box junction clip adaptor

Clip Adaptor, Suit Round Junction Box

Catalogue Number: 240CA
box junction clip adaptor
Colour: Transparent
Colour: Per UOM Std.
  • Transparent 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 240CA
Product brand
Clipsal
Product or component type
clip adaptor
REACh free of SVHC
Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What size hole saw is required for the 240CA ?

As  per installation instructions use a 63mm hole saw to cut holes.

Is it possible to monitor loads above 2400A with the Enercept Meter?

Veris Industries manufactures Multi-turn coils which make this application possible. Reference the below document which describes the process when using the Multi-turn coils.
vn19_CoilLoopsFor2400+Loads.pdf


Legacy KB System (APS) Data: RESL205867 V1.0, Originally authored by MaTh on 07/27/2011, Last Edited by MaTh on 07/27/2011
Related ranges: Enercept

What is the coil consumption or burden for the Tesys LC*D** contactors?

Issue:
What is the coil consumption or burden for the Tesys LC*D** contactors?

Product Line:
Tesys Contactors and Overload Relays

Environment:
All Products

Cause:
Product Features

Resolution:
All AC coils for the LC1D40 through LC1D80 3 or 4-pole contactors have an inrush of 200VA for 50 Hertz applications or 220VA for 60Hz.
Sealed values are 20VA for 50 Hertz applications or 22VA for 60 Hertz applications. For 50/60 Hertz coil inrush is 245VA and sealed is 26VA


CTA-ID : 2029994

Are 2400va high powered dimmers still available?

No. Unfortunately, we no longer have the high power dimmer available.

Is the 230CS board still available?

 No, unfortunately the 230CS is no longer available.

For further information please visit https://www.clipsal.com/Trade

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

240L, does it come with screws?

Yes,

SCREW SS 3/16BSWX8.5 CB/CH HD

What is the spare coil for LC1D32 240V?

  LXD1U7

3090SCCT Frequently Asked Questions

Product Line
3090SCCT

Environment
Current Transformer

Resolution
What is the minimum load require for accurate readings?
A load of 10% of the max load is required in order to saturate the CT.

For example, a 3090SCCT124 with a 1200A maximum requires a 120A load to be accurate.

Note:Technical support will not troubleshoot loads below 10%.

Is there a 3090SCCT smaller than 200:5?
No. If more accuracy is required please see FA212449 for Solid Core CTs.

Which wire is the positive and negative for the 3090SCCT?
X1, S1, or H1 is the positive wire.
X2, S2, or H2 is the negative wire.

Schneider Electric model SCCT current transformers identify the X1 wire as WHITE and the X2 wire as BLACK.


See FA212245 for all of the wiring standards of the 3090SCCT.

Where can the 3090SCCT cut sheet be found?
The cut sheet for 3090SCCT can be found in FA212730.

Can the leads be extend on the 3090SCCT?
Yes. Please see FA212841.

Are 3090SCCTs sold individually or in sets?
Individually. 

Are the 3090SCCT series current transformers rated for outdoor use?
No. Please see FA212946.

What is the part number for the 3090SCCT?
Part Number Description
3090SCCT022 SPLIT-CORE CT, 200A, 1.25" X 1.51" ID
3090SCCT032 SPLIT-CORE CT, 300A, 1.25" X 1.51" ID
3090SCCT043 SPLIT-CORE CT, 400A, 2.45" X 2.89" ID
3090SCCT063 SPLIT-CORE CT, 600A, 2.45" X 2.89" ID
3090SCCT083 SPLIT-CORE CT, 800A, 2.45" X 2.89"ID
3090SCCT084 SPLIT-CORE CT, 800A, 2.45" X 5.50" ID
3090SCCT124 SPLIT-CORE CT, 1200A, 2.45" X 5.50" ID
3090SCCT164 SPLIT-CORE CT, 1600A, 2.45" X 5.50" ID
3090SCCT204 SPLIT-CORE CT, 2000A, 2.45" X 5.50" ID
3090SCCT244 SPLIT-CORE CT, 2400A, 2.45"X5.50" ID

Notes:
  1. For split-core CTs rated for 2400A to 6000A, please refer to FA359622
  2. For quotes, please contact inside sales at 615-538-3845.

What colours are the PDL 680M32 available in?

The PDL 680M32 (switch module, 1 way, 2 terminal, 32A, 240V) is only available in white or black.
https://www.pdl.co.nz/product-details.aspx?rcat=products&catid=0&id=825

What is the alternative for the 250ml clear glue 240A?

There is no direct alternative to the clear 250ml jointing cement in the squeeze bottle.

We only offer our range of four sizes with a brush incorporated in the lid.    

For further information please visit https://www.clipsal.com/Trade/search-results?q=jointing%20cement.

