2.6725
SD4N-W0Spectra Mini IP 1.2.15

 
With the release of Botzware 4.2, the following list of additional Pelco cameras and firmwares have also been tested:
 
Pelco Camera ModelProduct FamilyFirmware Version Tested
IMSOC10Sarix1.8.2
IM10C10Sarix1.8.2
IX30DNSarix IX1.8.2
D5118Spectra HD1.8.2
TXB-NSpectra IV IP1.8.2
DD4N-W0Spectra Mini IP1.2.15
IP110IP110 Camclosure®1.0.47
IP3701IP1.0.10

The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.4:
 
Pelco Camera ModelProduct FamilyFirmware Version Tested
IM10C10Sarix1.9.2
IMS0C10Sarix1.9.2
D5118 Spectra HD1.9.2
IME119Sarix Enhanced2.1.2.0.8280-A0.0

The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.5.3:
Pelco Camera ModelProduct FamilyFirmware Version Tested
IL 10SarixUnavailable
 
The following is a list of cameras and Pelco firmware that has been tested with BotzWare version 4.6.3:
Pelco Camera ModelProduct FamilyFirmware Version Tested
IJP121-1ISSarix1.16.37
 

Important Note:

Pelco Sarix Pro models that were originally listed as supported do not correctly update the resolution settings presented to NetBotz appliances. NetBotz can no longer support Sarix Pro models due to this limitation of the Pelco camera and they have been removed from this compatibility matrix.

 
 
 

What is the maximum cable size in mm² for terminating into the earth and neutral links in the 230DRAVL meter box?

The maximum cable core size for  is 10mm² for 5mm diameter tunnels  and the maximum cable core size 35mm² for 8mm diameter tunnels in both earth and neutral links. The cable entries into the box are 2 x 50/40mm diameter knockouts and 1 x 20mm diameter knockout.

image.png

image.png

How does Multidrive link grouping works on ATV Process drives?

In case of drives ATV600 it is possible to use several Multidrive Link groups by configuring MDPC parameter for each group. It is also possible to add individual drives to the same network.


In case of ATV900 it is not possible to use more than one group in the same network. but individual drives can be used in the same network as the multidrive link group.
A simple switch can be used for this kind of application.
 

Can I use VW3A3316 Communication card in ATV61/71 for Modbus TCP?

VW3A3316 has not been validated for Modbus TCP communication. For Modbus TCP communication we recommend using VW3A3320 Ethernet IP/Modbus TCP comms module.  
 