Grid Socket Sw Horiz Twin 10A 250V

Clipsal Iconic - Twin Switch Socket Outlet Grid, Horizontal Mount, 250V, 10A

Catalogue Number: 3025G
Grid Socket Sw Horiz Twin 10A 250V
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switched socket
Device presentation
mechanism with fixing frame
Outlet poles configuration
2P + E with shutter
Device mounting
flush
Number of power socket outlets
2
Number of rocker
2
Range compatibility
cover frame
Outlet standard
Australian
Outlet standard description
with earthing contact
Outlet standard
Australian/New Zealand
Ground lug position
straight 180° position
Fixing mode
by screw
Installation direction
horizontal
Surface finish
matt
Type of packing
polybag
Quantity per set
set of 10
Sale per indivisible quantity
1
Rated current
10 A at 250 V AC 50 Hz
Electrical durability
12000 cycles
Connections - terminals
3 screw terminals
Screwdriver shape
  • square drive no 1 (SQ1)
  • Philips No 2
    • Clamping connection capacity
    • 1 x 2.5...4 x 2.5 mm² for rigid cable(s)
    • 1 x 2.5...4 x 2.5 mm² for stranded cable(s)
    • 1 x 2.5...4 x 2.5 mm² for flexible cable(s)
      • Wire stripping length
        16 mm
        Material
      • PC (polycarbonate): fixing frame
      • PP (polypropylene): rocker
      • POM (polyoxymethylene): shutter
        • Height
          71 mm
          Width
          115 mm
          Depth
          26 mm
          Embedding depth
          18 mm
          Net weight
          0.094 kg
          Ambient air temperature for operation
          0-45 °C
          Relative humidity
          10-95 %
          Standards
          AS/NZS 3112
          Product certifications
          RCM
          Sustainable offer status
          Green Premium product
          EU RoHS Directive
          Compliant
          Toxic heavy metal free
          Yes
          Mercury free
          Yes
          RoHS exemption information
          Yes
          China RoHS Regulation
           Pro-active China RoHS declaration (out of China RoHS legal scope)
          Environmental Disclosure
          ENVPEP120506EN
          Circularity Profile
          N/A

          Documents & downloads

          hide show
          Filter items
          • All

          • Product Brochures

          • Technical Data Catalogues

          • Technical Leaflet

          • Product Environmental

          • Installation Instruction

          • Operating Manuals

          • Certificates (MSDS)

          Frequently Asked Questions

          hide show

          What is screwdriver head size for Iconic 3025 GPO?

          The screwdriver head size for Iconic 3025 GPO is either size PH2 or SH1 can be used.

          Do the switches in Iconic switched socket outlet have LED indicators, example 3025?

          There are no LED indicators on the switches in Iconic switched socket outlet. The switches on the outlet have green markings so you know when it is switched ON.

          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3025



           

          What is the part number for the ICONIC night walk?

          The part number for the ICONIC night walk is a 3025NW. which is only the cover/sensor light. You will also need the grid which is a 3025G.

          Is grid only available for part number 4025?

          No. Unfortunately, Grid is not available for 4025.

          What is the mounting block for 4025?

          The part name is as follows: 449B-WE

          Is there an IP66 rated 2 gang vertical outlet in 2000 range?

          No there is no IP66 rated outlet in the 2000 series. For IP66 outlets the 56 Series would be the best option
          For Clipsal 2000 series information click this link https://www.clipsal.com/Trade/search-results?q=2025v

          For Clipsal 56 Series please click this link https://www.clipsal.com/Trade/search-results?q=56c310

          Is there a product data sheet for a 2025?

          Yes there is. Please see the attached PDF document.
          Some of the key features are:
          • 10A Rated
          • 250V Rated
          • Double Outlet
          • 2000 Series
          • Variety of colours
          For further information please visit Trade - Clipsal by Schneider Electric


           

          Is Grid plate only available for 4025?

          No its available as Grid & Cover.

          Is Saturn cover available for 4025?

          Yes. It is available and the part number is 4025C.

          What is the dimensions of part number 4025?

          Dimensions for part number 4025 are 116mm(W) 75mm (H) 15mm

          For further information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025

          Is the saturn single GPO (4015) available with extra switches?

          Not available. We have 4025XA - double GPO with extra removable switch  and 4025X - double GPO with extra non-removable switch

          What is the cover for a 4025X?

          The part number for the cover to suit the 4025X is a 4025C.

