Mounting box 25mm entries
box mounting pvc rect 2 ent
Mounting box 25mm entries
Mounting box 25mm entries
box mounting pvc rect 2 ent
Mounting box 25mm entries

Surface Enclosures, Mounting Box With 20 mm End Entries

Catalogue Number: 238
Mounting box 25mm entries
box mounting pvc rect 2 ent
Mounting box 25mm entries
Mounting box 25mm entries
box mounting pvc rect 2 ent
Mounting box 25mm entries
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Grey 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Number of gangs
1 gang
Shape
rectangular
Device mounting
surface
Cable entry number
2
Material
plastic
Length
115 mm
Depth
38 mm
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Do you do a 238 mounting block with a 50mm entry?

No, unfortunately the 238/25 has the largest conduit entry with a 25mm entry at each end.

For further information please visit https://www.clipsal.com/Trade/search-results?q=238/25

Does Clipsal do a 238 with 25mm entries, top and bottom?

No we don't. The closest we get is the 238A/25 with one 25 entry on the top.

What is the part number for a 238 in black?

The part number for a 238 in black is 238-BK.

Some of the key features are:
  • 1 gang
  • 84 mm mounting center
  • Horizontal and vertical mounting direction
  • 2 way
  • Suitable for 1 outlet
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=238




 

Do you have a 32A version of a 438 extension socket?

No, the largest rated version of a 438 extension socket is the 438/20 which is 20A.

What is the part number for 238A with 25mm spout?

The 238/25 has 1 x 25 mm spout & 2 x25 mm conduit entries.

Is there an insulated version of 450VC vertical corrugated iron mounting block?

Unfortunately, we do not have an insulated version of 450VC. Depending on the requirement we have 238 mounting boxes or the black plastic insulating shroud which can be used with 450VC. Customer needs to ensure they are following the wiring regulation. 

For further information, please visit 
https://www.clipsal.com/Trade/Products/ProductDetail?catno=238 
https://www.clipsal.com/Trade/search-results?q=insulating%20shroud


238

What is the part number of a 23A -32A overload to fit LC1D40U7 contactor?

LRD3353 is a 23A -32A overload to fit LC1D40U7 contactor. 
For further information, please visit https://www.schneider-electric.com/en/product/LRD3353/tesys-lrd-thermal-overload-relays---23...32-a---class-10a



 

How to configure the SER2408/3200 device to work with the Generator Performance module in PME.

Issue
When attempting to assign I/O in the generator performance module, one is unable to locate all input assignments.

Product Line
Power Monitoring Expert 8.x
Data center Edition
Health Care Edition

Environment
Generator Performance module 
Data center

Cause


Resolution
Before the device can be properly configured in the Generator Performance Configuration Tool it must first be configured and added into PME properly.
After device data is logged into the database, you can assign device measurements using the Generator Performance Configuration Tool with EPSS Test Module.

Please refer to page 238 of t he Applications modules configuration guide for instructions on configuring the SER hardware.
 

Part numbers for replacement phoenix contact connectors for common ION and Powerlogic meters and gateways.

Issue
A user would like a replacement terminal connector for an ION or Powerlogic meter or gateway

Product Line
ION6200 Series meters
ION7300 Series meters
ION7500/7600/7550/7650 Series meters
PM5000 Series meters
PM8000 Series meters
EGX100/300 Gateways

Environment
Power Monitoring
Energy Management


Cause
Replacement parts needed for Phoenix contacts.

Resolution
Schneider Electric does not sell the connectors. A distributor who sells PhoenixContact connectors is required. The parts are referred to as terminal block plugs. Common connectors and the PhoenixContact part number are shown below.
 
