Compact Interpact Switch Disconnector INS100, 3 Poles, 100A

Compact Interpact Switch Disconnector INS100, 3 Poles, 100A

Compact Interpact Switch Disconnector INS100, 3 Poles, 100A

Item Number: 28908

Retail
$570.79
RRP (Inc. GST)

Product Dimensions

Width icon

Width135 mm

Height icon

Height100 mm

Depth icon

Depth62.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Compact

Range of product

INS40...160

Product or component type

switch disconnector

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[Ie] rated operational current

  • AC-22A: 100 A AC 50/60 Hz 220/240 V
  • AC-23A: 63 A AC 50/60 Hz 660/690 V
  • DC-22A: 100 A DC 125 V 2 poles in series
  • DC-23A: 100 A DC 125 V 2 poles in series
  • AC-22A: 100 A AC 50/60 Hz 380/415 V
  • AC-22A: 100 A AC 50/60 Hz 440/480 V
  • AC-22A: 100 A AC 50/60 Hz 500 V
  • AC-22A: 100 A AC 50/60 Hz 660/690 V
  • AC-23A: 100 A AC 50/60 Hz 220/240 V
  • AC-23A: 100 A AC 50/60 Hz 380/415 V
  • AC-23A: 100 A AC 50/60 Hz 440/480 V
  • AC-23A: 100 A AC 50/60 Hz 500 V
    • [Ue] rated operational voltage

    • 125 V DC
    • 690 V AC 50/60 Hz
      • Control type

        rotary handle

        Mounting mode

        fixed

        Mounting support

      • plate
      • DIN rail
        • Mechanical durability

          15000 cycles

          Electrical durability

        • AC-22A: 1500 cycles 220/240 V AC 50/60 Hz
        • DC-23A: 1500 cycles 250 V DC 2 poles in series
        • AC-22A: 1500 cycles 690 V AC 50/60 Hz
        • AC-23A: 1500 cycles 690 V AC 50/60 Hz
        • AC-22A: 1500 cycles 380/415 V AC 50/60 Hz
        • AC-22A: 1500 cycles 440 V AC 50/60 Hz
        • AC-22A: 1500 cycles 500 V AC 50/60 Hz
        • AC-23A: 1500 cycles 220/240 V AC 50/60 Hz
        • AC-23A: 1500 cycles 380/415 V AC 50/60 Hz
        • AC-23A: 1500 cycles 440 V AC 50/60 Hz
        • AC-23A: 1500 cycles 500 V AC 50/60 Hz
        • DC-22A: 1500 cycles 250 V DC 2 poles in series
          • Height

            100 mm

            Width

            135 mm

            Depth

            62.5 mm

            Net weight

            0.8 kg

            Standards

          • IEC 60947-3
          • IEC 60947-1
            • Product certifications

            • CCC
            • KEMA-KEUR
              • IP degree of protection

                IP40 conforming to IEC 60529

                IK degree of protection

                IK07 conforming to EN 50102

                Ambient air temperature for operation

                -25-70 °C

                Ambient air temperature for storage

                -50-85 °C

                REACh free of SVHC

                Yes

                EU RoHS Directive

                Compliant

                Toxic heavy metal free

                Yes

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                X

                Environmental Disclosure

                ENVPEP1304024

                California proposition 65

                WARNING: This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov

                Others

                Product name

                Compact INS

                Device short name

                Compact INS100

                Switch-disconnector name

                Compact INS100

                Poles description

                3P

                Network type

              • AC
              • DC
                • Network frequency

                  50/60 Hz

                  [Ui] rated insulation voltage

                  750 V AC 50/60 Hz

                  [Uimp] rated impulse withstand voltage

                  8 kV

                  [Ith] conventional free air thermal current

                  100 A at 60 °C

                  [Icm] rated short-circuit making capacity

                • 154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
                • 20 kA switch-disconnector alone 690 V AC at 50/60 Hz
                  • Suitability for isolation

                    yes

                    Contact position indicator

                    yes

                    Visible break

                    no

                    Pollution degree

                    3

                    Handle colour

                    black

                    Upside connection

                    front

                    Downside connection

                    front

                    Maximum power

                  • AC-23: 22 kW at 220/240 V AC 50/60 Hz
                  • AC-23: 45 kW at 380/415 V AC 50/60 Hz
                  • AC-23: 55 kW at 440 V AC 50/60 Hz
                  • AC-23: 55 kW at 500/525 V AC 50/60 Hz
                  • AC-23: 55 kW at 660/690 V AC 50/60 Hz
                    • Rated duty

                      uninterrupted

                      Intermittent duty class

                      class 120 - 60 %

                      Enclosure dimensions for Ithe

                      260 mm x 160 mm x 55 mm

                      [Icw] rated short-time withstand current

                    • 0.01 kA during 30 s conforming to IEC 60947-3
                    • 1.23 kA during 20 s conforming to IEC 60947-3
                    • 3.175 kA during 3 s conforming to IEC 60947-3
                    • 5.5 kA during 1 s conforming to IEC 60947-3
                      • Connection pitch

                        30 mm

                        Compatibility code

                        INS100

                        Unit Type of Package 1

                        PCE

                        Number of Units in Package 1

                        1

                        Package 1 Weight

                        1.048 kg

                        Package 1 Height

                        11.7 cm

                        Package 1 width

                        13.3 cm

                        Package 1 Length

                        15 cm

                        WEEE

                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                        Show all specifications

                        Documents & downloads

                        hide show

                        Frequently Asked Questions

                        hide show

                        What is the load break switch 63Amp 3P dinrail mounted with extended rotary handle

                        You can use a 28902 load break switch with a LV428941 extended rotary handle

                        What is the part number for long terminal shields to suit the INS100

                        The long terminal shields are the 28958 which is a set of 2.

                        Is there a replacement handle for the INS63 / 28902?

                        Yes - The 28962 suits the INS40 - INS60 load break switches

                        What is the replacement for RM4JA01F?

                        The replacement is RM22JA21MR, but if not in stock, can offer the RM35JA31MW 
                        see data sheets for more information.....https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RM35JA31MW
                        https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RM22JA21MR
                        User-added image

                        What is the replacement for the RM4JA32F?

                        Replacement for the RM4JA32F is the RM35JA32MW
                        For more information, see data sheet.....https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=RM35JA32MW
                        User-added image

                        Does a UV trip or UVR undervoltage release sense phase loss?

                        Issue:
                        Does a UV trip or UVR undervoltage release sense phase loss?

                        Product Line:
                        Circuit Breakers

                        Environment:
                        Circuit breakers that have a UVR undervoltage trip

                        Resolution:
                        The UVR will sense phase loss only on the phase from which its power is taken. The UVR should not be used for a phase failure application, as it can only monitor one phase.
                        Show More