switch mech 1/2w 10a cool

Switch Mechanisms, 30 Series, 10A Mechanisms - Marked, COOL

Catalogue Number: 30COM
switch mech 1/2w 10a cool
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Series 30
  • Standard Series
    • Product brand
      Clipsal
      Device presentation
      basic element
      Switch function
      2-way
      Actuator
      rocker
      Number of rocker
      1
      Number of poles
      1
      Device mounting
      flush
      Local signalling
      without
      [Ue] rated operational voltage
      250 V AC
      Rated current
      10 A
      Marking
      cool
      Marking location
      marking on surface
      Sustainable offer status
      Green Premium product
      REACh Regulation
      Reference contains Substances of Very High Concern above the threshold
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information
      Environmental Disclosure
      ENVPEP120506EN
      Circularity Profile
      N/A

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Technical Leaflet

      • Installation Instruction

      • Specifications

      • Certificates (MSDS)

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Saturn - is there an option for banana mechanisms in this range?

      YES - 30BCRM OR 30BCBM OR both in a 4031 or 4032 Communication plate.

      What is the part number for a speaker cable mechanism?

      The part number for a speaker cable mechanism is a 30BCBM for black and a 30BCRM for red.
       

      Is there a 15A Surge protected outlet?


      To obtain a surge protected 15A outlet you will need to purchase a C2015/15X and a 30SFM and replace the extra switch in the outlet with the 30SFM surge protector mechanism and then wire accordingly.
      For some reason we have given the 30CSFM a 10A rating. The mechanism only needs to be rated for the correct voltage and correct fault current the amperage rating is irrelevant as this device does not have the load passing through it, it is there merely for fault conditions.

      What is the part code for a back plate from the Gael range dimensions 610 x 305mm

       The part code is BP24/12

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Goals and Symptoms

      Difference between the 'STBXCA1003' or 'LU9RCD03' cable.

      Facts and Changes

      Advantys Configuration software.

      Causes and Fixes

      The pinouts for both cables are identical. The only difference is the type of connector that is used on
      the end of the cable and the length of the cable. The 'LU9RCD03' uses a straight connector and an
      angled connector and is 30cm long. The STBXCA1003 uses two angled connectors and is 4.5m long.
       


      Legacy KB System (APS) Data: RESL198335 V1.0, Originally authored by AlCh on 05/04/2009, Last Edited by AlCh on 05/04/2009
      Related ranges: Advantys STB

      If 755RPL is wall mounted, what is the minimum distance it can be from the ceiling?

      When wall mount the 755RLPSMA2, the minimum distance it can be mounted from the ceiling is 30cm with a maximum of 50cm.
      Some of the key features are:

      • New look design with easy to use test/hush button
      • Sealed-in rechargeable lithium backup battery
      • Quality optical chamber with stainless steel insect screen
      • Easy installation and maintenance
      • Wired interconnect feature (up to 40 alarms)
      • Optional relay or wireless interconnect bases
      • Backwards compatible with 755PSMA and 755SMA mounting bases
      • Robust digital design


      For further information please visit www.clipsal.com/Trade/search-results?q=755RLP

       

      Will the 30RSM mechanism fit into a Saturn plate?

      No, unfortunately this mechanism does'nt fit the Saturn series. However, this mechanism will fit into the coms Saturn series comunication plate 4031VH.

      What is the part code for a sky connection 30 series mech

       Part code 30PFM

      What is the part code for a Clipsal Telephone Mech

       The part code is 30BTM

      Is part number 30MAM available in 15amp?

      The part number is a - 30MAM15

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30MAM15


      User-added image

      What is the F type connector plates with dual outlets

      Not available as complete.  Use 2 x 30PFM and a 2 gang plate

      What is the part code for TV mechs 30 series - F type front and back

      Use a 30PFM mech

      What parts are required to make a Saturn permanent connection unit (PCU)?

      4032VH + 30USM + 38TB

      Is part number 30USM Double pole?

      No, part number 30USM is not a double pole.

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USM


      User-added image

      Are the keys available for part number 30TKM?

      The keys for part number 30TKM are only available as a special.
      We don’t do them as a standard part.

      Is the 30BTM Clipsal Telephone Mechanism available in Black ?

      No, Not Available in Black 

      What does the Clipsal BT 2 Wire Telephone Mechanism (30BTM) look like?

      please follow the limk

      What is the part number for our 300mm ex-fan?

      The part number for Clipsal 300mm ex-fan is - 6230-0

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=6230-0
      User-added image

      What is the part number for a 300mm ceiling exhaust fan?