ION6200 Connectors

Phoenix Contact part #

Control Power 1900785
 
ION7300 Connectors

Phoenix Contact part #

Control Power 1767012
Analog Input 4 x 1803578
Analog Output 1803604
Digital Output 1803617
Communications 1803617
 
ION7330 & ION7350
ION 7550

Phoenix Contact part #

Control Power 1767012
Digital Input 1803604
Digital Output 1803617
Communications 1803617
 
ION7550 & ION7650
Connectors

Phoenix Contact part #

Control Power 1767012
Digital Input 1900840
Digital Output 1900837
Analog Input 1900837
Communications 1792281

 
PM8000 PM 5000

Phoenix Contact part #

Control Power 1745629
Digital Input 1900811
Digital Output 1900772
RS485 1900798
Voltage Input 1745645
 
PM5000 EX

Phoenix Contact part #

Control Power 1745629
Relays 1900798
Inputs/Outputs 1840405
Voltage Input 1745645
 
EGX100/EGX300 Conectors

Phoenix Contact part #

Control Power 1900772
Communications 1900808


Note: All these connectors are green

What is the 600 series adaptor to convert a 149 to 1 gang

 It is a PDL 538

What is the code for a 2-gang conversion plate for PDL 500/600 series?

Part code is PDL 538

What is the cable that goes to M238 and 499PWD01100

XBTZ9980 is the cable. EIO0000000414.05 is the User Guide.

What software is needed to program the M238?

SoMachine software is used to program the M238 PLC. Currently the latest version of SoMachine is 4.1.

Vijeo Designer and Vijeo XD Runtime year 2038 limitation

Since Vijeo Designer and Vijeo XD Runtime are currently both 32-Bit applications, they both will be affected by the year 2038 problem. That is, the date and time that the HMI can hold can only be upto the year 2038.

 

What are the dimensions for a 4FCC10?

286 MM Width, 258 MM height and 100 MM + wall thickness depth 

ION8650 Switchboard Meter Dimensions

Issue
Clarify the dimension of ION 8650 meter switchboard (285 x 228 x 163) on page-4 under mechanical characteristics of ION8650 datasheet. The (285 x 228 x 163) dimensions are not mentioned on page-8 of ION8650 datasheet.

Product Line
ION8650 Switchboard

Environment
Mechanical Dimensions

Cause
The datasheet showing the meter dimensions is misleading

Resolution
The correct dimensions are like those in the mechanical drawing: 226 mm high x 147 mm wide x 189 mm deep. The required cut-out will be, as on page 3, 149 mm wide x 230 mm tall.

Note: the mounting bolts are size 10-32.

Details Returned from APC Devices via Advanced Device Crawlers

Issue:

Details Returned from APC Devices via Advanced Device Crawlers

Product Line:

NetBotz

Environment:

NetBotz version 2 Advanced Device Crawlers.

Cause:

The following information can be queried via Advanced Device Crawlers for APC UPS systems assuming the APC DDF (Device Definition File) is installed on the NetBotz appliance and the APC UPS is SNMP enabled. Please note that not all information listed below is available on all APC models.

Resolution:

 
  • Battery Status
  • Time On Battery
  • Remaining Battery Capacity
  • Internal UPS Temperature
  • Battery Run Time Remaining
  • Battery Replace Indicator
  • Number of External Battery Packs
  • Number of Bad External Battery Packs
  • AC Input Phase
  • Utility Line Voltage
  • Maximum Utility Line Voltage Last Minute
  • Minimum Utility Line Voltage Last Minute
  • Input Frequency
  • Reason For Last Transfer to Battery Power
  • UPS Status
  • Output Phase
  • Output Voltage
  • Output Frequency
  • Current UPS Load - Rated Capacity
  • Current Load Draw on UPS
  • Nominal Output Voltage
  • Maximum Line Voltage Before Switching to Battery
  • Minimum Line Voltage Before Switching to Battery
  • Ambient Temperature Probe 1
  • Relative Humidity Probe 1
  • Ambient Temperature Probe 2
  • Relative Humidity Probe 2
  • Outlet Control
  • Overload Condition
  • Low Load Condition
  • Current Load
  • Outlet Control
  • MSP Outlet Control
  • Nominal Battery Voltage
  • Actual Battery Voltage
  • Battery Current
  • Total DC Current
  • DC Power Plant Model Number
  • Automatic Transfer Switch Model Number

What is the replacement for LXM23+ drives?

The Lexium 23+ Servo Drive offer, including BCH motors, cables and accessories is obsoleted and replaced with the new, higher performing Lexium 28 Servo Drive offer, including BCH2 motors, cables and accessories.

What are the dimensions of chassis PAN16 ?

Dimensions =  PAN16   - showing total width as 232 - Height = 432

Which Modem is recommended to be used with SoMachine V4.3 and the M238 controller?