          Is there a red double horizontal socket available without the RCD, Neon, or Circ ID in the Medliec range?

          Yes, the 2025, double horizontal socket 250V 10A is available in red. Use the code 2025-RD.
           

          Do you have a double pole version of the 2025L?

          No, unfortunately we do not have a 2025L that is double pole.
          However we can offer the 25DL-WE which is a double pole double outlet with round earth pins.

          What is a 2000 Series power point?

          The 2000 Series power point is a 2025.
          • 10A Double Power Point
          • 240V AC
          • 2000 Series
          For further information please visit: https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025

          User-added image

          What is part number for cover to suit Saturn 4025?

          The part number for cover is 4025C.

          What is the part number for a wall box for the Saturn range double GPO , 4025?

          The part number for a wall box for the Saturn range double GPO , 4025 is - 157/1PRM

          For further information , visit link below:-
          https://www.clipsal.com/Trade/search-results?q=157/1PRM
          User-added image
           

          What is the part number of the cover to suit 2025?

          The part number is 2000-xx
          (xx is the color code)

          Please click this link for further information
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=2000

          User-added image

          Can you get the 4025X with a 35A mechanism?

          No unfortunately that particular switch only comes in 10A and is not removable.

          However, the 4025XA has a removable mechanism and can be replaced with the mechanism 60R32 which is a 32A mechanism.

          Some of the key features are:

          • Saturn Series
          • 10A
          • 250V
          • Extra removable switch
          • Various colours available

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025XA



           

          Do Saturn series power outlets have indicators on the switch mechanism?

          Saturn series power outlets (example 4025) do not have led indicators on the switch mechanism. Saturn series wall switches are available with the option of having blue LED indicators on the switch mechanism.
          For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000296.pdf
           

          What is the part number for a 6 gang switch for the Iconic range?

          The part number for a 6 gang switch for the Iconic range is - 3046G & 3046C

          For further information , visit link below:-
          https://www.clipsal.com/Trade/search-results?q=3046G
          https://www.clipsal.com/Trade/search-results?q=3046C
          User-added image

          User-added image

           

          What is the part number of the fixed Front Connection snap-in nuts for the Compact NS100 to 630 circuit-breakers.?

          The part number of a set of 12 fixed front connection snap-in nuts is:

          29234 for Compact NS100.
          30554 for Compact NS160... 250.

          These parts are not available for Compact NS400 to 630.

          What is the part number for a slimline double GPO with an extra , removable , switch mech?

          The part number for a slimline double GPO with an extra , removable , switch mech is - SC2025XA
          But because Slimline is no longer available Iconic 3025XA (PDL395X) is the next slimest option, or Classic C2025XA if you prefer the Slimline look.

          What are the part numbers to make up a 4 gang switch with LED for the Iconic range?

          The part numbers to make up a 4 gang switch with LED for the Iconic range are - 3044G , 40ML & 3044C

          For further information visit links below:-
          https://www.clipsal.com/Trade/search-results?q=3044G
          https://www.clipsal.com/Trade/search-results?q=40ML
          https://www.clipsal.com/Trade/search-results?q=3044C
          User-added image

          What is the part number for the grid only in the Iconic range double gpo ?

          The grid 3025VXUAG is suitable for both the 3025V and 3025VXA setup ( the 2 units share a common grid )

          Part number for Saturn cover for double outlet?

          The part number of a cover for a 4025 is 4025C.

          Some of the key features are:
          • Cover suit both 4025 and 4025X switched sockets
          • Double power outlet 

          For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=4025C

           

          What is the part number for Iconic foxtel TV outlet?

          The part numbers for Iconic Foxtel TV outlet are 3041G + 3041C-** + 40PFM-TN

          3041G Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang

          3041C-WY Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang

          Clipsal Iconic - TV Antenna Socket, 75 Ohm, F-Type

          For further information see:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G:https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-WYhttps://www.clipsal.com/Trade/search-results?q=40PFM
           

          What does 3F25 fault mean on a PV100-208 or 3F25\3F26 on a PV225-208?

          Issue:
          Unit faulted on 3F25 or 3F26

          Product Line:
          PV100-208 or PV225-208

          Environment:

          Cause:
          No LED on any of the three phases of the driver board

          Resolution:
          The power supply, PS1, provides 15VDC to the driver board. If the power supply is bad, no LED will be present. Check the power supply fuses F9 and F10 to see if they are blown or not. If blown, replace them and see if the fault can be cleared. If the replacement did not fix the issue or the fuses are blown again, call 866-519-1470 and select option 3 and 3 to open a case.
           