What is the replacement for a Merlin Gerin 26860, RCBO, 240V, 20A, 30mA?

The replacement for a Merlin Gerin 26860, RCBO, 240V, 20A, 30mA is a A9D11820.

Is there an operation in Unity Pro that replaces the Concept M1HEALTH function block?

No.
The Concept M1Health function block was used to monitor local IO and distributed IO Bus slaves.
All of the same functionality can be reproduced in Unity Momentum with System Words.
Local IO Base can be monitored using %SW119. 
IO Bus Health can be monitored using %SW118. 
Slave Module Health can be monitored using %SW128, %SW129.

Does there need to be any segregation between DALI and 240V?

No – The DALI line must be run in a cable that is mains rated (i.e. minimum 1.5mm mains rated twin cable or 5-core soft cabling). As a rule of thumb, you should presume the DALI Line cable has mains voltages present and therefore you should treat the cable type requirements accordingly.

Do you have a smoke alarm that doesn't connect to 240V?

All our smoke alarms need to be hard wired with a 240V supply.
However, they have battery backup in case of power failure.

For further information please visit https://www.clipsal.com/Trade/search-results?q=smoke%20alarm

I am looking for a wall fan with a 240mm cutout and is physically approx 300mm square

You can use a Clipsal 7106A or 7108A both have a 230mm cut out and are 271mm square

What is the Cut out Size of the clipsal CE200 Fan Assembly ?

The cut out Size is 240mm Diameter cut out.
 

Can Power Supply ABL7RM 24025 be din rail mounted?

Yes, ABL7RM24025 can be din rail mounted, it also has 2 x 4mm panel mount holes.

 

What is part number for Red Neon 240v mech?

Unfortunately, we have part number 30N-RD which is 250v mech but nothing available in 240v.

Is the 15216 DC rated

The primary voltage 240VAC

Is there a LHC882 C-Bus Modena switch available in standard 240V?

Yes there is a standard 240V Switch that looks the same as a LHC882 C-Bus Modena switch.
The part number is M8082LHA.
Some of the key features are:

  • Blue LED indicator
  • Horizontal plate
  • Front loading rocker switches
  • 84 mm mounting centre

For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=M8082LHA

 

 

TSXSCP114 and TSXSCP1114 serial communications baud rate ranges

 

Goals and Symptoms

This Resolution clarifies the baud rate ranges for the TSXSCP114 and TSXSCP1114 RS422/RS485 Serial Communication cards.

 
Facts and Changes

Unity allows the user to select the same baud rate ranges between the TSXSCP114 and TSXSCP1114 even though their baud rate ranges are different.  Unity does not limit the selection of the baud rates based on the communication card configured.
 

Causes and Fixes

 The baud rate ranges are as follows:

    TSXSCP114 - 1200, 2400, 4800, 9600, 19200

    TSXSCP1114 - 1200, 2400, 4800, 9600, 19200, 38400, 57600

The default baud rate is 9600.

Additional Information

Reference Premium and Atrium using Unity Pro Asynchronous Serial Link User Manual, 10/2013.  Part number, 35006178.12.

What are the dimensions for 5600ICP speaker?

The dimensions for the 5600ICP speaker is 240mm X 90MM with a speaker diameter of 6 inches.

For further information please visit https://www.clipsal.com/Trade/Products/Product
 

What is the part code 3P 65Amp 240Vac coil  AC-3 contactor

The part code LC1D65AU7 

240VAC spare coil for LC1D18U7 Contactor?


Code = Lxd1u7

What is the part number for a Square D 240VAC 32amp RCBO?

The part number for a Square D 32 amp 240VAC RCBO is- QO132B10RCBO30F

For further information , visit link below:-

https://www.schneider-electric.com.au/en/search/QO132B10RCBO30F

What is the part number for a 3 pole 150amp contactor with 240VAC coil?

The part number for a 3 pole 150amp contactor with 240VAC coil is - LC1D150U7

For further information , visit link below:-
https://www.schneider-electric.com/en/search/LC1D150U7

What is the part number for a 4 pole 40amp 2 N/C 2 N/O 240VAC coil contactor?

The part number for a 4 pole 40amp 2 N/C 2 N/O 240VAC coil contactor is - LC1D258U7

 

What is the part number for a 240VAC single phase DOL starter ?

Customer would have to use 3 phase starter with 240VAC coil and just use 1 or 2  of the contacts on the contactor.

What is the part number for a 25amp contactor 3 pole 240VAC coil?

The part number for a 25amp contactor 3 pole 240VAC coil is - LC1D12U7

For further information visit link below:-
https://www.schneider-electric.com.au/en/search/LC1D12U7
User-added image

What is the part number for a 240VAC buzzer?

The part number for a 240VAC buzzer is - XB5KSM
For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/XB5KSM
User-added image

What is the part number for a transformer - 240VAC to 24VDC?