The only Modem we tested with the M238 is the SR2MOD03.
 
With this modem you can do the following:
- Using GSM modem, it is possible to send/receive SMS
- Using SMS or RTC modem,
- it is possible to establish communication between two PLCs in order to exchange data via Modbus.
 
 

What is the air flow of the 6500ADS?

The air flow of the 6500ADS is 338 cubic meters per hour or 290 cubic meters per hour if you have a backdraught shutter fittered.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=6500ADS

Source upload/download is not possible. Why ?

Check the 2 following points :
- M238 needs to be stopped before attempting a source upload or download.
- Maximum project archive file ("Archive.prj") size is 0x90000 bytes (about 588 kB).

Was is the pin assignment of the CN3 connection for the RS485 port on Lexium 23?

Lexium 23 supports RS485 communication via the CN3 connection on the front of the drive.
Pin assignment of the RS485 is as follows.
Pin 4 = RS485+
pin 5 = RS485-

See attachment for greater details.

 

When does the "Broken Wire" fault become true for the 140ACI030 module?

When your input current drops below 2.8 mA the Status Word for the 140ACI03000 will indicate a "Broken Wire" condition.






R-71717
 

Can panel iPC MPCKT22NAX20N with Windows XP operating system be updated to Windows 7/10?

The Magelis MPCKT22NAX20N is an old product validated only with Windows XP operating system. Consequently, it is not compatible with Win 7 and Win 10. New iPC running Windows 7/10 has been used to replace the old one in order to apply the new operating systems. The closest replacement for MPCKT22NAX20N (313 × 239 × 103 mm) is HMIPUH6A0701 (313 × 239 × 60 mm), they have the same dimension where HMIPUH6A0701 is just thinner. Another option is the maintenance free version HMIPPF6A2701 (313 × 239 × 135 mm) which has SSD flash drive, built-in PCI expansion module, and DVD-RW drive. Both of the new modules have built in Windows 7 Ultimate 64-bit operating system. 

What is the code for the 240VAC Coil for the LC1D32 Contactor ?

Part Code = LXD1U7 
The LXD1U7 also fits the LC1D09 - D38 Contactors

Does Clipsal have a 1438 in 20 amp?

No, but we have a 438 in 20 amp or there is the 56 series which could do the job.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/20 

Can I connect a Magelis XBTRT511 to a telemacanique M238 PLC?

Yes, you can connect the XBTRT to one of the SL1 or SL2 on the M238 PLC.


Legacy KB System (APS) Data: RESL200147 V1.0, Originally authored by MiMe on 09/30/2009, Last Edited by MiMe on 09/30/2009
Related ranges: Magelis XBT N, R, RT

Maximum Size of SMS Message / Alert

Issue:

Maximum Size of SMS Message / Alert

Product Line:

NetBotz

Environment:

NetBotz SMS messaging via GSM modem

Cause:

Message size limitation..

Resolution:

The maximum size of an SMS text message sent via GSM is 160 single byte characters. Different carriers could potentially put lower limits.

Where can I view the current NetShelter cabinets, racks and accessories? I there a catalogue available?

Issue:
Is there a NetShelter Catalog available?

Product Line:
NetShelter
 
Environment:
All versions and serial ranges.
 
Cause:
Some customers may prefer a catalog version for reference.
 
Resolution:
Our current NetShelter product family of racks, cabinets and accessories can be viewed here: https://www.apc.com/tools/salestools/display.cfm?id=JCOS-7FNMFC 
First choose your country and you'll be forwarded the link on your local APC website. 

Which SCEM card is associated with each series of recloser/sectionalizer?

Product Line
Recloser

Resolution
Refer to the below table:

Resloser Series SCEM Card
N Series (up to 27kV) SCEM 11A
N Series (38 kV) SCEM 11C
U Series  SCEM 11B
W Series SCEM 11D
RL Series SCEM 12

Are the Easergy Flair 2xD Fault Passage Indicator devices UL listed?

Issue:
When looking at the UL listing for various Easergy Flair products, it may be noticed that the Flair 2xD fault passage indicator devices are not listed. 
 