          M580 SD memory card format procedure

          M580 CPU SD memory card format procedure
          1. Connect to M580 and make sure the Unity project is “Equal”, “Run” and “Built”
          2. Stop the PLC
          3. Open SD card door and make sure LED is ON
          4. Open the “Animation Table” Window
          5. Add system word %SW93.0 and %SW93.1
          6. Turn on the “Modification” button
          7. Enter value “1” for %SW93.0
          8. (This will start the format of the SD card then that value will change back to “0” and the value of %SW93.1 will go from “0” to “1” to indicate the format has completed successfully), (Formatting a standard SD card takes about 30-50 seconds)
          9. When completed enter value of “0” for both %SW93.0 and %SW93.1
          10. Start PLC

          Is Iconic intermediate mechanism available assembled on a switch plate?

          Unfortunately, the Iconic intermediate mechanism is not available assembled on a plate. It can put together using below part numbers;
          40MIL  - Clipsal Iconic Intermediate Switch Mechanism, 250V, 10A, LED.
          +
          3041G - Clipsal Iconic - Switch-Grid, Vertical/Horizontal Mount, 1 Gang
          +
          3041C - Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang
          For further information, please visit the below links:
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=40MIL
          https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G
          https://www.clipsal.com/Trade/search-results?q=3041C


          What part numbers are needed to put together an Iconic 1 gang electronic Pushbutton switch plate (Vivid white)?

          Below are the part numbers needed to put together an Iconic 1 gang electronic Pushbutton switch plate :

          3041G - Clipsal Iconic - Switch Grid, Vertical/Horizontal Mount, 1 Gang
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041G

          +

          3041C-VW -Clipsal Iconic - Skin Switch Plate Cover, Vertical/Horizontal Mount, 1 Gang, Vivid White
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=3041C-VW​

          +
          41E350PBES2SM-VW -Clipsal Iconic - Electronic Switch Mechanism, Push Button with ControlLink (without bluetooth) 2-wire, 350W
          For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=41E350PBES2SM

          How is MTBF (Mean Time Between Failures) Calculated?

          Goals and Symptoms:

          How is MTBF (Mean Time Between Failures) Calculated?

          Causes and Fixes:

          How is MTBF (Mean Time Between Failures) Calculated?

          1. Computed following RDF2000 Reliability model (UTE C 80-810 standard) - EQUIPMENT ambient temperature at 30deg C (86deg F), 60deg C (140deg F) and 85deg C (185deg F)
          • 2. Continuous operation profile: 100% operation rate per year (365d / year, 24h / day) - 12 power on/off per year (1 per month) - No stocking days
          • 3. Intermittent operation profile: 46% operation rate per year (335d / year 12h /day) - 335 power on/off per year (1 per operating day) 30 stocking days
          • 4. MTBF are given in hours

          How to determine the Date of Manufacture for a PM800 Series Meters

          Issue:
          A user may need to determine the manufacture date of a PM800 series meter

          Product Line:
          PM800 series meters

          Environment:
          Manufacturing Information

          Cause:
          The date of manufacture is required by the RMA procedure

          Resolution:
          *Warning: Installation and maintenance of this device should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current devices. Failure to follow the instructions / warnings in the Meter Installation Guide can result in permanent damage to the meter, severe injury or death. 

          There are three ways to determine the Date Of Manufacture (DOM) of a PM800 series meter.

          1. Front Display
          From the front display of the meter, Select "Diagnostic -> Meter Information -> DOM"
          You can read the "DOM" registers from the meter:

          2. Register Reads
          Three registers in the meter contain the DOM information starting at 3019. You can use Modbus tester or any Modbus register reading tool to read three registers (3019, 3020, and 3021). To download Modbus Tester, click on article FA180037

          Please use the following template for interpretation:
           
          Register 3019:Hi Byte = Month (1 - 12) ; Register 0:Lo Byte = Day (1 - 31)
          Register 3020 :Hi Byte = Year (0 - 199)   ; Register 1:Lo Byte = Hour (0 - 23)
          Register 3021 :Hi Byte = Minute (0 - 59) ; Register 2:Lo Byte = Second (0 - 59)

          3. Product Information Label
          Caution: Take all necessary precautions when exposing live energized circuits
           