end cap conduit 100mm p/pipe

Solid Fittings - PVC, Conduit Caps, 100mm - Suits 100mm pressure pipe

Catalogue Number: 262P100
end cap conduit 100mm p/pipe
Retail
$107.21
RRP (Inc. GST)
Colour Electric Orange (EO)
  • Electric Orange 1 PCE

Specifications

hide show
Product brand
Clipsal
Range of product
Series 262
Material
PVC (polyvinyl chloride)
Diameter
  • inner: 114.5 mm
  • outside: 122 mm
    • Length
      48 mm
      Unit Type of Package 1
      PCE
      Number of Units in Package 1
      1
      Package 1 Weight
      120 g
      Package 1 Height
      48 mm
      Package 1 width
      122 mm
      Package 1 Length
      122 mm
      Sustainable offer status
      Green Premium product
      REACh free of SVHC
      Yes
      EU RoHS Directive
      Pro-active compliance (Product out of EU RoHS legal scope)
      Toxic heavy metal free
      Yes
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
       Pro-active China RoHS declaration (out of China RoHS legal scope)
      Environmental Disclosure
      ENVPEP100802EN

      Frequently Asked Questions

      hide show

      Are there Certificates of Conformity for the 247P100 and 262P100?

      No. Unfortunately, there are not.

      What is the radius of part no 247PH100

      Bend Radius for 247PH100 is 715mm

      What material is the XVBC02 & XVBC11 made of?

      Issue:
      What material is the XVBC02 & XVBC11 made of?

      Product Line:
      Harmony Pushbuttons

      Environment:
      All Products

      Cause:
      Product Features

      Resolution:
      The XVBC02 is stainless steel (matte black finish). The XVBC11 tulip is a Zinc alloy (black matte finish).


      CTA-ID : 2023180

      ACRP100 Installation Manual

      Issue:  
      This article contains the full ACRP100 Installation Manual.

      Product line:
      ACRP100, ACRP101, ACRP102.

      Environment:  
      All Serial Numbers.    
       
      Cause:   
      Installation Manual.

      Resolution:   
      See File below

      Spurious triggers of transient module on ION 7550/7650 and ION8800

      Issue
      ION 7650/7550 and ION 8800 series devices can cause spurious triggering of the transient module when transients do not exist. This issue exists in firmware up to and including V354 for the ION 7650 and V334 for the ION 8800.

      Symptoms
      ION meters displaying this issue will find the transient module on ION 7650 and ION 8800 devices will trigger intermittently or with a fairly regular pattern (i.e. about every 15 minutes) while no corresponding real observable transient event actually occur in the monitored electrical system. The following observations may be describing this issue:

      1. Too many transients events being triggered. Unduly frequent transient events being recorded with associated waveform captures.
      2. Inspection of the waveform captures from transient events show no changes of the waveform.
      3. Transient module triggering regularly with no real corresponding power quality events in the actual physical electrical system being monitored.
      4. Adjustment of the transient module's threshold value doesn't seem to make much difference to the rate of transient triggers.
      5. Re-programming of the meter framework (by pasting the framework from a healthy meter, for example) does not fix the problem.
      6. Newer meters such as the ION 7650 and ION8800 show this problem while older ION meters (ION7600 and ION 8500) with the same or similar framework seem to be immune.​
      Product Lines
      ION7650
      ION8800

      Environment
      Transient Module

      Cause
      The issue is observed when a large nominal voltage (approximately 131,000) is linked to the transient module. The nominal voltage is multiplied internally by the maximum A/D count value, and with the large nominal voltage this calculation overflows a 32-bit integer. The problem will be most noticeable when the nominal voltage is slightly larger than the roll -over value - in this case, the roll-over will result in a very small transient threshold value, and therefore a large number of transients detected. E.g. nominal voltages of 131,000 or 262,000 will be most noticeable, while a nominal voltage of 250,000 would not be as noticeable."

       

      Resolution
      Update the firmware to V355 or newer for the ION 7650 and V340 or newer for the ION 8800.

      If a firmware upgrade is not possible or spurious triggers still persist, scale down the nominal voltage input to the transient module, and increase the threshold setting by a proportionate amount.
      E.g. If the nominal voltage was 140,000, and the threshold was 25%, make the nominal voltage 70,000 and the threshold 50%. This would detect transients with the same sensitivity as the original settings, but the reported values would be different (i.e. the reported magnitude would be twice as large, and the reported nominal would be half of what it should be). The framework would also have to be modified so that a custom value was linked into the transient nominal - otherwise changing this setting would affect other operations on the meter such as sag/swell detection.

      *This issues only affects PRODUCTS with transient capability. This issue affects other product lines with transient capabilities (ie. ION 8500, ION 7600) although only for voltages above 1MV so in practicality it should not appear.

