Quantcast

Clipsal Iconic Flush Switch Vertical Mount, 2 Gang, 250V, 10AX, LED

Vivid White | Clipsal Iconic Flush Switch Vertical Mount, 2 Gang, 250V, 10AX, LED

Clipsal Iconic Flush Switch Vertical Mount, 2 Gang, 250V, 10AX, LED

Item Number: 3042AL-VW

Build this product i

Retail
$50.16
RRP (Inc. GST)

The Clipsal Iconic Flush Switch is an ideal solution for installations in tight spaces. Frequently used to fit the mouldings surrounding door frames, the smaller size of this flush-mount 2-way light switch makes it perfect when space is limited.

Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width38 mm

Height icon

Height120 mm

Depth icon

Depth39 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-
Clipsal Iconic 3025 exploded view
3043G Rear Perspective

Specifications

Design

Range

Clipsal Iconic

Product or component type

switch

Device application

lighting

Colour tint

vivid white

Physical

Quantity per set

set of 20

Device presentation

complete product

Control type

rocker

Device mounting

flush

Installation direction

vertical

Switch function

1-pole 1/2-way

Number of rocker

2

Local signalling

LED indicator

Rated current

10 A

[Ue] rated operational voltage

250 V

Height

120 mm

Width

38 mm

Depth

39 mm

Net weight

0.05 kg

REACh Regulation

Reference contains Substances of Very High Concern above the threshold

EU RoHS Directive

Not compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

ENVPEP120506EN

Material

Material

plastic

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

30 g

Package 1 Height

48 mm

Package 1 width

55 mm

Package 1 Length

149 mm
Show all specifications

Frequently Asked Questions

hide show

What are the dimensions of a 4061AL or 4062AL plate ?

The plate dimensions are the same for 1 gang and 2 gang saturn architrave
97mm Hx 38mm W

What is the part number for a 2 gang Iconic switch plate and switch mech and dimmer?

The part number for a 2 gang Iconic switch plate and switch mech and dimmer is - 3042HA , 40M & 41E300PBUD2SM

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3042HA
https://www.clipsal.com/Trade/search-results?q=40M
https://www.clipsal.com/Trade/search-results?q=41E300PBUD2SM
User-added image

What can cause an USF (undervoltage fault) on an ATV12 drive?

Issue: 
USF (undervoltage fault) on an ATV12 drive.

Product Line:
Altivar 12

Environment:
All

Cause:
Fault condition

Resolution:
For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. 
For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals.

Recommendations:
- Measure the the incoming line to line voltages
- Compare the line voltage to the Mains Voltage as shown under monitoring MON.
- If the standard line voltage is low, you can adjust the Mains voltage setting
- Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur. 
- Check to issues where line potential is dropping due to supply issues that may be caused by load pulling too much current.

What are the causes of an USF fault on ATV61/ATV71 drives?

Issue:
Causes of an USF fault on ATV61 drives.

Product line:
ATV61, ATV71, Altivar 61, Altuvar 71

Environment:
All models

Cause:
Undervoltage supply.

Resolution:
The USF fault occurs when the DC bus voltage level drops below the threshold set in 1.8 Fault Management > Undervoltage Management > Undervoltage level. 

For N4, 480V drives at factory setting of 480VAC, the threshold is 430VDC on the DC bus or 304VAC on the line terminals. 
For M3, 240V drives at factory setting of 260VAC, the threshold is 230VDC on the DC bus or 163VAC on the line terminals.
For Y, 575V drives at factory setting of 690VAC, the threshold is 571VAC on the DC bus, or 404VAC on the line terminals.

Recommendations:
- Measure the the incoming line to line voltages
- Compare the line voltage to the Mains Voltage as shown under Menu 1.2 Monitoring, and also the measurement of the DC bus voltage.
- If the standard line voltage is low, you can adjust the Mains voltage setting.
- Adjust the Undervoltage time out to compensate for line contactors, or add time delay before a fault would occur. 
 
Exploded view of the Clipsal Iconic skins range; Styl, essence and Standard.

Range

Customisable and future-ready

Iconic is based around a unique, electrically safe grid plate, with a choice of three different skin designs that simply clip on top.

Once the grids have been installed by an electrician, it’s safe for anyone to change the skins at any time. Simply clip off the standard skins and clip on the new design.

Interchangeable standard, Styl and Essence skins provide great options to customise to suit specific decor and lifestyle.