The part number for a transformer - 240VAC to 24VDC is - ABL8RPS24100

For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/ABL8RPS24100
User-added image

What is the part number for a 1 pole, 25A, 240V, D curve, 10KA Clipsal circuit breaker?

4CB125D10 is the part number for a 1 pole, 25A, 240V, D curve, 10KA Clipsal circuit breaker. Dimensions are as follows:

For further information please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=4CB125D10
User-added image
 

Can TM2 expansion output module be used for 240VAC PS Twido controller?

The answer is yes. The expansion output module (relay or transistor) attached to the controller is powered by the base controller. For a 240VAC supplied base controller, there is an embedded power converter inside to convert the 240VAC to 24VDC for supplying the microprocessor and of course the expansion modules.  So there is no 240VAC version of expansion output module exist, all the modules can be used for both controllers powered by 240VAC or 24VDC.  
 

What changes need to be made to accommodate 240 volts on the input to the Matrix-UPS?


The input voltage selector must be adjusted in order to accommodate the new voltage requirement. This process is outlined on page 10 of the owner's manual.

Is there a vertical 500 series Shaver socket

PDL 2014 Pocket book - page 73, PDL1575
Universal 110V and 240V, direct replacement for the 63T
Note:Plate dimensions 146 x 90mm (HxW).
Mounting Centres 120mm (Flush box is PDL31) 

What are the dimensions of the ceiling speaker 5600ICP?

The dimensions of the ceiling speaker 5600ICP are as follows:
Box Dimensions : 240mm diameter
Speaker : 6” diameter
Weight : 1.5Kg
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=5600ICP
User-added image
 

FCL Current Transformers

Issue
Customer needs split-core CT with an amperage rating greater than 2400 A

Product Line
Model FCL Current Transformers

Environment
Current Transformers

Resolution
Model FCL Current Transformers have current ratios from 200/5 to 6000/5 A. They are a split-core type current transformer.

Please find cutsheet for Model FCL Current Transformers attached. 

 For quotes for FCL CTs please contact sales.

Does the L5504RVF have it's own power supply?

Yes it has a 200mA power supply..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=L5504RVF
User-added image
 

What is the part number for a DOL starter with overload rated 5.5 - 8 amps and 240VAC coil?

The part number for a DOL starter with overload rated 5.5-8amp and 240VAC coil is - LE1M35U714
For further information , please visit link below:-
https://www.schneider-electric.com.au/en/search/LE1M35U714

What is the part number for a 1 pole 25amp contactor with 240VAC coil, din rail mount?

The part number for a din rail mounted 25amp , 1 pole , 240VAC coil contactor is - A9C20731
For furthe information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9C20731
 

What is the part number for a 40amp contactor , din mount , 4N/C contacts and 240VAC coil?

The part number for a 40amp contactor , din mount , 4N/C contacts and 240VAC coil is rated  AC7a  - A9C20847

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9C20847

What is the part number for a 4 pole N/C 25amp contactor 240vac Contactor for Emergency lighting control?

Part number for a 4 pole N/C 25 amp contactor 240vac Contactor for EM lighting control is a A9C20837
See data sheet for more information.....https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9C20837
User-added image

What is the part number for a 4 pole 25amp contactor with 4 N/O contacts and 240VAC coil?

The part number for a 4 pole 25amp contactor with 4 N/O contacts and 240VAC coil is - LC1DT25U7

For further information , visit link below:-
https://www.schneider-electric.com/en/search/LC1DT25U7

What is the part number for a 3 pole 1000V contactor for 225amps and 240VAC coil?

The part number for a 3 pole 1000V contactor for 225amps and 240VAC coil is - LC1F225U7

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/LC1F225U7

What is the part number for a 3 pole 40amp contactor with a 240VAC coil?

The part number for a 3 pole 40amp contactor with a 240VAC coil is - LC1D40AU7.

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/LC1D40AU7

What is the part number for a 56 series socket outlet , 240VAC 10amps?

The part number for a 56 series socket outlet , 240VAC 10amps is - 56SO310

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56SO310
User-added image
 

What is the part number for a 3 pole 115amp contactor with 240VAC coil?

The part number for a 3 pole 115amp contactor with 240VAC coil is - LC1D1156U7

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/LC1D1156
User-added image

What is the part number for a 4 pole 32amp contactor with 240VAC coil?

The part number for a 4 pole 32amp contactor with 240VAC coil is - LC1DT32U7

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/LC1DT32U7
User-added image

What is the part number for a 4 pole N/O 25amp 240VAC coil , din mount contactor?

The part number for a 4 pole N/O 25amp 240VAC coil , din mount contactor is - A9C20834

For further information , visit link below:-
https://www.schneider-electric.com.au/en/search/A9C20834
User-added image
Show More