      What is the VA rating of a 9001KM 120V LED light module?

      Issue:
      What is the VA rating of a 9001KM 120V LED light module?

      Product Line:
      Push Buttons and Operator Interface

      Environment:
      30mm, 9001KM, 9001K, 9001SK

      Resolution:
      All 9001KM 120V LED:  9001KM38LR, 9001KM38LG, 9001KM38LY, 9001KM38LW, 9001KM38LL have a  1.4VA rating.

      What is the replacement operating handle for VCD__ Vario door mounted manual motor control switch?

      Issue:
      What is the replacement operating handle for VCD__  Vario door mounted manual motor control switch?

      Product Line:
      VCD02 VCD01 VCD0 VCD1 VCD2

      Environment:
      All

      Cause:
      Repair part

      Resolution:
      The operating handle is KCD1PZ.  It is a red handle with 60mm x 60mm yellow legend plate for single hole mounting. Note that the operating handle will accept up to three padlocks.

      What is the difference between an XVBC02 & XVBZ02?

      Issue:
      What is the  difference between an XVBC02 & XVBZ02?

      Product Line:
      Harmony Signalling

      Environment:
      All products

      Cause:
      Product Features

      Resolution:
      The XVBC02 is a 3.94``h stainless steel (black matte finish) support tube. The XVBZ02 is an aluminum (black matte finish)tube with a tulip base ( all one piece) and replaces this stainless item . Another newer option is an XVBZ02A tube and tulip base which is silver aluminum .

       

      Are the ZB2 and ZB4 operators interchangeable ?

      Issue:
      Are the ZB2 and ZB4 operators interchangeable?
      Product Line:
      22mm push button operators
      Environment:
      ZB4/ ZB5 22mm operators, ZB2 22mm operators
      Cause:
      Determine if the existing ZB2 unit has to be completely replaced, or replacement parts are available.
      Resolution:
      No, the ZB2 operators can’t be used with the ZB4 contacts and light modules and the ZB4 operators cannot be used with the ZB2 contacts and light modules. The lines are both 22mm so the complete devices can be substituted.
       

      Where are the EDS files for the ATV58 Devicenet communication card?

      Issue:
      Where are the EDS files for the ATV58 Devicenet option card.

      Product Line:
      Altivar ATV58 with Devicenet option card

      Environment:
      Product versions 5.X and 3.X only

      Cause:
      EDS files for the Devicenet option card for the ATV58 drives.

      Resolution:
      You will need to find the product version of the drive before you install your EDS file.   Remove the keypad from the VFD and you will see a white sticker with a product version on it.
      I have attached ATV58 EDS files for product version 3.X and 5.X

      CTA-ID : 2027180

      Why does an ATS48 soft starter with remote keypad will only allow access to status and SUP menu?

      Issue:
      Why does an ATS48 soft starter with remote keypad will only allow access to status and SUP menu?

      Product Line:
      ATS48 Soft starter with remote HMI

      Environment:
      All

      Cause:
      keypad is locked or stuck on SUP menu

      Resolution:
      On the back of the remote keypad, there is a 3 position switch.  If this switch is in the ``FULLY LOCKED`` position, it will not allow access to any menus other than SUP.  Move this switch to the ``FULLY UNLOCKED`` position to gain access to all menus within the starter.

      What is the advantage of the Protected LED light modules in the new XB4 and XB5 22mm push button lines?

      Issue:
      What are the characteristics of our XB4/XB5 light module?

      Product Line:
      Harmony Push Buttons

      Environment:
      North American Products

      Resolution:
      The light module contains electronics to handle surges on the control system.
      Specific characteristics and ratings of Protected LED light modules:

      Surge withstand Conforming to IEC 61000-4-5 2/1 kV,
      Resistance to fast transients Conforming to IEC 61000-4-4 2 kV
      Resistance to electromagnetic fields, Conforming to IEC 61000-4-3 10 V/m
      Resistance to electrostatic discharges, Specific Characteristics of Protected LED Light Modules Only

      Voltage limits
      Nominal voltage
      24 V: 19.2 to 30 Vdc; 21.6 to 24.6 Vac
      120 V: 102 to 132 Vac
      240 V: 195 to 264 Vac

      Current consumption Applicable to all colors
      24 Vac/Vdc supply blocks: 18 mA
      120 Vac supply blocks: 14 mA
      240 Vac supply blocks: 14 mA

      Service life At nominal voltage and at an ambient temperature of 77 F (25C)
      100,000 hours

      Resistance to electrostatic discharges, Conforming to IEC 61000-4-2 8/6 kV,
      Electromagnetic emission Conforming to EN 55011 Class B
      Conforming to IEC 61000-4-2 8/6 kV


       
      Show More