Product Line:
Easergy Flair 2xD
 
Environment:
Easergy 21D
Easergy 22D
Easergy 23D
Easergy 23DM
 
Resolution:
The Easergy Flair 2xD products are not UL listed. 

What is the part number for the 230 switch board for Meter enclosure only ?

The part number for the 230 switch board for Meter enclosure only is - 230MV

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=230MV
User-added image

Are the LC1D40 thru LC1D150 Available With a Low Consumption DC Coil?

Issue: 
Looking for a higher amperage rated contactor with lox consumption dc coil.

Product Line:
Contactors and Starters

Environment:
D-Line Contactors
 
Resolution: 
No. Low consumption coils are available only on LC1D09 thru D38 contactors.

What are the dimensions for the MB Distribution Board?

The dimensions are as follows:

Depth = 235 mm ; Width = 580 mm

Please note the heights are different for different size board. For more information refer to the technical data on MB Distribution Boards (see attachment)

I believe someone has hacked my Wiser Link system, what do I do?

If you have any doubt regarding the integrity of your system, contact Schneider Electric Customer Care Center on 1300 369 233

If I face an issue during installation and commissioning whom should I contact?

Contact :partner.supportau@schneider-electric.com
CUSTOMER SERVICE 1300 369 233 (7:30AM TO 7:00PM (MON TO FRI) AEST)
TECHNICAL SUPPORT 1300 202 525 (7:30 AM to 7:00 PM MON TO FRI AEST)

For further information please visit Trade - Clipsal by Schneider Electric

Will the Altistart ATS46 work on 208 volts?

Issue: Will the Altistart ATS46 work on 208 volts?
 
Product Line: ATS46
 
Environment: All
 
Cause: N/A
 
Resolution: Yes that is in range for the the ATS46 family of softstarts.


 

Does the 56AI320 have round or flat pins?

The 56AI320 is not available with flat pins.

Some of the key features are:
  • 3 round pins
  • 204 mm Height x 101 mm Width x 138 mm Depth
  • 2.5 - 6 mm conductor terminal

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56AI320
 

 

Changing Power Flow Sign remotely on a Compact NSX

For remote sites there is a way of connecting remotely to a Micrologic unit to change the Power Flow Sign.
 
On page 118 of the following user guide is talks about Power Flow Sign and has a command code of 47240. This configures the power flow sign.

https://www.schneider-electric.com/en/download/document/DOCA0091EN/

Page 138 of the same guide explains how to do this configuration.

 

What type of communications connector is used by the Circuit Monitor 2000 (CM2) Portable's 232 port?

The CM2 Portable meter comes utilizes a RS232 DB25 connector. The user will need a custom PCMCOMM232 cable. Please see the following PINOUT


Legacy KB System (APS) Data: RESL206468 V1.0, Originally authored by MaTh on 10/24/2011, Last Edited by MaTh on 10/24/2011
Related ranges: CM2000 series

Are 23" mounting rails available for NetShelter SX cabinets?

Issue: 
Some equipment requires 23 inch wide mounting rails.

Product Line:
NetShelter SX

Environment:
All versions and serial ranges.

Cause:
A customer has 23 inch wide equipment and wants to mount it into a NetShelter SX cabinet.

Resolution: 

All 42U and 48U NetShelter SX 750 mm (30") wide cabinets are available with 23" mounting rails installed. These cabinets are not in stock, but they can be built to order.
  • For customers who already own a 42U 750mm wide SX cabinet with 19" mounting rails (AR3150 or AR3350) we offer sku AR7510. This is a set of four replacement 23" mounting rails, 42U.
  • We do not currently offer 48U 23" mounting rails as a stand alone sku, only pre-installed into the cabinet as described above.
  • We do not currently offer 45U 23" mounting rails. If you have an opportunity please check with your Schneider Electric representative to see if these can be provided as a Custom.
How to order a custom cabinet with 23" mounting rails installed: 
​If you buy direct from APC please contact your Sales Representative for price and availability. 
If you don't have an account with APC please contact APC Tech Support. We will give you a custom part number that can be quoted through a reseller or distributor. 

Compatibility Note: 23" wide mounting rails do not install into 600 mm (24") wide cabinets because the cabinets are not wide enough. 23" rackmount equipment requires a wider cabinet. 

