Clipsal Iconic Switch Plate Skin Blank, Horizontal/Vertical Mount

Clipsal Iconic Switch Plate Skin, Blank, Horizontal/Vertical Mount

Clipsal Iconic Switch Plate Skin Blank, Horizontal/Vertical Mount

Item Number: 3040C-VW

Retail
$9.72
RRP (Inc. GST)
Colour Vivid White (VW)
  • Vivid White 1 PCE
  • Anthracite 1 PCE
  • Cool Grey 1 PCE
  • Warm Grey 1 PCE

Product Dimensions

Width icon

Width78 mm

Height icon

Height120 mm

Depth icon

Depth9 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-
Clipsal Iconic 3025 exploded view
3043G Rear Perspective

Specifications

Design

Range

Clipsal Iconic

Product or component type

cover frame

Physical

Quantity per set

set of 20

Device mounting

flush

Fixing mode

clip-on

Installation direction

horizontal/vertical

Height

120 mm

Width

78 mm

Depth

9 mm

Net weight

0.02 kg

EU RoHS Directive

Under investigation

Environmental Disclosure

ENVPEP120506EN

Others

Package 1 Weight

22 g

Package 1 Height

9 mm

Package 1 width

83 mm

Package 1 Length

125 mm
Show all specifications

Frequently Asked Questions

hide show

Is Iconic intermediate mechanism available assembled on a switch plate?

Unfortunately, the Iconic intermediate mechanism is not available assembled on a plate. It can put together using below part numbers;
40MIL  - Clipsal Iconic Intermediate Switch Mechanism, 250V, 10A, LED.
+
3041G - Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang
+
3041C - Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang
For further information, please visit the below links:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MIL
https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G
https://www.clipsal.com/Trade/search-results?q=3041C


What does the PDLDBF30BPDOM consists of

 It comes with 1xDBF30, 3x40A RCCBs, 7x20A MCBs, 2x10A MCBs

What is the Pin out detail for the Modbus programming cable 110 XCA 20 3000?

The pin out details of the Modbus programming cable 110 XCA 20300 is as shown in the attached.

 

What is the Maximum number of BMXNOR0200 module which can be installed with a Modicon M580 CPU local rack.

The maximum number of BMXNOR0200 which can be installed within a local rack containing M580 CPU is 6.
It also depends on the model of M580 CPU is being used.

1. BMEP58 6040 can accomodate 6 BMXNOR0200 modules.
2. BMEP58 5040 can accomodate 4 BMXNOR0200 modules.
3. BMEP58 4040 can accomodate 4 BMXNOR0200 modules.
4. BMEP58 4020 can accomodate 4 BMXNOR0200 modules.
5. BMEP58 3040 can accomodate 3 BMXNOR0200 modules.
6. BMEP58 3020 can accomodate 3 BMXNOR0200 modules.
7. BMEP58 2040 can accomodate 2 BMXNOR0200 modules.
8. BMEP58 2020 can accomodate 2 BMXNOR0200 modules. 
9. BMEP58 1020 can accomodate 2 BMXNOR0200 modules. 

What is the new part numbers for the Clipsal 9040CM and 9050CM conduit

New part numbers are 9040TCM and 9050TCM
Now changed to the Turbo version.

What is the maximum Modbus port speed on the M340 CPU?

Modbus port speed up to 38400 baud on all CPU's with embedded Modbus ports. (ex. BMXP341000, BMXP342000, BMXP342010, BMXP342020)


What are the replacement parts needed to make up a XACA871 Pendant Station

 XACA08 x 1  EPTY PNDANT CONTROL STATION XACA 8 VER + ZB2BY2307 x 1 LEGEND 30 X 40 MM BLACK UP + ZB2BY2308 x 1  
LEGEND 30 X 40 MM BLACK DOWN + ZB2BY23EA x 1 LEGEND PL EAST 30X40 + ZB2BY23WE x 1 LEGEND PL WEST 30X40 + ZB2BY23NO x 1
LEGEND PL NORTH 30X40 + ZB2BY23SO x 1 LEGEND PL SOUTH 30X40 + ZB2BY2303 x 1 LEGEND 30 X 40 MM BLACK START + ZB2BY2931
x 1 LEGEND 30 X 40 MM RED 0 + ZB2BE101 x 7 SPRING RETURN CONTACT BLOCK 1 NO + ZB2BE102 x 1 SPRING RETURN CONTACT BLOCK 1 NC
+ XACA009 x 4 PADLOCK ATTACHMENT + XACA9411 x 4 ROUND HEAD FOR PUSHBUT TO N SPRING RETUR +
XACA9412 x 3 ROUND HEAD FOR PUSHBUT TO N SPRING RETUR + ZA2BS834 x 1 PUSHBUTTON

What is the max current rating of an ATS22 relay?

Issue:
What is the max current rating of an ATS22 relay?

Product Line:
Altistart 22, ATS22

Environment:
All

Cause:
N/A

Resolution:
Max switching capability:
5A - 250VAC or 30VDC on resistive load (p.f.=1)
2A - 250VAC or 30VDC on inductive load (p.f=0.4)

How many events does the onboard event log hold?

The event record will hold 30000 events before the log begins to FIFO the events.

What is the part number for a 6 gang switch for the Iconic range?

The part number for a 6 gang switch for the Iconic range is - 3046G & 3046C

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3046G
https://www.clipsal.com/Trade/search-results?q=3046C
User-added image

User-added image

 

Can a data or AV outlet be added on the plate with 800 series integrally switched sockets

No. The joint Australia/New Zealand Wiring Rules (AS/NZS 3000) require that all faceplates comply with AS/NZS 3112, clause 3.2 of which prohibits mixing of these voltage levels on the same faceplate

What is the minimum firmware needed for a PM710 or PM750 to upgrade to the latest firmware?

Product Line
PM700 Series

Environment
Firmware Upgrade

Resolution
The PM700 or PM7 series meters must be at firmware 3.040 or greater in order to upgrade to the latest firmware.

For information on how to upgrade to the latest version see FA237920.

Show More

Range

The Clipsal Iconic range is founded on a specialised electrically safe grid plate.
Once installed by an electrician, it’s safe for anyone to change the skins at any time by simply clipping off the standard skins and snapping on a new design.

Iconic’s interchangeable standard, Styl and Essence skins provide clever options tailored to suit a homes’ decor or family’s lifestyle.