      The part number for a 300mm ceiling exhaust fan is - 6230-0

      For further information, visit the link below:-
      https://www.clipsal.com/Trade/search-results?q=6230-0
      User-added image

      Register Map for the MiCOM P14x

      Issue   
      Need the register list/map for the MiCOM P14x

      Product Line  
      MiCOM P141
      MiCOM P142
      MiCOM P143
      MiCOM P144
      MiCOM P145

      Resolution   
      The following link is all the MiCOM P14x register maps.  It is also known as the Menu Database.
      https://www.schneider-electric.com/en/download/document/P14x_MD/

      Register Map for the MiCOM P34x

      Issue   
      Need the register list/map for the MiCOM P34x

      Product Line  
      MiCOM P342
      MiCOM P343
      MiCOM P344
      MiCOM P345
      MiCOM P391

      Resolution   
      The following link is all the MiCOM P34x register maps.  It is also known as the Menu Database.
      https://www.schneider-electric.com/en/download/document/P34x_MD__P341_P342_P344_P345_P391/

      Is the capacitor of 30CSFM sold separately as a spare?

      The capacitor is not sold separately.

      Is the PDL 682 available in a keylock version

      Not available, you can use the Clipsal 30TKM this can be fitted in a single VH plate (C2031VH)

      Can the 30TKM be installed in any Clipsal range of switch plates?

      Yes, it can be installed in any switch plate that will take a 30 series mechanism.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30TKM 


      Can the 30TKM be installed in any Clipsal range of switch plates?

      Yes, it can be installed in any switch plate that will take a 30 series mechanism.

      For more information, please refer to the link:
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30TKM 

      Do you sell the 30CSFM mech on its own (less capacitor)?

      No, however we do sell a 30RSM3 which is a 3 position switch. it looks entierly different how ever it has the same operating characteristics.

      What is the part number for a mounting block that can be mounted on a circular 300mm pole?

      The part number for a mounting block that can be mounted on a circular 300mm pole is - 2000MF300
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=2000MF300

      User-added image

      What is the phone and permanent connection mechs for the Clipsal Slimline plates

      Slimline fits all 30 Series mechs.  Permanent connection unit is the 38TB, phone mech is 30BTM

      Which mechs fit the Clipsal BSL Range ?

      Any 30 series Clipsal mech will fit.  30BTM is the telephone mech, available in white only.  30FFPFMS is the TV mech.

      What data and telephone jacks do we have to suit Saturn series

      You can use 4030VH plates and the 30 series mechs i.e. VDIB17735U, VDIB17756U, VDIB17736U & 30BTM

      Is there a "Draftstoppa" to suit the 6500A?

      No. Our Draftstoppa only suits round exhaust fans up to 300mm diameter.

      MiCOM P64x Manuals

      Issue
      Need MiCOM P64X Manuals

      Product Line
      MiCOM P64x

      Resolution
      Manuals for MiCOM P64x refer to the Document Center for the most up-to date documents for your specific MiCOM device: https://www.schneider-electric.ca/en/search/MiCOM+P64x+Manual 


      What are the deviation of measurements in MICOM P127 relay ?

      The details for the deviation in standard measurement of the relay and optional measurement with CT (Current Transformer) is attached.

      Register Map for the MiCOM P24x

      Issue   
      Need the register list/map for the MiCOM P24x

      Product Line  
      MiCOM P241
      MiCOM P242
      MiCOM P243


      Resolution   
      The following link is all the MiCOM P24x register maps.  It is also known as the Menu Database.
      https://www.schneider-electric.com/en/download/document/P24x_MD/

      Register Map for the MiCOM P44x

      Issue   
      Need the register list/map for the MiCOM P44x

      Product Line  
      MiCOM P441
      MiCOM P442
      MiCOM P444


      Resolution   
      The following link is all the MiCOM P44x register maps.  It is also known as the Menu Database.
      https://www.schneider-electric.com/en/download/document/P44x_MD/

      What is the part number for strip cable 300MM X 15MTR?

      The part number will be 287R300HD15-EO.
      For more information please follow the below link:
      https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=287R300HD15

       

      What is the part code for a Clipsal metal range 12 Gang Switch Assembly (Less Mechanisms) - Stainless Steel?

      B12/30/6 = 12-Gang Switch Plate. 2 rows of 6. Stainless steel. 303mm 120mm
      12/30/162/3 = 12-Gang Switch Plate. 4 rows of 3. Stainless steel. 165mm 215mm

      Includes stainless steel fascia with grid and wall box. Standard grid colours - White Electric (WE) and Black (BK).
       