I believe someone has hacked my Wiser Link Energy Monitor system, what do I do?

If you have any doubt regarding the integrity of your system, contact Schneider Electric Customer Care Center.

Contact :partner.supportau@schneider-electric.com
CUSTOMER SERVICE 1300 369 233 (7:30AM TO 7:00PM (MON TO FRI) AEST)
TECHNICAL SUPPORT 1300 202 525 (7:30 AM to 7:00 PM MON TO FRI AEST)
 

I have an LC1D TeSys D-Line contactor. Which are the coil terminals?

Issue:
I have an LC1D TeSys D-Line contactor.  Which are the coil terminals?

Product Line:
D Line contactors.

Environment:
Products sold in the United States.

Cause:
Product features.

Resolution:
The coil terminals are the ones labelled A1 and A2.


CTA-ID : 2011973

What is the telephone number for the Schneider Electric Industrial Repair Services?

Issue:
How to contact the service and repair group

Product Line:
All Schneider Electric Products.

Resolution:

The contact information for repair is;

Schneider Electric Industrial Repair Services
235 Burgess Rd.     Greensboro    NC 27409
U.S. Ph: 800.950.9550     FAX: 336.668.4878
Canada Ph: 877.677.8151     FAX: 859.817.3883
Email: industrialrepair@schneider-electric.com
Web: www.schneiderelectricrepair.com

Do you have a metal plug for the WMC532?

The metal plug that suits the WMC532 is the P532.

Some of the key features are:
  • 5 round pin-with plastic screw ring
  • Dimension 258 mm Height x 115 mm Width x 120 mm Depth

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P532
 


 

Verifying Digitally Signed Pictures with Version 2 Netbotz Appliances

Issue:

Verifying Digitally Signed Pictures with Version 2 Netbotz Appliances

Product Line:

NetBotz

Environment:

NetBotz version 2

Cause:

NetBotz has included a simple command line utility that enables you to verify that digitally signed M-JPEG (AVI) files have not been tampered with since they were generated by your NetBotz appliance.

Resolution:


The file name of the command line utility is:
avivrfy.bat

It is automatically installed and can be accessed from the Advanced View installation directory.

Command Usage:
avivrfy avifilename.avi

To verify multiple AVIs,:
avivrfy sample.avi sample1.avi sample2.avi”
 

How to convert floating point registers to an interger value in the Enercept Meter and Energy Meter?

Follow the steps below in the example to convert register values to an integer:


  • In this example register 287 has a value of 17395 and register 288 has a value of -22528. Register 287 is the upper 16 bit number and 288 is the lower 16 bit number.

    1) Convert 17395 and 22528 to binary numbers (add a 0 to the front of the number to make it 16 bits) and combine them (drop the negative sign from register 288). This will give you the following binary number:

     

    0 100001111110011 0 101100000000000

     

    2) Drop the 0 to the far left giving you 1000011111100110101100000000000

    3) Take the 8 bits on the far left and convert them to a decimal number:

    10000111 | 11100110101100000000000

    10000111 = 135

     

    4) Subtract 127 from the value that you got in step 3:

    135 - 127 = 8

     

    5) Take the part of the binary number that was not used in step 3

    11100110101100000000000

     

    6) Count over from the left the amount calculated in step 4. Drop off everything to the right of this.

    11100110

    7) Add a 1 to the front of that number.

    111100110

     

    8) Convert that number to decimal and this is the register value.

    486


    Original article#
    Date Created: November 11, 2007
    Last Revised: February 5, 2008
    Public
    Original Author: MN
    All content © 1992-2008 Schneider Electric


Legacy KB System (APS) Data: RESL190996 V1.0, Originally authored by PhHa on 02/06/2008, Last Edited by PhHa on 02/06/2008
Related ranges: PowerLogic Energy Meter, Enercept Meter

What is the ratings for a PDL 634L Rotary Dimmer Switch Leading Edge

Ratings:
Voltage 230 / 240V a.c.  50Hz
Maximum Load - 450W
Minimum Load - 20W

What is the ratings for a PDL 620K Rotary Dimmer Switch Leading Edge

Ratings are:
Voltage - 230 / 240V a.c.  50Hz
Maximum Load - 1000W
Minimum Load - 150W
Show More