Clipsal Iconic Switch Vertical, 1 Gang, 1/2 Way, 10AX, 250V, IP44

Vivid White | Clipsal Iconic Switch Vertical, 1 Gang, 1/2 Way, 10AX, 250V, IP44

Clipsal Iconic Switch Vertical, 1 Gang, 1/2 Way, 10AX, 250V, IP44

Item Number: 3041V44-VW

Build this product i

Retail
$51.26
RRP (Inc. GST)
Colour Vivid White (VW)
  • Vivid White 1 PCE

Product Dimensions

Width icon

Width82 mm

Height icon

Height124 mm

Depth icon

Depth40 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Clipsal Iconic

Product or component type

switch

Device application

lighting

Colour tint

vivid white

Physical

Quantity per set

set of 20

Device presentation

complete product

Control type

rocker

Device mounting

flush

Installation direction

vertical

Switch function

1-pole 1/2-way

Number of rocker

1

Rated current

10 A

[Ue] rated operational voltage

250 V

Height

124 mm

Width

82 mm

Depth

40 mm

Net weight

0.098 kg

IP degree of protection

IP44

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Material

Material

plastic

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

80 g

Package 1 Height

39 mm

Package 1 width

78 mm

Package 1 Length

120 mm

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Weight

964.6 g

Package 2 Height

328 mm

Package 2 width

106 mm

Package 2 Length

146 mm

Unit Type of Package 3

CAR

Number of Units in Package 3

50

Package 3 Weight

5208.2 g

Package 3 Height

335 mm

Package 3 width

261 mm

Package 3 Length

335 mm
Show all specifications

Frequently Asked Questions

hide show

Does part number 3044V44 available in Cool Grey?

Part number comes standard as Vivid White, will need Cool Grey cover to suit.
 

What is the part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates?

The part number for the 1 gang Iconic switch , and can the mech be rotated for horizontal or vertical switch plates - 3041VA and yes can be mounted Vertical or Horizontal..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3041VA
User-added image

Is there a horizontal version of Iconic 3041/45, single pole 250V, 45A cooking appliance isolator?

3041/45, single pole 250V, 45A cooking appliance isolator can be vertical or horizontal mounted. However the mechanism orientation cannot be changed.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=3041/45

Do we have any series ratings with the Masterpact NT and NW breakers?

Issue:
Do we have any series ratings with the Masterpact NT and NW breakers?

Product Line:
Masterpact NW, NT

Environment:
Masterpact breakers in NEMA markets

Resolution:
There are no series ratings for Masterpact NT, NW circuit breakers.
There are none for the obsolete SE or Masterpact MP either.
 

How many lugs are included in the DASKP400?

Issue:
Transformer lug kits

Product Line:
LV Transformers

Environment:
Applies to Low Voltage Transformers by SquareD/Schneider Electric

Cause:
Transformers 15 KVA and over may require lug kits

Resolution:
Lug kits can be found in the online Catalog 7400CT0501. 
This kit includes 3 lugs per kit
See attached.
 

What is the percentage of imbalance that will cause a single phase sensitive D-line overload to trip?

Issue:
Identifying trip point in a single phase sensitive overload relay

Product Line:
NEMA combination starters

Environment:
Products sold and used in the United States

Cause:
Identifying the trip point in a single phase sensitive Tesys D overload relay

Resolution:
The phase loss sensitive overloads are designed to conform to IEC standard 60947-4-1. In that standard is this paragraph:

8.2.1.5.2 Limits of operation of three-pole thermal overload relays
energized on two poles
With reference to table 4:
The overload relay or starter shall be tested in its enclosure if normally fitted. With the relay
energized on three poles, at A times the current setting, tripping shall not occur in less than
2 h, starting from the cold state, at the value of the ambient air temperature stated in table 4.
(Table 4 `A` multiple of current setting states 2 poles at 1.0 times the current setting, the third pole at 0.9)

Moreover, when the value of the current flowing in two poles (in phase loss sensitive relays,
those carrying the higher current) is increased to B times the current setting, and the third
pole de-energized, tripping shall occur in less than 2 h. (Table 4 `B` multiple of current setting is 2 poles
at 1.15 current setting, third pole at 0.0.)

The values shall apply to all combinations of poles.

In the case of thermal overload relays having an adjustable current setting, the characteristics
shall apply both when the relay is carrying the current associated with the maximum setting
and when the relay is carrying the current associated with the minimum setting.