      Can I get a 30USM with a red dot on the dolly?

      Yes, you can get a 30USM with a red dot. The part number is 30USMRD.

      Some of the key features are:
      • Reduced visible arcing and crackling
      • Modular 30 mech design suits most Clipsal switch plates
      • With Red Dolly dot
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USMRD


       

      What is the part number for knob to suit a 30CSFM?

       The knob part number for a 30CSFM is  2031VF3CB-KB-**.
      ** - required colour of the knob.

      For more information on this product range please visit the Clipsal.com website on the link provided
      https://www.clipsal.com/Trade/search-results?q=2031vf3cb-kb
      https://www.clipsal.com/Trade/search-results?q=30CSFM

      Is the 30CSFM fan speed controler solid state?

      No, the 30CSFM is not solid state it has a foil type capacitor.

      Some of the key features are:
      • For ceiling sweep fan
      • 75 VA Maximum load
      • Speed control technique: Capacitive attenuation

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30CSFM
       

      Can the 30USM be used for Fluro loads?

      Yes , it is rated to 16AX for fluro based loads.

      Is a 30USM-WE a normal switch rocker mechanism

      30USM-WE = Universal switch mechanism 20/16AX - compared to the 10A only 30M-WE
      (see attached 30USM Brochure)

      What is the size of the terminal screws in the Clipsal 30USM mech?

      Screw B.S M3.5 X 0.6, 5.6mm CH HD IN

       

      Is a 16amp mech available marked 'Heat'?

      Part number replaced with 30USM mech but marked 'Heat' is not standard.
       

      Where to find settings manual for MiCOM x3x Series?

      Issue 
      Need more information on settings on the MiCOM x3x.

      Product Line  
      MiCOM P13x
      MiCOM P23x
      MiCOM P43x
      MiCOM P53x
      MiCOM P63x

      Environment  
      Setting or Troubling settings

      Resolution    
      All the settings, measurements, recordings with option and configuration tables plus IEC - 103 telegram documentation/menu database can all be found in the Data Model Explorer.
      To get the Data Model Explorer needed just type in the MiCOM model need.  For example in Google type in MiCOM P438 for Data Model Explorer.  Click on the Schneider Electric result for the MiCOM P438 Data Model Explorer.
      It will bring up the following Data Model Explorer page https://www.schneider-electric.com/en/download/document/P438_DataModelExplorer_EN/
      On the site download the P438 that is needed. 
       

      Is there a way to block off my 300mm exhaust fan when not in use?

      Yes, you can use a Draftstoppa. The part number is CEDS1.

      Some of the key features are:
      • Draftstoppa prevents heating / cooling escaping through all non-operating domestic ceiling exhausts up to 300 mm.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=CEDS1.
       

      Can you wire an over ride into a 2 wire 750WP?

      Yes. In order to get the system to work, you will need to wire in either 2x 30M's or a 30MAM into a wall plate and connect to the sensor.

      For further information on the sensor, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=750WP

      User-added image

      What is Micom Z-Graph Software and where can it be download it from?

      Issue
      What is Micom Z-Graph Software and where can it be download it from?

      Product Line
      Micom P440

      Environment 
      Microsoft Windows/ Micom S1 Studio

      Cause
      Unable to find Micom Z-Graph software and its documentation.

      Resolution
      Micom Z-Graph software allows downloading distance protection settings from the relay and displaying the tripping characteristic for all 4 groups. The user can modify the distance settings and upload the new configuration into the relay. Conversion to Rio Format, and an Expert Tool for analysis is available. This software only works with Micom P442 Relay.




      The software can be download from BOX at the link below:
      https://schneider-electric.box.com/s/8o6oamed3c0li9eln30rh805sc2njo2p

      I am looking for a wall fan with a 240mm cutout and is physically approx 300mm square

      You can use a Clipsal 7106A or 7108A both have a 230mm cut out and are 271mm square

      How to connect a MiCOM P111 to MiCOM S1 Studio

      To connect a MiCOM P111 to MiCOM S1 Studio, a RS-485 to RS-232 converter must be used. The MiCOM P111 only has a two-wire RS-485 port and this must be converted to RS-232 to connect to a PC in order to use MiCOM S1 Studio.


      Legacy KB System (APS) Data: RESL211663 V1.0, Originally authored by DaFr on 06/04/2013, Last Edited by DaFr on 06/04/2013
      Related ranges: Others protection relays

      AEDL3
      Show More